If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-081-20287 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.233928,"lon":-76.633736,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Lycoming | |
Municipality: Franklin Township | |
Operator Name: XTO ENERGY INC | |
Well Pad ID: 148304 | |
Farm/Lease Name: EVERBE FARMS 8518H | |
License Status: | |
Spud Date: | |
Permit Date: 2010-04-21 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.233928 | |
Longitude: -76.633736 |
Date | Event |
---|---|
2010-04-21 | New Permit Application |
2010-10-19 | Performed Spud Operation |
2010-11-27 | Drilling Completion |
2011-01-19 | Perforation |
2015-08-20 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2011-02-10 | 2011-02-10 | 4,907 | 5,479,698 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Scale Inhibitor - Greenhib 677 | Chemplex | Scale Inhibitor | |||||
Other (75) | 75.00 | 0.02 | ||||||
Salt of phosphonomethylated diamine | 25.00 | 0.00668000 | ||||||
Acid - 7.5 HCl Acid | Skylkine Chemical Corp. | Cleaning | Water | 7732-18-5 | 92.50 | 0.31 | ||
Whole Product | ||||||||
Hydrochloric acid | 7647-01-0 | 7.50 | 0.02 | |||||
Acid Iron Chelating Agt Ferriplex 40 | Chemplex | Acid Iron Chelating | Nitrilotriacetic acid trisodium monohydrate | 18662-53-8 | 40.00 | 0.00050000 | ||
Sodium sulfate | 7757-82-6 | 2.00 | 0.00002000 | |||||
Other -(non hazardous) | 57.00 | 0.00071000 | ||||||
Sodium hydroxide | 1310-73-2 | 1.00 | 0.00001000 | |||||
Water | Water | 7732-18-5 | 100.00 | 89.19 | ||||
Friction Reducer - Plexslick 921 | Chemplex | Friction Reducer | ||||||
Other (70) | 70.00 | 0.03 | ||||||
Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.01 | |||||
Biocide - Plexcide 24L | Chemplex | Biocide | Sodium hydroxide | 1310-73-2 | 4.00 | 0.00119000 | ||
Other (72) | 72.00 | 0.02 | ||||||
Tetrahydro-3,5-dimethyl,2H-1,3,5-thiadiazine-2-thione | 533-74-4 | 24.00 | 0.00715000 | |||||
Sand | Proppant | Quartz | 14808-60-7 | 100.00 | 10.35 | |||
Acid Non Emulsifier PlexBreak-145 | Chemplex | Acid Non-Emulsifier | Methanol | 67-56-1 | 15.00 | 0.00005000 | ||
Other -(non hazardous) | 85.00 | 0.00029000 | ||||||
Acid Corrosion Inhibitor Plexhib 256 | Chemplex | Acid Corrosion Inhibitor | ||||||
Methanol | 67-56-1 | 40.00 | 0.00013000 | |||||
Other -(non hazardous) | 52.00 | 0.00017000 | ||||||
Propargyl alcohol | 107-19-7 | 8.00 | 0.00003000 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | XTO ENERGY INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | XTO ENERGY INC | 776,567.00 | 301 | 0.00 | 0 | 0.00 | 0 |
2012 | XTO ENERGY INC | 522,009.00 | 357 | 0.00 | 0 | 0.00 | 0 |
2013 | XTO ENERGY INC | 364,191.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | XTO ENERGY INC | 299,331.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | XTO ENERGY INC | 215,109.00 | 345 | 0.00 | 0 | 0.00 | 0 |
2016 | XTO ENERGY INC | 210,751.00 | 347 | 0.00 | 0 | 0.00 | 0 |
2017 | XTO ENERGY INC | 177,166.00 | 354 | 0.00 | 0 | 0.00 | 0 |
2018 | XTO ENERGY INC | 196,480.24 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | XTO ENERGY INC | 168,966.99 | 364 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | XTO ENERGY INC | Produced Fluid | 910.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2011 | XTO ENERGY INC | Fracing Fluid Waste | 1,017.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0095273 |
2011 | XTO ENERGY INC | Produced Fluid | 3,467.00 Bbl | INJECTION DISPOSAL WELL | 34-133-24096 |
2011 | XTO ENERGY INC | Produced Fluid | 3,468.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NC001 |
2011 | XTO ENERGY INC | Produced Fluid | 115.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | EPA ID: 748-163 |
2011 | XTO ENERGY INC | Produced Fluid | 2,322.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2011 | XTO ENERGY INC | Produced Fluid | 100.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 34-133-24189 |
2011 | XTO ENERGY INC | Fracing Fluid Waste | 1,048.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2011 | XTO ENERGY INC | Produced Fluid | 150.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0254185 |
2011 | XTO ENERGY INC | Produced Fluid | 381.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0095273 |
2011 | XTO ENERGY INC | Produced Fluid | 3,631.00 Bbl | INJECTION DISPOSAL WELL | 34-133-21076 |
2012 | XTO ENERGY INC | Produced Fluid | 1,599.00 Bbl | INJECTION DISPOSAL WELL | 34-133-24096 |
2012 | XTO ENERGY INC | Produced Fluid | 742.00 Bbl | INJECTION DISPOSAL WELL | 34-133-24189 |
2012 | XTO ENERGY INC | Produced Fluid | 104.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2012 | XTO ENERGY INC | Produced Fluid | 4,442.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
2012 | XTO ENERGY INC | Produced Fluid | 108.00 Bbl | INJECTION DISPOSAL WELL | 114 |
2012 | XTO ENERGY INC | Produced Fluid | 525.00 Bbl | INJECTION DISPOSAL WELL | 34-133-20114 |
2012 | XTO ENERGY INC | Produced Fluid | 1,190.00 Bbl | INJECTION DISPOSAL WELL | 34-133-21076 |
2012 | XTO ENERGY INC | Produced Fluid | 108.00 Bbl | INJECTION DISPOSAL WELL | 0114 |
2013 | XTO ENERGY INC | Produced Fluid | 262.00 Bbl | INJECTION DISPOSAL WELL | 34-133-20114 |
2013 | XTO ENERGY INC | Produced Fluid | 738.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2013 | XTO ENERGY INC | Produced Fluid | 396.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2013 | XTO ENERGY INC | Produced Fluid | 316.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2013 | XTO ENERGY INC | Produced Fluid | 485.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
2013 | XTO ENERGY INC | Produced Fluid | 221.00 Bbl | INJECTION DISPOSAL WELL | 34-133-24096 |
2014 | XTO ENERGY INC | Produced Fluid | 104.00 Bbl | INJECTION DISPOSAL WELL | 34-133-20114 |
2014 | XTO ENERGY INC | Produced Fluid | 1,859.93 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2014 | XTO ENERGY INC | Produced Fluid | 25.00 Bbl | INJECTION DISPOSAL WELL | 34-133-24096 |
2014 | XTO ENERGY INC | Produced Fluid | 301.95 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2014 | XTO ENERGY INC | Produced Fluid | 724.58 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | XTO ENERGY INC | Produced Fluid | 774.00 Bbl | INJECTION DISPOSAL WELL | 34-133-24096 |
2015 | XTO ENERGY INC | Produced Fluid | 109.00 Bbl | INJECTION DISPOSAL WELL | 34-133-21076 |
2015 | XTO ENERGY INC | Produced Fluid | 1,139.31 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | XTO ENERGY INC | Produced Fluid | 1,123.47 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2016 | XTO ENERGY INC | Other Oil & Gas Wastes | 3.16 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2016 | XTO ENERGY INC | Produced Fluid | 1,201.85 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2016 | XTO ENERGY INC | Produced Fluid | 458.64 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2016 | XTO ENERGY INC | Produced Fluid | 616.58 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2016 | XTO ENERGY INC | Produced Fluid | 103.00 Bbl | INJECTION DISPOSAL WELL | 34-133-21076 |
2016 | XTO ENERGY INC | Produced Fluid | 256.19 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2016 | XTO ENERGY INC | Produced Fluid | 764.00 Bbl | INJECTION DISPOSAL WELL | 34-133-24096 |
2017 | XTO ENERGY INC | Produced Fluid | 114.00 Bbl | INJECTION DISPOSAL WELL | 34-133-24189 |
2017 | XTO ENERGY INC | Produced Fluid | 2,573.70 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017 | XTO ENERGY INC | Produced Fluid | 104.00 Bbl | INJECTION DISPOSAL WELL | 34-133-24096 |
2017 | XTO ENERGY INC | Produced Fluid | 431.76 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2017 | XTO ENERGY INC | Produced Fluid | 215.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2018 | XTO ENERGY INC | Produced Fluid | 652.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | XTO ENERGY INC | Produced Fluid | 656.38 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018 | XTO ENERGY INC | Produced Fluid | 520.03 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018 | XTO ENERGY INC | Produced Fluid | 108.00 Bbl | INJECTION DISPOSAL WELL | 34-133-24189 |
2019 | XTO ENERGY INC | Produced Fluid | 683.50 Bbl | INJECTION DISPOSAL WELL | 34-133-21076 |
2019 | XTO ENERGY INC | Produced Fluid | 568.00 Bbl | INJECTION DISPOSAL WELL | 34-133-24189 |
2019 | XTO ENERGY INC | Produced Fluid | 456.00 Bbl | INJECTION DISPOSAL WELL | 34-133-24096 |
2019 | XTO ENERGY INC | Produced Fluid | 299.00 Bbl | REUSE (AT WELL PAD) | |
2019 | XTO ENERGY INC | Produced Fluid | 111.00 Bbl | INJECTION DISPOSAL WELL | 34-133-20114 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1929241 | Primary Facility | 2010-11-22 | Drilling/Alteration | No Violations Noted | |
1942533 | Primary Facility | 2011-01-05 | Routine/Partial Inspection | Violation(s) Noted | |
1942534 | Primary Facility | 2011-01-06 | Follow-up Inspection | Violation(s) & Outstanding Violations | |
1946127 | Primary Facility | 2011-01-20 | Routine/Partial Inspection | Violation(s) Noted | |
1946141 | Primary Facility | 2011-01-25 | Routine/Partial Inspection | Outstanding Violations - No Viols Req'd | |
1947228 | Primary Facility | 2011-01-28 | Routine/Complete Inspection | No Violations Noted | |
1950446 | Primary Facility | 2011-02-16 | Routine/Partial Inspection | Violation(s) Noted | |
1960306 | Primary Facility | 2011-03-25 | Follow-up Inspection | No Violations Noted | |
1974204 | Primary Facility | 2011-05-17 | Follow-up Inspection | No Violations Noted | |
1974925 | Primary Facility | 2011-05-20 | Routine/Complete Inspection | No Violations Noted | |
1987477 | Primary Facility | 2011-07-11 | Follow-up Inspection | Violation(s) Noted | |
2012746 | Primary Facility | 2011-10-19 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | |
2074214 | Primary Facility | 2012-06-06 | Routine/Complete Inspection | No Violations Noted | |
2106600 | Primary Facility | 2012-10-05 | Routine/Complete Inspection | No Violations Noted | |
2161173 | Primary Facility | 2013-04-24 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | |
2287499 | Primary Facility | 2014-07-14 | Routine/Complete Inspection | No Violations Noted | NOT inspection. site not restored, erosion channels noted on two separate locations going outside the LOD. Violations noted to the ESCGP |
2410502 | Primary Facility | 2015-09-21 | Routine/Complete Inspection | No Violations Noted | This inspection is in response to XTO's recent notification that violations cited on 7/14/2014 have been corrected. The PCSM plans incorporated into a major modification approved 4/13/2015 have been implemented. Vegetation has been established but has not yet reached 70% uniform perennial cover. Some slight erosion was noted exiting the same rock-lined ditch noted on 7/14/2015 but that area is now contained within the infiltration basin. Violations cited on 7/14/2015 are considered closed. In addition, The well site has not been restored. No Violations Noted. |
2433655 | Primary Facility | 2015-12-14 | Routine/Complete Inspection | No Violations Noted | Arrived at 14:15, weather hot and cloudy. There were two wells TD’d on this location. |
2514927 | Primary Facility | 2016-08-24 | Site Restoration | No Violations Noted | Notice of Termination/Well Site Restoration Report Inspection; 8/24/2016.
I entered the site at 15:05 to find two wells in production. The stormwater BMP’s identified in the PCSM (Post Construction Stormwater Management) plan have been implemented and the well site is permanently stabilized. The well site has not been re-graded and restored as the restoration plan indicates. This concept is further reiterated by your submission of the 2-year extension request (approved on 10/29/2015) which provides additional time to restore the site if stormwater is handled for the entire remaining site. I recommend approving the Notice of Termination at this time and denying the Well Site Restoration Report. I encourage you to submit the Well Site Restoration Report when the well site is restored so that permanent stabilization is established by the end of the extension period. No Violations Noted. |
2528550 | Primary Facility | 2016-10-13 | Site Restoration | No Violations Noted | Well Site Restoration Report Inspection; 10/13/2016.
I entered the site at 12:51 to find two wells (081-20287 and 081-20414) in production. The stormwater BMP’s identified in the PCSM (Post Construction Stormwater Management) plan have been implemented and the well site is permanently stabilized. A 2-year restoration extension was issued on 10/29/2015. In the last inspection on 8/24/2016, the ESCGP was terminated. Since the last inspection, the ESCGP was modified so that the entire well pad surface can be retained while the well is in production. The operator provided justification that the pad surface is required to accommodate the production/maintenance of the wells and for work-over rig access. I recommend the Well Site Restoration Report be approved. No Violations Noted |
2773934 | Primary Facility | 2018-09-12 | Routine/Complete Inspection | No Violations Noted | Two wells staged for production phase. Two each sand and water separators. No leaks detected from production equipment. No violations noted. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1942533 | 602916 | 01/05/2011 | 2011-01-05 | 307CSL - Discharge of industrial waste to waters of Commonwealth without a permit. | Environmental Health & Safety | Drill mud / cuttings on pad |
1942533 | 602917 | 01/05/2011 | 2011-01-05 | CSL402POTPOL - There is a potential for polluting substance(s) reaching Waters of the Commonwealth and may require a permit | Environmental Health & Safety | |
1942533 | 602918 | 01/05/2011 | 2011-01-05 | 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. | Administrative | 78.56(a) Drill mud / cuttings on ground. Not contained |
1942533 | 602919 | 01/05/2011 | 2011-01-05 | 91.33POLLINC - Pollution incident was not reported to DEP. | Environmental Health & Safety | |
1942534 | 602920 | 01/06/2011 | 2011-01-06 | 307CSL - Discharge of industrial waste to waters of Commonwealth without a permit. | Environmental Health & Safety | Drill mud / cuttings on pad |
1942534 | 602921 | 01/06/2011 | 2011-01-06 | CSL402POTPOL - There is a potential for polluting substance(s) reaching Waters of the Commonwealth and may require a permit | Environmental Health & Safety | |
1942534 | 602922 | 01/06/2011 | 2011-01-06 | 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. | Administrative | 78.56(a) Drill mud / cuttings on ground. Not contained |
1946127 | 603757 | 01/20/2011 | 2011-01-20 | 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. | Administrative | 78.56(a) Failure to contain pollutional substance |
1946127 | 603758 | 01/20/2011 | 2011-01-20 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | |
1946127 | 603759 | 01/20/2011 | 2011-01-20 | CSL402POTPOL - There is a potential for polluting substance(s) reaching Waters of the Commonwealth and may require a permit | Environmental Health & Safety | |
1950446 | 604980 | 02/16/2011 | 2011-02-16 | 402POTNLPOLL - There is a potential for polluting substance(s) reaching Waters of the Commonwealth and may require a permit. | Environmental Health & Safety | |
1950446 | 604981 | 02/16/2011 | 2011-02-16 | 91.33POLLINC - Pollution incident was not reported to DEP. | Environmental Health & Safety | |
1950446 | 604982 | 02/16/2011 | 2011-02-16 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | |
1987477 | 615226 | 07/11/2011 | 2011-07-11 | 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days | Administrative | Defective Cement: Gas found in the annular space of the 9 5/8 x 5 1/2 casing. |
For data sources see[8]