Well Details

Well ID: 37-081-20244
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Penn Township
Operator Name: EXCO RESOURCES PA LLC
Well Pad ID: 149017
Farm/Lease Name: PATTERSON UNIT 5H
License Status:
Spud Date:
Permit Date: 2009-12-22
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.275730
Longitude: -76.650167

For data sources see[1][2][3]

Well History

Date Event
2009-12-22 New Permit Application
2010-04-09 Performed Spud Operation
2010-05-05 Drilling Completion
2010-08-16 DEVIATED
2010-11-12 Perforation

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2010 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2011 EXCO RESOURCES PA LLC 6,166.57 31 0.00 0 0.00 0
2012 EXCO RESOURCES PA LLC 39,027.00 31 0.00 0 0.00 0
2013 EXCO RESOURCES PA LLC 110,484.00 92 0.00 0 0.00 0
2014 EXCO RESOURCES PA LLC 19,259.00 61 0.00 0 0.00 0
2015 EXCO RESOURCES PA LLC 94,536.00 86 0.00 0 0.00 0
2016 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2017 EXCO RESOURCES PA LLC 1,559.00 9 0.00 0 0.00 0
2018 EXCO RESOURCES PA LLC 257.00 2 0.00 0 0.00 0
2019 EXCO RESOURCES PA LLC 103,427.00 77 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 CHIEF OIL & GAS LLC Produced Fluid 1,037.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2010 CHIEF OIL & GAS LLC Fracing Fluid Waste 6,666.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0008451
2011 EXCO RESOURCES PA LLC Produced Fluid 43.40 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 EXCO RESOURCES PA LLC Produced Fluid 1,086.16 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 EXCO RESOURCES PA LLC Produced Fluid 1,043.46 Bbl STORAGE PENDING DISPOSAL OR REUSE
2012 EXCO RESOURCES PA LLC Produced Fluid 8,305.06 Bbl REUSE OTHER THAN ROAD SPREADING
2013 EXCO RESOURCES PA LLC Produced Fluid 288.09 Bbl STORAGE PENDING DISPOSAL OR REUSE
2013 EXCO RESOURCES PA LLC Produced Fluid 2.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC009
2013 EXCO RESOURCES PA LLC Produced Fluid 4,372.52 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2013 EXCO RESOURCES PA LLC Produced Fluid 438.56 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EXCO RESOURCES PA LLC Produced Fluid 15.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC024
2014 EXCO RESOURCES PA LLC Produced Fluid 27.40 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2014 EXCO RESOURCES PA LLC Produced Fluid 23.80 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014 EXCO RESOURCES PA LLC Produced Fluid 1,338.70 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EXCO RESOURCES PA LLC Produced Fluid 1,665.20 Bbl STORAGE PENDING DISPOSAL OR REUSE
2015 EXCO RESOURCES PA LLC Produced Fluid 109.80 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2015 EXCO RESOURCES PA LLC Produced Fluid 1,265.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC009
2015 EXCO RESOURCES PA LLC Produced Fluid 6,084.20 Bbl REUSE OTHER THAN ROAD SPREADING
2017 EXCO RESOURCES PA LLC Produced Fluid 147.40 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2019 EXCO RESOURCES PA LLC Produced Fluid 6,764.50 Bbl REUSE (AT WELL PAD)

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1891006 Primary Facility 2010-05-20 Drilling/Alteration Viol(s) Noted & Immediately Corrected well id sign ordered will put up as soon as it gets in
1929616 Primary Facility 2010-11-15 Follow-up Inspection No Violations Noted
1941448 Primary Facility 2011-01-05 Routine/Complete Inspection No Violations Noted
1961807 Primary Facility 2011-03-30 Routine/Partial Inspection No Violations Noted
1965851 Primary Facility 2011-04-14 Routine/Complete Inspection No Violations Noted
1966508 Primary Facility 2011-04-18 Routine/Complete Inspection No Violations Noted
2060363 Primary Facility 2012-04-17 Routine/Complete Inspection No Violations Noted
2062945 Primary Facility 2012-04-25 Routine/Complete Inspection No Violations Noted
2092502 Primary Facility 2012-08-15 Routine/Complete Inspection No Violations Noted
2116533 Primary Facility 2012-11-15 Incident- Response to Accident or Event Violation(s) Noted Penn Twp.
2120895 Primary Facility 2012-12-04 Compliance Evaluation Outstanding Violations - No Viols Req'd
2437797 Primary Facility 2015-12-30 Routine/Complete Inspection No Violations Noted Arrived @ 12:53. Weather: foggy, cloudy, some fine drizzle. Four wells, formerly in production, were shut-in. Lease tender Bobby Hamel was onsite pumping rain water out of the containment around the produced water tank. All well cellars were filled with gravel. There were two open annular vents at each well. The 13-3/8” x 9-5/8” was vented with a 1” pipe. The 9-5/8” x 5-1/2” annulus was vented with a 2” pipe. The annuli were monitored with an Altair 5X gas meter calibrated on 12/28/15.
2543927 Primary Facility 2016-12-08 Routine/Complete Inspection No Violations Noted Routine Inspection; 12/8/2016. I entered the location at 09:57 and began the inspection. At the time of the inspection, the Patterson Unit 1H (081-20240), 2H (081-20241), 4H (081-20243), and 5H (081-20244) wells were in production. The well pad area was well vegetated and can be considered permanently stabilized. The well site has not been restored and the Well Site Compliance Information Request reply (submitted 9/21/2015) says the well site has been restored and the Notice of Termination was to be submitted in September of 2015. The well pad remains at its original size and the site currently does not conform to the permitted restoration plan. The original ESCGP has been expired since 11/23/2014.
The Department considers a well site to be restored under Section 3216(c) of the 2012 Oil and Gas Act when the oil or gas owners or operators meet the following:
1. All permanent post construction stormwater control features as identified in the Post Construction Stormwater Management/Site Restoration Pla
2584380 Primary Facility 2017-03-28 Routine/Complete Inspection No Violations Noted Arrived @ 10:00. Weather: cloudy, warm, light rain. There are 4 wells capable of production on location. At the time of my inspection the 1H and 2H were in production, 4H and 5H were locked and shut-in. There were 3 annular vent pipes at each well. All well cellars were filled with gravel. The annuli for the 2H were configured differently, but for the other wells, the 20” x 13-3/8” and 13-3/8” x 9-5/8” were open and the 9-5/8” x 5-1/2” was plumbed to a dump line. The annuli were monitored with an Altair 5X gas meter calibrated on 03/28/17. No combustible gas was detected at the annuli of the: 1H, 4H, and 5H. The annuli for the 2H were linked together and it was not possible at the time of my inspection to test for gas.
2694390 Primary Facility 2018-02-14 Routine/Complete Inspection No Violations Noted Weather was 30° and cloudy at time of inspection. Met with lease operator Bobby Hamel on location at time of inspection. Well had an analog pressure gauge attached above the swab valve. Pressure was approximately 320 psi at time of inspection. There were three annulus vents plumbed to surface. The 5 1/2 x 9 5/8 annulus vent was plumbed across location to the produced water tanks. The 9 5/8 x 13 3/8 and 13 3/8 x 20 annulus vents were open and 0% combustible gas was detected at time of inspection. No violations were noted at time of inspection.
2832715 Primary Facility 2019-01-28 Routine/Complete Inspection No Violations Noted On January 28, 2019, Department representative Brad Kline conducted a routine site inspection at EXCO Resources, LLC. Patterson Unit 1 pad. Site inspection log was onsite for review. No E&S issues were observed during the time of inspection. The site is stable and well vegetated meeting the 70% uniform, perennial, vegetative cover.

There are a total of 4 producing wells located on this well pad. All wells are tagged with API/well permit numbers. Well cellars are filled in with gravel. There are 4 GPU’s and 2 steel vertical production fluids tanks onsite. Production fluid tanks and GPUs were stationed in separate secondary containment.

No violations noted. The Department recommends submitting a Notice of Termination and a Post-Drilling Well Site Restoration Report when the criteria are met and weather conditions permit.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1891006 589351 05/20/2010 2010-05-20 201G - Failure to post permit number, operator name, address, telephone number in a conspicuous manner at the site during drilling Administrative
2116533 653903 11/15/2012 2012-11-15 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety Flowback and diesel fuel spill to south ditch of Patterson well pad. - Analyticals recd 4/25/2013, review by OG program 6/5/2013
2116533 653904 11/15/2012 2012-11-15 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. Environmental Health & Safety Flowback and diesel fuel spill to south ditch of Patterson well pad. - Analyticals recd 4/25/2013, review by OG program 6/5/2013
2116533 653905 11/15/2012 2012-11-15 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. Environmental Health & Safety Flowback and diesel fuel spill to south ditch of Patterson well pad. - Analyticals recd 4/25/2013, review by OG program 6/5/2013

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
653903 290649 NOV - Notice of Violation Comply/Closed 2013-06-05
653904 290649 NOV - Notice of Violation Comply/Closed 2013-06-05
653905 290649 NOV - Notice of Violation Comply/Closed 2013-06-05

For data sources see[7]