If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-081-20298 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.237861,"lon":-76.600611,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Lycoming | |
Municipality: Franklin Township | |
Operator Name: EXCO RESOURCES PA LLC | |
Well Pad ID: 150883 | |
Farm/Lease Name: WARNER UNIT 1H | |
License Status: | |
Spud Date: | |
Permit Date: 2010-05-25 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.237861 | |
Longitude: -76.600611 |
Date | Event |
---|---|
2010-05-25 | New Permit Application |
2010-06-06 | Performed Spud Operation |
2010-06-26 | Drilling Completion |
2010-07-30 | Perforation |
2010-08-26 | DEVIATED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | CHIEF OIL & GAS LLC | 4,873.00 | 11 | 0.00 | 0 | 0.00 | 0 |
2011 | EXCO RESOURCES PA LLC | 25,334.00 | 122 | 0.00 | 0 | 0.00 | 0 |
2012 | EXCO RESOURCES PA LLC | 22,413.39 | 122 | 0.00 | 0 | 0.00 | 0 |
2013 | EXCO RESOURCES PA LLC | 40,232.00 | 290 | 0.00 | 0 | 0.00 | 0 |
2014 | EXCO RESOURCES PA LLC | 28,887.00 | 364 | 0.00 | 0 | 0.00 | 0 |
2015 | EXCO RESOURCES PA LLC | 17,104.00 | 300 | 0.00 | 0 | 0.00 | 0 |
2016 | EXCO RESOURCES PA LLC | 16,167.00 | 279 | 0.00 | 0 | 0.00 | 0 |
2017 | EXCO RESOURCES PA LLC | 13,623.00 | 337 | 0.00 | 0 | 0.00 | 0 |
2018 | EXCO RESOURCES PA LLC | 10,220.00 | 364 | 0.00 | 0 | 0.00 | 0 |
2019 | EXCO RESOURCES PA LLC | 6,933.00 | 363 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2010 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 1,165.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2010 | CHIEF OIL & GAS LLC | Produced Fluid | 119.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0008451 |
2011 | EXCO RESOURCES PA LLC | Drilling Fluid Waste | 3,201.90 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2011 | EXCO RESOURCES PA LLC | Drilling Fluid Waste | 1,205.25 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | EPA ID: 748-163 |
2013 | EXCO RESOURCES PA LLC | Fracing Fluid Waste | 51.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | EXCO RESOURCES PA LLC | Fracturing Fluid Waste | 43.68 Tons | LANDFILL | 301358 |
2019 | EXCO RESOURCES PA LLC | Produced Fluid | 20.00 Bbl | REUSE (AT WELL PAD) |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1887284 | Primary Facility | 2010-05-26 | Routine/Complete Inspection | Violation(s) Noted | |
1890982 | Primary Facility | 2010-06-10 | Drilling/Alteration | No Violations Noted | Union drilling rig# 58 drilling on location @ 2469 ft deep all ok. location clean and dry. CASING PROGRAM****** 16" casing ran to 100 ft cemented to surface// 13 3/8 casing ran to 393 ft deep cemented to surface with 10bbl return to surface/// 9 5/8 casing ran to 1397 ft deep cemented to surface with 18 bbl return to surface.. B.O.P TEST!!! bop tested 06/08/10 3rd party test of bop all test good and held to 2500 lbs |
1911603 | Primary Facility | 2010-09-08 | Routine/Partial Inspection | No Violations Noted | |
1985090 | Primary Facility | 2011-06-27 | Routine/Partial Inspection | Violation(s) Noted | |
2032194 | Primary Facility | 2011-12-22 | Routine/Partial Inspection | Viol(s) Noted & Immediately Corrected | |
2072052 | Primary Facility | 2012-05-31 | Routine/Complete Inspection | No Violations Noted | |
2077069 | Primary Facility | 2012-06-12 | Routine/Complete Inspection | No Violations Noted | |
2081348 | Primary Facility | 2012-07-02 | Routine/Complete Inspection | No Violations Noted | |
2091240 | Primary Facility | 2012-08-13 | Drilling/Alteration | No Violations Noted | |
2098756 | Primary Facility | 2012-09-11 | Routine/Partial Inspection | No Violations Noted | |
2123241 | Primary Facility | 2012-12-06 | Routine/Complete Inspection | No Violations Noted | |
2130024 | Primary Facility | 2013-01-10 | Routine/Complete Inspection | Violation(s) Noted | A puddle of unknown substance was found outside of containment. Collected sample 0943064 from puddle. Results of sample show a pollutional substance. |
2132663 | Primary Facility | 2013-01-16 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | Inspection results changed from pending to outstanding violations, no new violations on 2/7/2013 based on results of sample 0943064. |
2136665 | Primary Facility | 2013-01-24 | Incident- Response to Accident or Event | Outstanding Violations - No Viols Req'd | |
2152181 | Primary Facility | 2013-03-29 | Routine/Complete Inspection | No Violations Noted | |
2177917 | Primary Facility | 2013-06-25 | Routine/Complete Inspection | No Violations Noted | |
2184119 | Primary Facility | 2013-07-16 | Routine/Complete Inspection | No Violations Noted | |
2200827 | Primary Facility | 2013-08-13 | Routine/Partial Inspection | Viol(s) Noted & Immediately Corrected | diesel spill to pad. excavated and field corfirmed w/ PID |
2435525 | Primary Facility | 2015-12-04 | Routine/Complete Inspection | No Violations Noted | I arrived onsite at 09:51. Five of the six wells on the pad were in production. The tank pad (located to the southwest of the well pad) remains in place yet no work has been done on any of the wells since July 2013. According to the well records, drilling on the last well (081-20492) was completed on 12/7/2011 and there are no other active well permits for this well site. Section 3216 (c) requires that "within nine months after completion of drilling of a well, the owner or operator shall restore the well site." The Well Site Restoration assessment summary indicates that a new well permit was to be submitted to the Department Fall 2015. As of the date of this inspection report, no well permit applications are pending or have been issued according to eFacts. In order to bring the well site into compliance, the Department recommends that EXCO restore the well site in accordance with Section 3216(c) or comply with the restoration schedule as submitted. |
2492477 | Primary Facility | 2016-06-09 | Routine/Complete Inspection | No Violations Noted | Arrived @ 09:00. Weather sunny and warm. No company representatives were present at the time of the inspection. At the time of my inspection, two of the six wells on site (4H and 5H) were in production.
Warner Unit 1H: Gravel cellar. Top gauge: 204 psi (digital), 5-1/2” gauge: 400 psi (digital). Annular vents (13-3/8” x 9-5/8” and 9-5/8” x 5-1/2”) were monitored for methane with an Altair 5X gas multimeter (calibrated on 5/23/16). No gas was detected. No violations were observed at the time of this inspection. Left at 09:30. |
2568239 | Primary Facility | 2017-03-06 | Routine/Complete Inspection | No Violations Noted | Routine Inspection; 3/6/2017.Dan Harvey (DEP) and I arrived onsite at 09:00 and met with the landowner. Five of the six wells on the pad were in production. The tank pad has been removed and the site has been restored in accordance with the ESCGP which was upgraded to include Post Construction Stormwater Management (PCSM). The site is well vegetated but has not quite reached >70% uniform perennial vegetative growth.
We discussed the PCSM features and maximizing the amount of area that can be restored to crop production. A long rock pile and a steep water bar at the northwest corner (near the entrance off SR118) of the well pad have not been restored back to approximate original contours. I recommend moving the rock pile onto the well pad and smoothing the water bar/soil stockpile so that the area can return to agricultural production. The landowner and the operator have already coordinated on the removal of silt sock on the site so that the fields can be returned to agricultural production. No Violation |
2816683 | Primary Facility | 2018-12-18 | Routine/Complete Inspection | No Violations Noted | Three wells stage for production. Three GPUs not within containment. No leaks detected from production equipment. No violations noted. |
2817240 | Primary Facility | 2018-12-18 | Routine/Complete Inspection | No Violations Noted | Five wells staged for production. One well in regulatory inactive status. Six GPUs not within containment. No leaks detected from production equipment. No violations noted. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1887284 | 588054 | 05/26/2010 | 2010-05-26 | 201G - Failure to post permit number, operator name, address, telephone number in a conspicuous manner at the site during drilling | Administrative | |
1985090 | 614690 | 06/27/2011 | 2011-06-27 | 201G - Failure to post permit number, operator name, address, telephone number in a conspicuous manner at the site during drilling | Administrative | |
2032194 | 628557 | 12/22/2011 | 2011-12-22 | 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | Environmental Health & Safety | While site being cleaned after rig move, found oily water off containment on SW portion. Immediately vacced up. |
2130024 | 659929 | 01/10/2013 | 2013-01-10 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | |
2130024 | 659930 | 01/10/2013 | 2013-01-10 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety | |
2130024 | 659931 | 01/10/2013 | 2013-01-10 | 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | Environmental Health & Safety | |
2130024 | 659932 | 01/10/2013 | 2013-01-10 | 91.33A - Failure to notify DEP of pollution incident. No phone call made forthwith | Administrative | |
2200827 | 676592 | 08/13/2013 | 2013-08-13 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety | |
2200827 | 676593 | 08/13/2013 | 2013-08-13 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
659929 | 293709 | NOV - Notice of Violation | Comply/Closed | 2014-11-12 | |||
659930 | 293709 | NOV - Notice of Violation | Comply/Closed | 2014-11-12 | |||
659931 | 293709 | NOV - Notice of Violation | Comply/Closed | 2014-11-12 | |||
659932 | 293709 | NOV - Notice of Violation | Comply/Closed | 2014-11-12 |