Well ID: 37-063-37522 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.853167,"lon":-79.033311,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Indiana | |
Municipality: North Mahoning Township | |
Operator Name: CNX GAS CO LLC | |
Well Pad ID: 144923 | |
Farm/Lease Name: MARCHAND 3MHSUT | |
License Status: | |
Spud Date: | |
Permit Date: 2017-05-11 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: Yes | |
Latitude: 40.853167 | |
Longitude: -79.033311 |
Date | Event |
---|---|
2017-05-11 | New Permit Application |
2017-08-11 | Performed Spud Operation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2018-02-07 | 2018-02-21 | 13,227 | 15,368,500 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Other Chemical(s) | Listed Above | See Trade Name(s) List | Thiourea | 62-56-6 | 1 | 0.00000142 | 7.916 |
Distillates (petroleum), hydrotreated light | 64742-47-8 | 55 | 0.00478296 | 26692.5 | ||||
Alcohols, ethoxylated | 68439-50-9 | 5 | 0.00114337 | 6380.85 | ||||
DETA phosphonate | 15827-60-8 | 5 | 0.000156126 | 871.301 | ||||
Hexamethylene Triamine Penta(Methylene Phosphonic Acid) | 34690-00-1 | 5 | 0.000156126 | 871.301 | ||||
Alcohols, C10-16, ethoxylated | 68002-97-1 | 50 | 0.00007092 | 395.803 | ||||
Water | 7732-18-5 | 83 | 0.00446015 | 24891 | ||||
Formaldehyde | 50-00-0 | 1 | 0.00000142 | 7.916 | ||||
Methanol | 67-56-1 | 5 | 0.00000709 | 39.58 | ||||
Ammonium acetate | 631-61-8 | 13 | 0.00297275 | 16590.2 | ||||
Quarternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides |
68424-85-1 | 2.5 | 0.000134342 | 749.729 | ||||
Ethanol | 64-17-5 | 0.3 | 0.00001612 | 89.968 | ||||
Alcohols, ethoxylated | 68002-97-1 | 5 | 0.00114337 | 6380.85 | ||||
Alcohols, ethoxylated | 68551-12-2 | 5 | 0.00114337 | 6380.85 | ||||
Scale Inhibitor E | UPP | Scale Inhibitor | DETA phosphonate | 15827-60-8 | 5 | 0.000156126 | 871.301 | |
Hexamethylene Triamine Penta(Methylene Phosphonic Acid) | 34690-00-1 | 5 | 0.000156126 | 871.301 | ||||
Copolymer of Maleic and Acrylic Acid | 52255-49-9 | 20 | 0.000624504 | 3485.21 | ||||
HTL-200 Breaker | UPP | Breaker | Sodium chlorite | 7758-19-2 | 20 | 0.00004361 | 243.4 | |
Water | Consol | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 22.9808 | 128,250,000.0 | |
Unihib G | UPP | Acid inhibitor | Alcohols, C10-16, ethoxylated | 68002-97-1 | 50 | 0.00007092 | 395.803 | |
Methanol | 67-56-1 | 5 | 0.00000709 | 39.58 | ||||
Formaldehyde | 50-00-0 | 1 | 0.00000142 | 7.916 | ||||
Butyl diglycol | 112-34-5 | 75 | 0.000106384 | 593.705 | ||||
Thiourea | 62-56-6 | 1 | 0.00000142 | 7.916 | ||||
AP Breaker | UPP | Breaker | Ammonium Persulfate | 7727-54-0 | 100 | 0.00120798 | 6741.43 | |
Ceramic Proppant | Carbo Ceramics | Proppant | Ceramic materials and wares, chemicals | 66402-68-4 | 100 | 75.9287 | 423,739,000.0 | |
Aqucar 714 | UPP | Biocide | Glutaraldehyde | 111-30-8 | 14 | 0.000752315 | 4198.48 | |
Water | 7732-18-5 | 83 | 0.00446015 | 24891 | ||||
Ethanol | 64-17-5 | 0.3 | 0.00001612 | 89.968 | ||||
Quarternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides |
68424-85-1 | 2.5 | 0.000134342 | 749.729 | ||||
WGA-7 | UPP | Viscosifier | Distillates (petroleum), hydrotreated light | 64742-47-8 | 55 | 0.00478296 | 26692.5 | |
Guar Gum | 9000-30-0 | 55 | 0.00478296 | 26692.5 | ||||
Sand | UPP | Proppant | Crystalline Silica in the form of Quartz | 14808-60-7 | 99.9 | 0.908884 | 5,072,260.0 | |
Unislick ST50 | UPP | Friction reducer | Alcohols, ethoxylated | 68551-12-2 | 5 | 0.00114337 | 6380.85 | |
Petroleum distillates, hydrotreated light | 64742-47-8 | 30 | 0.0068602 | 38285.1 | ||||
Alcohols, ethoxylated | 68439-50-9 | 5 | 0.00114337 | 6380.85 | ||||
Alcohols, ethoxylated | 68002-97-1 | 5 | 0.00114337 | 6380.85 | ||||
Ammonium acetate | 631-61-8 | 13 | 0.00297275 | 16590.2 | ||||
HCL Acid (15%) | UPP | Acidizing | Hydrochloric Acid | 7647-01-0 | 15 | 0.00687447 | 38364.7 | |
HCL Acid (7.5%) | UPP | Acidizing | Hydrochloric Acid | 7647-01-0 | 7.5 | 0.00699541 | 39039.7 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2017 | CNX GAS CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2018 | CNX GAS CO LLC | 1,251,853.93 | 245 | 0.00 | 0 | 0.00 | 0 |
2019 | CNX GAS CO LLC | 1,403,410.55 | 363 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2017 | CNX GAS CO LLC | Drilling Fluid Waste | 840.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | ODNR 2015-29 |
2017 | CNX GAS CO LLC | Drilling Fluid Waste | 811.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | |
2017 | CNX GAS CO LLC | Produced Fluid | 165.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | ORDER 2016-29 |
2017 | CNX GAS CO LLC | Drill Cuttings | 3,050.37 Tons | LANDFILL | 100434 |
2018 | CNX GAS CO LLC | Produced Fluid | 3,589.40 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-17 |
2018 | CNX GAS CO LLC | Produced Fluid | 26,489.20 Bbl | REUSE (AT WELL PAD) | |
2018 | CNX GAS CO LLC | Produced Fluid | 7,718.47 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-21 |
2018 | CNX GAS CO LLC | Other Oil & Gas Wastes | 117.00 Bbl | REUSE (AT WELL PAD) | |
2018 | CNX GAS CO LLC | Produced Fluid | 37,608.29 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2018 | CNX GAS CO LLC | Produced Fluid | 1,040.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | ODNR 2015-29 |
2018 | CNX GAS CO LLC | Other Oil & Gas Wastes | 100.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-21 |
2018 | CNX GAS CO LLC | Unused Fracturing Fluid Waste | 9.36 Tons | RESIDUAL WASTE PROCESSING FACILITY | ORDER 2016-29 |
2018 | CNX GAS CO LLC | Produced Fluid | 535.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | |
2018 | CNX GAS CO LLC | Produced Fluid | 59.00 Tons | RESIDUAL WASTE PROCESSING FACILITY | 2014-541 |
2018 | CNX GAS CO LLC | Produced Fluid | 818.80 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018 | CNX GAS CO LLC | Other Oil & Gas Wastes | 140.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2018 | CNX GAS CO LLC | Synthetic Liner Materials | 53.54 Tons | LANDFILL | 100434 |
2018 | CNX GAS CO LLC | Produced Fluid | 154.84 Bbl | INJECTION DISPOSAL WELL | 34-119-28803 |
2019 | CNX GAS CO LLC | Produced Fluid | 25,870.41 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2019 | CNX GAS CO LLC | Other Oil & Gas Wastes | 80.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | CNX GAS CO LLC | Produced Fluid | 6,516.40 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-21 |
2019 | CNX GAS CO LLC | Other Oil & Gas Wastes | 220.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2019 | CNX GAS CO LLC | Produced Fluid | 3,090.10 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-17 |
2019 | CNX GAS CO LLC | Other Oil & Gas Wastes | 330.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019 | CNX GAS CO LLC | Produced Fluid | 126.67 Bbl | INJECTION DISPOSAL WELL | 34-119-28803 |
2019 | CNX GAS CO LLC | Produced Fluid | 177.00 Bbl | INJECTION DISPOSAL WELL | 34-119-28780 |
2019 | CNX GAS CO LLC | Produced Fluid | 11,254.70 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | CNX GAS CO LLC | Produced Fluid | 2,296.43 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2019 | CNX GAS CO LLC | Other Oil & Gas Wastes | 110.00 Tons | REUSE (AT WELL PAD) | |
2019 | CNX GAS CO LLC | Produced Fluid | 990.00 Bbl | REUSE (AT WELL PAD) | |
2019 | CNX GAS CO LLC | Produced Fluid | 85.00 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2019 | CNX GAS CO LLC | Produced Fluid | 14,909.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2626961 | Primary Facility | 2017-08-18 | Routine/Complete Inspection | No Violations Noted | Inspection conducted in response to spud notification for well 3MHSUT.
At time of inspection, well 3MHSUT surrounded by gate, cellar installed. Rig not on-site. Well 3I is drilled and appears equipped for production. |
2627340 | Primary Facility | 2017-08-17 | Drilling/Alteration | No Violations Noted | Pad was constructed. Sign located at entrance. No rig at the site. |
2629102 | Primary Facility | 2017-08-25 | Drilling/Alteration | No Violations Noted | Conductor and cellar in place, no rig on site. |
2642998 | Primary Facility | 2017-10-03 | Routine/Complete Inspection | No Violations Noted | Inspection conducted in response to resumption of drilling for well 3MHSUT. Rig on-site.
At time of inspection, operator representative Steve Jager on-site. Per Mr. Jager, the surface casing was completed last night. Drilling is to resume shortly. The Department notified Mr. Jager of the recommendations listed below. Mr. Jager agreed to ensure these recommendations are implemented promptly and as appropriate. Well 3I is drilled and appears equipped for production. |
2645344 | Primary Facility | 2017-10-10 | Drilling/Alteration | No Violations Noted | 10/10/17 - drilling at 8146' to set 2nd intermediate csg. |
2650075 | Primary Facility | 2017-10-20 | Routine/Complete Inspection | No Violations Noted | At time of inspection, operator representative Steve Jager on-site. Per Mr. Jager, the rig is preparing to drill another 200 feet on well 3MHSUT prior to coring.
Well 3I is drilled and appears equipped for production. Inspection conducted with WQS Cindy Witham. |
2656312 | Primary Facility | 2017-10-25 | Routine/Complete Inspection | No Violations Noted | At time of inspection, rig awaiting for the arrival of additional equipment prior to the commencement of coring on well 3MHSUT according to operator representative Steve Jager.
Well 3I is drilled and appears equipped for production. |
2665407 | Primary Facility | 2017-11-30 | Routine/Complete Inspection | No Violations Noted | At time of inspection, per on-site operator DSM, the rig is currently tripping pipe on well 3MHSUT.
Well 3I is drilled and appears equipped for production. Well tag present, legible. |
2675395 | Primary Facility | 2017-12-28 | Routine/Complete Inspection | No Violations Noted | At time of inspection, rig is not on-site. Well 3MHSUT was spudded on 8/11/2017, not yet frac'd. Well 3MHSUT is located in a cellar that contains what appears to possibly be water; the Department observed rapid bubbling in this fluid that appears to be originating from the well. The Department immediately forwarded this potential concern to OGI J. Branan for follow-up as appropriate.
Well 3I is drilled and appears equipped for production. Well tag present, legible. |
2675571 | Primary Facility | 2017-12-28 | Routine/Complete Inspection | No Violations Noted | Well plugged. |
2675586 | Primary Facility | 2017-12-28 | Routine/Complete Inspection | No Violations Noted | This well drilled but not stimulated. Spoke w/CNX Rep. E. Gamble about flange leaking. Gamble is sending a crew for repair. |
2682913 | Primary Facility | 2018-01-10 | Routine/Complete Inspection | No Violations Noted | Inspection is in response to a well cellar leak reported to CNX by the Department on 12/28/2017/8.
Inspection conducted with MRPS Doug Catalano. CNX representatives present were Ryan Coffman, John Hardcastle, Spencer Johnson along with a representative from Cameron Well Heads. Well is being prepped for stimulation activities. All the fluid has been removed from the cellar. Operator reports that the 9 5/8¿ x 5 ½¿ annular pressure is ~2200 psig. 13 3/8¿ x 9 5/8¿ annular pressure is ~400 psig. With the current well head configuration, we are unable to monitor 18 5/8¿ x 13 3/8¿ annulus. Additionally, no one could enter the cellar as it is considered a confined space. With the potential for gas to be present, the cellar atmosphere would need to be evacuated and monitored continually prior to entering. On 12/29/2017, prior to removing the cellar fluids, CNX blew down the 13 3/8¿ x 9 5/8¿ annulus (low volume reported). Gas expression remained present in the cellar after blowing down pressure. Based upon this i |
2683450 | Primary Facility | 2018-01-18 | Routine/Complete Inspection | No Violations Noted | At time of inspection, rig is not on-site. Well 3MHSUT was spudded on 8/11/2017, not yet frac'd.
Well 3I is drilled and appears equipped for production. |
2693789 | Primary Facility | 2018-02-12 | Routine/Complete Inspection | No Violations Noted | At time of inspection, stimulation activities ongoing for well 3MHSUT.
Well 3I is drilled and appears equipped for production. |
2702531 | Primary Facility | 2018-03-07 | Routine/Complete Inspection | No Violations Noted | At time of inspection, preparation for flaring operations are ongoing for well 3MHSUT.
Well 3I is drilled and appears equipped for production. |
2709967 | Primary Facility | 2018-03-19 | Routine/Complete Inspection | No Violations Noted | At time of inspection, flaring operations are actively ongoing for well 3MHSUT.
Well 3I is drilled and appears equipped for production. Accompanied by operator consultant during this inspection. |