If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-081-20244 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.27573,"lon":-76.650167,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Lycoming | |
Municipality: Penn Township | |
Operator Name: EXCO RESOURCES PA LLC | |
Well Pad ID: 149017 | |
Farm/Lease Name: PATTERSON UNIT 5H | |
License Status: | |
Spud Date: | |
Permit Date: 2009-12-22 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.275730 | |
Longitude: -76.650167 |
Date | Event |
---|---|
2009-12-22 | New Permit Application |
2010-04-09 | Performed Spud Operation |
2010-05-05 | Drilling Completion |
2010-08-16 | DEVIATED |
2010-11-12 | Perforation |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2009 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2010 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | EXCO RESOURCES PA LLC | 6,166.57 | 31 | 0.00 | 0 | 0.00 | 0 |
2012 | EXCO RESOURCES PA LLC | 39,027.00 | 31 | 0.00 | 0 | 0.00 | 0 |
2013 | EXCO RESOURCES PA LLC | 110,484.00 | 92 | 0.00 | 0 | 0.00 | 0 |
2014 | EXCO RESOURCES PA LLC | 19,259.00 | 61 | 0.00 | 0 | 0.00 | 0 |
2015 | EXCO RESOURCES PA LLC | 94,536.00 | 86 | 0.00 | 0 | 0.00 | 0 |
2016 | EXCO RESOURCES PA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | EXCO RESOURCES PA LLC | 1,559.00 | 9 | 0.00 | 0 | 0.00 | 0 |
2018 | EXCO RESOURCES PA LLC | 257.00 | 2 | 0.00 | 0 | 0.00 | 0 |
2019 | EXCO RESOURCES PA LLC | 103,427.00 | 77 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2010 | CHIEF OIL & GAS LLC | Produced Fluid | 1,037.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW018 |
2010 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 6,666.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0008451 |
2011 | EXCO RESOURCES PA LLC | Produced Fluid | 43.40 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2012 | EXCO RESOURCES PA LLC | Produced Fluid | 1,086.16 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2012 | EXCO RESOURCES PA LLC | Produced Fluid | 1,043.46 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2012 | EXCO RESOURCES PA LLC | Produced Fluid | 8,305.06 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | EXCO RESOURCES PA LLC | Produced Fluid | 288.09 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2013 | EXCO RESOURCES PA LLC | Produced Fluid | 2.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC009 |
2013 | EXCO RESOURCES PA LLC | Produced Fluid | 4,372.52 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2013 | EXCO RESOURCES PA LLC | Produced Fluid | 438.56 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 15.50 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC024 |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 27.40 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 23.80 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 1,338.70 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | EXCO RESOURCES PA LLC | Produced Fluid | 1,665.20 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2015 | EXCO RESOURCES PA LLC | Produced Fluid | 109.80 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2015 | EXCO RESOURCES PA LLC | Produced Fluid | 1,265.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC009 |
2015 | EXCO RESOURCES PA LLC | Produced Fluid | 6,084.20 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | EXCO RESOURCES PA LLC | Produced Fluid | 147.40 Bbl | INJECTION DISPOSAL WELL | PAS2D205BCLE |
2019 | EXCO RESOURCES PA LLC | Produced Fluid | 6,764.50 Bbl | REUSE (AT WELL PAD) |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1891006 | Primary Facility | 2010-05-20 | Drilling/Alteration | Viol(s) Noted & Immediately Corrected | well id sign ordered will put up as soon as it gets in |
1929616 | Primary Facility | 2010-11-15 | Follow-up Inspection | No Violations Noted | |
1941448 | Primary Facility | 2011-01-05 | Routine/Complete Inspection | No Violations Noted | |
1961807 | Primary Facility | 2011-03-30 | Routine/Partial Inspection | No Violations Noted | |
1965851 | Primary Facility | 2011-04-14 | Routine/Complete Inspection | No Violations Noted | |
1966508 | Primary Facility | 2011-04-18 | Routine/Complete Inspection | No Violations Noted | |
2060363 | Primary Facility | 2012-04-17 | Routine/Complete Inspection | No Violations Noted | |
2062945 | Primary Facility | 2012-04-25 | Routine/Complete Inspection | No Violations Noted | |
2092502 | Primary Facility | 2012-08-15 | Routine/Complete Inspection | No Violations Noted | |
2116533 | Primary Facility | 2012-11-15 | Incident- Response to Accident or Event | Violation(s) Noted | Penn Twp. |
2120895 | Primary Facility | 2012-12-04 | Compliance Evaluation | Outstanding Violations - No Viols Req'd | |
2437797 | Primary Facility | 2015-12-30 | Routine/Complete Inspection | No Violations Noted | Arrived @ 12:53. Weather: foggy, cloudy, some fine drizzle. Four wells, formerly in production, were shut-in. Lease tender Bobby Hamel was onsite pumping rain water out of the containment around the produced water tank. All well cellars were filled with gravel. There were two open annular vents at each well. The 13-3/8” x 9-5/8” was vented with a 1” pipe. The 9-5/8” x 5-1/2” annulus was vented with a 2” pipe. The annuli were monitored with an Altair 5X gas meter calibrated on 12/28/15. |
2543927 | Primary Facility | 2016-12-08 | Routine/Complete Inspection | No Violations Noted | Routine Inspection; 12/8/2016. I entered the location at 09:57 and began the inspection. At the time of the inspection, the Patterson Unit 1H (081-20240), 2H (081-20241), 4H (081-20243), and 5H (081-20244) wells were in production. The well pad area was well vegetated and can be considered permanently stabilized. The well site has not been restored and the Well Site Compliance Information Request reply (submitted 9/21/2015) says the well site has been restored and the Notice of Termination was to be submitted in September of 2015. The well pad remains at its original size and the site currently does not conform to the permitted restoration plan. The original ESCGP has been expired since 11/23/2014.
The Department considers a well site to be restored under Section 3216(c) of the 2012 Oil and Gas Act when the oil or gas owners or operators meet the following: 1. All permanent post construction stormwater control features as identified in the Post Construction Stormwater Management/Site Restoration Pla |
2584380 | Primary Facility | 2017-03-28 | Routine/Complete Inspection | No Violations Noted | Arrived @ 10:00. Weather: cloudy, warm, light rain. There are 4 wells capable of production on location. At the time of my inspection the 1H and 2H were in production, 4H and 5H were locked and shut-in. There were 3 annular vent pipes at each well. All well cellars were filled with gravel. The annuli for the 2H were configured differently, but for the other wells, the 20” x 13-3/8” and 13-3/8” x 9-5/8” were open and the 9-5/8” x 5-1/2” was plumbed to a dump line. The annuli were monitored with an Altair 5X gas meter calibrated on 03/28/17. No combustible gas was detected at the annuli of the: 1H, 4H, and 5H. The annuli for the 2H were linked together and it was not possible at the time of my inspection to test for gas. |
2694390 | Primary Facility | 2018-02-14 | Routine/Complete Inspection | No Violations Noted | Weather was 30° and cloudy at time of inspection. Met with lease operator Bobby Hamel on location at time of inspection. Well had an analog pressure gauge attached above the swab valve. Pressure was approximately 320 psi at time of inspection. There were three annulus vents plumbed to surface. The 5 1/2 x 9 5/8 annulus vent was plumbed across location to the produced water tanks. The 9 5/8 x 13 3/8 and 13 3/8 x 20 annulus vents were open and 0% combustible gas was detected at time of inspection. No violations were noted at time of inspection. |
2832715 | Primary Facility | 2019-01-28 | Routine/Complete Inspection | No Violations Noted | On January 28, 2019, Department representative Brad Kline conducted a routine site inspection at EXCO Resources, LLC. Patterson Unit 1 pad. Site inspection log was onsite for review. No E&S issues were observed during the time of inspection. The site is stable and well vegetated meeting the 70% uniform, perennial, vegetative cover.
There are a total of 4 producing wells located on this well pad. All wells are tagged with API/well permit numbers. Well cellars are filled in with gravel. There are 4 GPU’s and 2 steel vertical production fluids tanks onsite. Production fluid tanks and GPUs were stationed in separate secondary containment. No violations noted. The Department recommends submitting a Notice of Termination and a Post-Drilling Well Site Restoration Report when the criteria are met and weather conditions permit. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1891006 | 589351 | 05/20/2010 | 2010-05-20 | 201G - Failure to post permit number, operator name, address, telephone number in a conspicuous manner at the site during drilling | Administrative | |
2116533 | 653903 | 11/15/2012 | 2012-11-15 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | Flowback and diesel fuel spill to south ditch of Patterson well pad. - Analyticals recd 4/25/2013, review by OG program 6/5/2013 |
2116533 | 653904 | 11/15/2012 | 2012-11-15 | 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | Environmental Health & Safety | Flowback and diesel fuel spill to south ditch of Patterson well pad. - Analyticals recd 4/25/2013, review by OG program 6/5/2013 |
2116533 | 653905 | 11/15/2012 | 2012-11-15 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety | Flowback and diesel fuel spill to south ditch of Patterson well pad. - Analyticals recd 4/25/2013, review by OG program 6/5/2013 |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
653903 | 290649 | NOV - Notice of Violation | Comply/Closed | 2013-06-05 | |||
653904 | 290649 | NOV - Notice of Violation | Comply/Closed | 2013-06-05 | |||
653905 | 290649 | NOV - Notice of Violation | Comply/Closed | 2013-06-05 |
For data sources see[7]