X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-063-37440

Well Details

Well ID: 37-063-37440
Loading map...
Country: United States
State: Pennsylvania
County: Indiana
Municipality: Brush Valley Township
Operator Name: WILMOTH INTERESTS INC
Well Pad ID:
Farm/Lease Name: HENRY 1A
License Status:
Spud Date: 2012-10-11
Permit Date: 2012-08-15
Well Type: GAS
Unconventional Well: N
Configuration: Deviated Well
Conservation: No
Latitude: 40.502058
Longitude: -79.051231

For data sources see[1][2][3]

Well History

Date Event
2012-08-15 New Permit Application
2012-10-09 Performed Spud Operation
2012-10-12 Drilling Completion
2012-10-30 Drilling Completion
2012-10-30 Perforation
2013-01-15 NEWLY DRILLED
2013-07-29 DRILLED DEEPER

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 WILMOTH INTERESTS INC 0.00 0 0.00 0 0.00 0
2013 WILMOTH INTERESTS INC 6,549.00 192 0.00 0 0.00 0
2014 WILMOTH INTERESTS INC 3,744.41 114 50.00 31 0.00 0
2015 WILMOTH INTERESTS INC 2,147.81 107 0.00 0 0.00 0
2016 WILMOTH INTERESTS INC 1,911.73 165 0.00 0 0.00 0
2017 WILMOTH INTERESTS INC 938.16 40 0.00 0 0.00 0
2018 WILMOTH INTERESTS INC 1,199.67 73 60.00 31 0.00 0
2019 WILMOTH INTERESTS INC 1,061.88 140 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 WILMOTH INTERESTS INC Fracing Fluid Waste 1,220.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095273
2012 WILMOTH INTERESTS INC Drilling Fluid Waste 1,220.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095273
2012 WILMOTH INTERESTS INC Drilling Fluid Waste 420.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095443
2013 WILMOTH INTERESTS INC Drilling Fluid Waste 140 Bbl CENT WASTE TRT FAC NPDES PA0095273
2013 WILMOTH INTERESTS INC Drilling Fluid Waste 320 Bbl CENT WASTE TRT FAC NPDES PA0095443
2013 WILMOTH INTERESTS INC Produced Fluid 130.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095443
2013 WILMOTH INTERESTS INC Produced Fluid 525 Bbl CENT WASTE TRT FAC NPDES PA0095273
2013 WILMOTH INTERESTS INC Produced Fluid 525.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273
2013 WILMOTH INTERESTS INC Drilling Fluid Waste 320.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095443
2013 WILMOTH INTERESTS INC Drilling Fluid Waste 140.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273
2013 WILMOTH INTERESTS INC Produced Fluid 130 Bbl CENT WASTE TRT FAC NPDES PA0095443
2014 WILMOTH INTERESTS INC Produced Fluid 188.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273
2014 WILMOTH INTERESTS INC Produced Fluid 188 Bbl CENT WASTE TRT FAC NPDES PA0095273
2014 WILMOTH INTERESTS INC Produced Fluid 75 Bbl CENT WASTE TRT FAC NPDES PA0095443
2014 WILMOTH INTERESTS INC Produced Fluid 75.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095443
2015 WILMOTH INTERESTS INC Produced Fluid 157 Bbl CENT WASTE TRT FAC NPDES PA0095273
2015 WILMOTH INTERESTS INC Produced Fluid 157.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273
2016 WILMOTH INTERESTS INC Produced Fluid 126.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273
2016 WILMOTH INTERESTS INC Produced Fluid 126 Bbl CENT WASTE TRT FAC NPDES PA0095273
2017 WILMOTH INTERESTS INC Produced Fluid 160.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273
2018 WILMOTH INTERESTS INC Produced Fluid 50.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273
2019 WILMOTH INTERESTS INC Produced Fluid 110.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2107329 Primary Facility 2012-10-12 Drilling/Alteration No Violations Noted
2107332 Primary Facility 2012-10-10 Drilling/Alteration No Violations Noted
2108339 Primary Facility 2012-10-10 Routine/Complete Inspection Violation(s) Noted UPDATE: 11/29/12 & 12/3/12-
2109419 Primary Facility 2012-10-16 Drilling/Alteration No Violations Noted
2114979 Primary Facility 2012-11-09 Drilling/Alteration No Violations Noted
2116259 Primary Facility 2012-11-08 Routine/Complete Inspection Violation(s) Noted At the time of this inspection, well site ID sign, ES plan, disposal plan and drilling permit present. Rig Skid since last inspection. Well drilled and fraced.ite has not yet been temporarily stabilized as a result violations will be issued for operators failure to properly temporarily stabilize well site after 4 days of cessation activity. Hence well site was not properly stabilized with an acceptable bmp and/or seed/mulch accelerated erosion occurred along access road and entrance to well site observed. Department noted that rock outlet has been washed out by recent heavy rains. It appears operator installed several sections of filter fence down gradient from well pad in order to help minimize the potential for accelerated sedimentation. In addition to filter fence, operator installed a drainage dike from the left side of the site thru the access road and down to the lower right side of access road, which appears to have increased the accelerated erosion concerns To date, operator has not yet provided evidence on depth of SHGWT.
2118510 Primary Facility 2012-11-21 Drilling/Alteration No Violations Noted
2121890 Primary Facility 2012-11-27 Compliance Evaluation No Violations Noted At time of inspection, well in production. Site ID sign, E&S plan, permit on-site. Brine tank appeared sound.
2128907 Primary Facility 2013-01-08 Follow-up Inspection Outstanding Violations - No Viols Req'd Well site ID sign, Es plan, and permit onsite. Well is drilled, equipped and in production (Rig Skid to 1A, previous well 1 plugged, with errected monument.) Brine tank appears sound.Access road and site snow covered; therefore, unable to determine stabilization condition and/or if any accelerated erosion or sedimentation concerns existed. It appears that operator has several bmp's installed, again due to snow coverage department is unable to adequately asses their condition and functioning ability. epartment is strongly recommending that operator continue to closely monitor and maintain site until final permanent restoration is achieved. One below grade, lined pit remains on site with contents
2131598 Primary Facility 2013-01-08 Bond Release In Compliance with Policy *RIG SKID* BOND RELEASE NOt APPLICABLE AT THIS TIME. CERTIFICATE OF PLUGGING RECEIVED 10/24/12.
2152163 Primary Facility 2013-03-20 Follow-up Inspection Outstanding Violations - No Viols Req'd At time of inspection, well in production. Site ID sign, E&S plan, permit on-site. Brine tank sound.
2162088 Primary Facility 2013-04-19 Follow-up Inspection Outstanding Violations - No Viols Req'd At time of inspection, well in production. Site ID sign, E&S plan, permit on-site. Brine tank sound.
2169397 Primary Facility 2013-05-17 Follow-up Inspection Outstanding Violations - No Viols Req'd Follow-up to violations issued under inspection record 2108339.
2169401 Primary Facility 2013-05-20 Follow-up Inspection Outstanding Violations - No Viols Req'd Follow-up to violations issued under inspection record 2108339.
2196655 Primary Facility 2013-07-30 Compliance Evaluation No Violations Noted CEI for violations issued under inspection record 2108339 for failure to construct pit so that bottom of pit is a minimum of 20 inches from SHGWT.
2196670 Primary Facility 2013-07-30 Site Restoration No Violations Noted Restr inspt. At time of inspection, well equipped for production. Brine tank sound. Entire length of access road rocked. No accelerated erosion or sedimentation issues observed.
2303679 Primary Facility 2014-09-12 Routine/Complete Inspection No Violations Noted
2591327 Primary Facility 2017-05-08 Routine/Complete Inspection No Violations Noted At time of inspection, well drilled and appears equipped for production. Well label present. Department recommends operator replace well tag on well in a legible, visible, and permanent manner per current regulations.

For data sources see[7]

References