37-065-26359

Well Details

Well ID: 37-065-26359
Loading map...
Country: United States
State: Pennsylvania
County: Jefferson
Municipality: Snyder Township
Operator Name: FLATIRONS DEVELOPMENT LLC
Well Pad ID: 147212
Farm/Lease Name: BRANDON DAY 2 H
License Status: PLUGGED & ABANDONED
Spud Date:
Permit Date: 2008-07-03
Well Type: MULTIPLE WELL BORE TYPE
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 41.226603
Longitude: -78.714958

For data sources see[1][2][3]

Well History

Date Event
2008-07-03 New Permit Application
2009-01-20 Performed Spud Operation
2009-01-27 Drilling Completion
2010-02-18 NEWLY DRILLED
2010-04-12 New Permit Application
2014-03-20 Drilling Completion
2016-01-27 FULLY PLUGGED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 FLATIRONS DEVELOPMENT LLC 0.00 0 0.00 0 0.00 0
2011 FLATIRONS DEVELOPMENT LLC 0.00 0 0.00 0 0.00 0
2012 FLATIRONS DEVELOPMENT LLC 0.00 0 0.00 0 0.00 0
2013 FLATIRONS DEVELOPMENT LLC 0.00 0 0.00 0 0.00 0
2014 FLATIRONS DEVELOPMENT LLC 0.00 0 0.00 0 0.00 0
2015 FLATIRONS DEVELOPMENT LLC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 FLATIRONS DEVELOPMENT LLC Drilling Fluid Waste 390.00 Bbl LANDFILL THR029
2014 FLATIRONS DEVELOPMENT LLC Drilling Fluid Waste 50.00 Bbl INJECTION DISPOSAL WELL 34-007-24355

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1834204 Primary Facility 2009-10-08 Routine/Complete Inspection No Violations Noted
1855854 Primary Facility 2010-01-13 Routine/Complete Inspection No Violations Noted
1874689 Primary Facility 2010-04-05 Routine/Complete Inspection No Violations Noted
1878719 Primary Facility 2010-04-15 Routine/Complete Inspection No Violations Noted
1887297 Primary Facility 2010-05-25 Routine/Complete Inspection No Violations Noted
1893311 Primary Facility 2010-06-22 Routine/Complete Inspection No Violations Noted
1894460 Primary Facility 2010-06-28 Routine/Complete Inspection No Violations Noted
1898588 Primary Facility 2010-07-16 Routine/Complete Inspection No Violations Noted
1904068 Primary Facility 2010-08-09 Routine/Complete Inspection No Violations Noted
1994995 Primary Facility 2011-08-10 Routine/Complete Inspection No Violations Noted
1995792 Primary Facility 2011-08-10 Routine/Complete Inspection Violation(s) Noted
1998316 Primary Facility 2011-08-24 Compliance Evaluation No Violations Noted
2012793 Primary Facility 2011-10-19 Routine/Complete Inspection No Violations Noted
2298637 Primary Facility 2014-08-19 Plugging(Includes Plugged/Mined Through) No Violations Noted

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1995792 617791 08/10/2011 2011-08-10 102.4INADPLN - E&S Plan not adequate Administrative Plan drawing not accurate.
1995792 617792 08/10/2011 2011-08-10 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation. Administrative Culvert outlet not adequately stabilized.
1995792 617793 08/10/2011 2011-08-10 402CSL B - Failure to meet requirements of permit, rules and regulations, or order of DEP. Environmental Health & Safety Failure to meet requirements of ESCGP-1

For data sources see[7]

References