If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-081-20132 | ![]() Sorry, we have no imagery here. Sorry, we have no imagery here. ![]() |
Country: United States | |
State: Pennsylvania | |
County: Lycoming | |
Municipality: Franklin Township | |
Operator Name: EXCO RESOURCES PA LLC | |
Well Pad ID: 149330 | |
Farm/Lease Name: SNYDER UNIT 1 | |
License Status: INACTIVE | |
Spud Date: 2009-06-03 | |
Permit Date: 2008-12-30 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Vertical Well | |
Conservation: No | |
Latitude: 41.243262 | |
Longitude: -76.571013 |
Date | Event |
---|---|
2008-12-30 | New Permit Application |
2009-05-29 | Performed Spud Operation |
2009-06-20 | Drilling Completion |
2009-07-20 | Perforation |
2009-07-20 | Performed Stimulation |
2009-11-23 | Newly Drilled |
2014-06-09 | Inactive Well Request Granted |
2017-08-31 | Begin Plugging |
2017-09-13 | Finished Plugging |
For data sources see[4]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2009-07-20 | Sand | 0 | 0 | 0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2005 | EXCO RESOURCES PA INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2006 | EXCO RESOURCES PA INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2007 | EXCO RESOURCES PA INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2008 | EXCO RESOURCES PA INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2009 | EXCO RESOURCES PA INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2010 | EXCO RESOURCES PA INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | EXCO RESOURCES PA INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | EXCO RESOURCES PA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | EXCO RESOURCES PA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | EXCO RESOURCES PA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | EXCO RESOURCES PA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | EXCO RESOURCES PA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | EXCO RESOURCES PA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2009 | EXCO RESOURCES PA INC | Fracking Fluid | 530.00 Bbl | Other | |
2009 | EXCO RESOURCES PA INC | Fracking Fluid | 460.00 Bbl | Brine or Industrial Waste Treatment Plt | PA0101508 |
2009 | EXCO RESOURCES PA INC | Drilling | 490.00 Bbl | Brine or Industrial Waste Treatment Plt | PA0101508 |
2010 | EXCO RESOURCES PA INC | Drilling Fluid Waste | 245.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2010 | EXCO RESOURCES PA INC | Fracing Fluid Waste | 265.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0027057 |
2010 | EXCO RESOURCES PA INC | Fracing Fluid Waste | 230.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2017 | EXCO RESOURCES PA LLC | Spent Lubricant Waste | 83.24 Bbl | LANDFILL | 301358 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1760520 | Primary Facility | 2009-01-06 | Routine/Complete Inspection | Violation(s) Noted | |
1764745 | Primary Facility | 2009-01-26 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | |
1769057 | Primary Facility | 2009-02-05 | Routine/Complete Inspection | No Violations Noted | |
1840703 | Primary Facility | 2009-11-04 | Routine/Complete Inspection | De minimus Violations Noted | minor E&S issues on fill slope. MAB |
1856836 | Primary Facility | 2010-01-13 | Routine/Partial Inspection | No Violations Noted | |
2477422 | Primary Facility | 2016-04-19 | Routine/Complete Inspection | No Violations Noted | Inspection to investigate WQS Ben Bahner's observation that gas was flowing from a hissing annular vent. At the time of my inspection, gas was hissing out of the only visible vent. Field monitoring yielded 100% methane. Tenative ID of vent was production x intermediate annulus. |
2477424 | Primary Facility | 2016-04-21 | Follow-up Inspection | No Violations Noted | Arrived @ 09:00. The purpose of this follow-up inspection was to meet with Bird Smith (EXCO) and measure the flow rate through the annular vent. Bird and I fitted a 1/8” office plate restriction to the annulus at ¿ 09:05. The magnehelic differential pressure gauge stabilized with a reading of 7.4” water at 09:41. This reading converted to ¿ 1400 scf/day. The composition of this gas was 100% methane, (field monitoring using an Altair 5X gas meter). The Snyder Unit #1 well has been on regulatory inactive status since 06/09/2014. The Application for Inactive Status, submitted on 06/03/2013, lists the surface casing annulus pressure as: 0 psi. The discrepancy between the conditions observed during this inspection and the conditions described in the Inactive Status Application could be due to a: mistake in the data entered or a change in the well conditions. I discussed this with Bird. Left location @ 10:10 |
2478304 | Primary Facility | 2016-04-25 | Follow-up Inspection | No Violations Noted | Arrived @ 12:30. Weather sunny, windy. The purpose of this follow-up inspection was to try to check for gas at ground level adjacent to the well head. I sprayed a solution of Dawn dish soap and water on the gravel around the well casing. The solution disappeared. I also set a gas collection device in the gravel to see if measureable methane were being emitted. An Altair 5X gas meter calibrated on 4/25/16 gave a field reading of 3% methane. The reading, however, was not accompanied by a detection with the LEL sensor on the meter, and was accompanied by a rising CO reading, shedding doubt on the field measurement. Contacted EXCO to suggest they investigate further. Left location @ 13:20. |
2478317 | Primary Facility | 2016-04-19 | Routine/Complete Inspection | No Violations Noted | The Snyder Unit 1 well (081-20132) was being vented from the only visible annulus vent on the well head. This issue will be forwarded to the O&G Insp. for investigation. The well pad area has been reduced to just a small gravel area around the well. The ESX12-081-0078 was issued on 7/02/2012 but was never implemented. The well pad was constructed and the well was drilled and completed in 2009. The well site was also reduced to its current size before the ESCGP was issued. The well site is not connected to any larger site so the ESCGP was never required. Currently, the Well Site Compliance Information Request reply (submitted 9/21/2015) states the well pad is compliant with restoration requirements since the well pad has been reclaimed. I agree that the well pad area was restored to a very small footprint around the well before inactive status was granted but a Well Site Restoration Report was not received. Please provide the Well Site Restoration Report since the well site has been restored |
2537897 | Primary Facility | 2016-11-03 | Follow-up Inspection | No Violations Noted | Arrived @ 10:00. Weather cloudy, cool. The purpose of this follow-up inspection was to check on combustible gas concentrations at the annular vent to this well. An Altair 5X gas meter calibrated on 10/3/16 was used to detect 100% combustible gas/volume at the ½” stainless steel vent line.
It is worth noting that the Snyder Unit 1 well is on regulatory inactive status well. At the time of application, the venting of combustible gas was not described. Based on an email dated 11/1/2016, EXCO plans to plug this well (see attached). No violations noted at the time of the inspection. Left @ 10:20. 11/1/16 Hi Becky, Sorry for the delay. We intend to move forward with plugging the Snyder well. We will forward the plugging procedure to you this week for your review. With regard to schedule, we are trying to line up a workover rig. Once we have that finalized, then we will set the date and let you know as well as submit the NOI and notification letters as required. Thanks, Brian E. Rushe, P.E. Regulatory |
2564341 | Primary Facility | 2017-02-22 | Routine/Complete Inspection | No Violations Noted | : Arrived @ 11:00. Weather warm, cloudy, with some minor rain. cloudy, cool. The purpose of this follow-up inspection was to check on combustible gas concentrations at the annular vent to this well. An Altair 5X gas meter calibrated on 2/22/17 was used to detect 100% combustible gas/volume at the ½” stainless steel vent line to the 8-5/8” x 4-1/2” annulus. Previous inspections have noted the flow of combustible gas (first inspection: 4/19/16, IR# 2477422). On 4/21/16, this flow rate was measured to be ¿ 1400 scf/day.
It is worth noting that the Snyder Unit 1 well is a regulatory inactive status well. At the time of application, the venting of combustible gas was not described, suggesting that conditions at the well have changed. Previously, EXCO informed the Department that it plans to plug this well. The Department is awaiting a plugging proposal.. Left @ 11:36. |
2584606 | Primary Facility | 2017-04-13 | Routine/Complete Inspection | No Violations Noted | Arrived @ 15:00. Weather warm. The purpose of this follow-up inspection was to check on combustible gas concentrations at the annular vent to this well. An Altair 5X gas meter calibrated on 4/11/17 was used to detect 100% combustible gas/volume at the ½” stainless steel vent line to the 8-5/8” x 4-1/2” annulus. Previous inspections have noted the flow of combustible gas (first inspection: 4/19/16, IR# 2477422). On 4/21/16, this flow rate was measured to be ¿ 1400 scf/day.
It is worth noting that the Snyder Unit 1 well is a regulatory inactive status well. At the time of application, the venting of combustible gas was not described, suggesting that conditions at the well have changed. Previously, EXCO informed the Department that it plans to plug this well. The Department is awaiting a plugging proposal.. Left @ 15:24. |
2624192 | Primary Facility | 2017-08-08 | Routine/Complete Inspection | No Violations Noted | Routine Inspection of the Snyder 1 well (081-20132). Production tree on well, shut in. 8 5/8” csg vented. No obvious issues observed. |
2631567 | Primary Facility | 2017-08-31 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Rig on location for P&A. Reviewed procedure w/ Companyman. CIBP will be set later today @ 6375'. Cementers got delayed, expected to cap CIBP w/ cmt. The rig plans to recover ~ 4000' of 4 1/2" csg and complete the rest of the P&A n accordance to the regulations. Operator is plugging as a Non-Coal well. No Issues |
2633213 | Primary Facility | 2017-09-07 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Service rig on location for plug and abandonment. Operator is plugging as Non-Coal. Reviewed and discussed the procedure with the company man. CIBP has been set at 6375', above perforated interval. Cementers spotted cmt on top of CIBP. 4 1/2" csg is dead. Getting ready to run back in hole w/ TBG and tag. No obvious issues |
2635324 | Primary Facility | 2017-09-13 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | On location 8 am. Crew rigging down equipment. Visual inspection of plugged well-- casing full of gel, no bubbling, no gas detected. Spoke w/ Companyman, the crew successfully isolated bottomhole, recovered 4 1/2", and plugged remainder of well in accordance w/ regs. The well will be cut, capped, marked, and buried. GPS location and photo attached. No issues |
2638468 | Primary Facility | 2017-09-19 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | At the time of the inspection, the well was plugged and buried below plow depth. No other people or active operations were noted onsite. Waste onsite remains sealed in roll-off boxes on containment. The site has not yet been restored. No violations noted. |
2640291 | Primary Facility | 2017-09-27 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Routine inspection of a plugged well, post-plugging. The well has now been cut, capped, and covered with gravel. I stood above the plugged well and checked for gas at ground level, monitored for several minutes in multiple spots, none detected. No obvious issues. |
2722643 | Primary Facility | 2018-04-25 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | A routine inspection of this plugged, unconventional well was conducted April 25th, 2018. The well was plugged at the end of last year and is now cut below grade. The pad has since been reclaimed. No open holes, discharges, gas, or other plugging-related issues were observed at surface above the buried well's location at this time. |
2801582 | Primary Facility | 2018-11-09 | Routine/Complete Inspection | No Violations Noted | Site restored. No post plugging restoration report received by the DEP.
Please submit the Post Plugging Restoration Report a.s.a.p. |
2841645 | Primary Facility | 2019-02-05 | Routine/Complete Inspection | No Violations Noted | EXCO Resources (PA) LLC has submitted a notice of termination (NOT) to the Department for the Snyder Pad covered under ESX12-081-78. The Department received the NOT on January 11, 2019.
Department representative Jared Jacobini conducted a restoration site inspection at the above listed site on February 5, 2019. The site sign, emergency response plan, ESCGP, and weekly E&Sinspection log were onsite for review. No E&Sissues were observed during the time of the inspection. The former well pad was constructed on moderately sloped ground. Overall, the site is stable and well vegetated exceeding 70% uniform, perennial, vegetative cover. The former well pad site "open field area" meets the definition of permanent stabilization. To approve the request for an NOT, the document must be signed and stamped by a licensed professional - Page 2, block #5 "Final Certification Of Licensed Professional". This was not completed on the NOT request form. The existing gravel access road has not been removed. The site signs and |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1760520 | 554143 | 01/06/2009 | 2009-01-06 | 102.4INADPLN - E&S Plan not adequate | Administrative |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
554143 | 242042 | NOV - Notice of Violation | Comply/Closed | 2009-02-05 |
For data sources see[8]