{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.458156,"lon":-79.139083,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Indiana | |
Municipality: West Wheatfield Township | |
Operator Name: PENN VIEW EXPLORATION CORP | |
Well Pad ID: | |
Farm/Lease Name: HARBISON 2 | |
License Status: | |
Spud Date: 2012-10-22 | |
Permit Date: 2011-06-16 | |
Well Type: GAS | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Conservation: No | |
Latitude: 40.458156 | |
Longitude: -79.139083 |
Date | Event |
---|---|
2011-06-16 | New Permit Application |
2012-07-17 | Permit Renewal Application |
2012-10-22 | Performed Spud Operation |
2012-10-30 | Drilling Completion |
2013-06-19 | NEWLY DRILLED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | PENN VIEW EXPLORATION CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | PENN VIEW EXPLORATION CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | PENN VIEW EXPLORATION CORP | 17,395.00 | 306 | 0.00 | 0 | 0.00 | 0 |
2014 | PENN VIEW EXPLORATION CORP | 12,165.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | PENN VIEW EXPLORATION CORP | 7,567.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | PENN VIEW EXPLORATION CORP | 5,723.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2017 | PENN VIEW EXPLORATION CORP | 6,268.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | PENN VIEW EXPLORATION CORP | 5,395.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2113139 | Primary Facility | 2012-10-24 | Drilling/Alteration | No Violations Noted | First Energy was contracted by Penn View. Filter fence was located topographically down gradient of site pad. Permit and well sign were present. No freeboard issues were present. Conductor pipe (20”) set to 36 ft (sanded). Ground water protection pipe (13 3/8”) was set at 226 ft. Mine void was recorded at 181 feet. Cement basket was set at 136 feet. Stratigraphy consisted of coal, shale, sandstone, and limestone. During site inspection, no E&S or IW issues at the site. |
2113755 | Primary Facility | 2012-10-25 | Drilling/Alteration | No Violations Noted | First Energy was contracted by Penn View. Filter fence was located topographically down gradient of site pad. Permit and well sign were present. No freeboard issues were present. Conductor pipe (20”) set to 36 ft. (sanded). Mine protection pipe (13 3/8”) was set at 238 ft. and was cemented with 270 sacks of Type I with 7 bbl. return. Cement basket was set at 136 feet. Water was recorded at 320 ft. and 370 ft. depth. Groundwater protection pipe (9 5/8”) was going to be set at 462 feet. During site inspection, no E&S or IW issues at the site. |
2116889 | Primary Facility | 2012-10-25 | Routine/Complete Inspection | No Violations Noted | Site ID sign, drilling permit, and E&S plan all on-site and adequate. Drilling rig on-site and actively drilling at time of inspection.Operator did not install and implement second culvert closest to well site as indicated on E&S plan; however, since no evidence of accelerated erosion was noted, culvert did not appear to be necessary at this time.Department suggests that in the future, any changes to the E&S plan be marked on plan prior to construction. Department also recommends that Operator add rock to culvert inlet and outlet and clear sediment out of culvert pipe to ensure minimal erosion and optimal functioning of the BMP. |
2128002 | Primary Facility | 2012-12-28 | Routine/Complete Inspection | No Violations Noted | At time of inspection, well in production. Well tag present. Brine tank appeared sound. No E&S issues noted although site was snow-covered. Department recommends that Operator continues to monitor and maintain BMPs, access road, and well site as necessary. |
2215625 | Primary Facility | 2013-10-01 | Site Restoration | No Violations Noted | Restr inspt. At time of inspection, well equipped for production. Well tag present. Brine tank sound. Access road stable. |
2438024 | Primary Facility | 2015-11-13 | Routine/Complete Inspection | No Violations Noted | well as in production |