If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-081-20345 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.276231,"lon":-77.286936,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Lycoming | |
Municipality: Watson Township | |
Operator Name: ARD OPR LLC | |
Well Pad ID: 149198 | |
Farm/Lease Name: ROBERT C ULMER A1H | |
License Status: | |
Spud Date: | |
Permit Date: 2010-08-31 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.276231 | |
Longitude: -77.286936 |
Date | Event |
---|---|
2010-08-31 | New Permit Application |
2011-03-17 | Performed Spud Operation |
2011-05-17 | New Permit Application |
2011-07-01 | Drilling Completion |
2011-11-12 | Perforation |
2012-04-26 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2011-11-28 | 2011-11-28 | 7,979 | 4,617,958 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Water | Anadarko | Carrier/Base Fluid | Water | 7732-18-5 | 100.00 | 84.24 | |
GBO-1 | Trican Well Service | Gel Breaker | Sodium perborate tetrahydrate | 10486-00-7 | 100.00 | 0.00025000 | ||
TXP-8 | Trican Well Service | Friction Reducer | ||||||
Acid, Hydrochloric (7.5) | Trican Well Service | Solvent | Hydrochloric acid | 7647-01-0 | 7.50 | 0.03 | ||
WG-111L | Trican Well Service | Viscosifier/Gelant | Polysaccharide blend | 60.00 | 0.00363000 | |||
Distillates, petroleum, hydrotreated light | 64742-47-8 | 60.00 | 0.00363000 | |||||
TXP-10 | Trican Well Service | Scale Inhibitor | Acrylate phosphonate copolymer | 40.00 | 0.00575000 | |||
Water | 7732-18-5 | 70.00 | 0.01 | |||||
Neutralized organic acid | 20.00 | 0.00287000 | ||||||
1,2-Propylene glycol | 57-55-6 | 10.00 | 0.00144000 | |||||
TXP-8 | Friction Reducer | |||||||
Cationic water-soluble polymer emulsion | 100.00 | 0.11 | ||||||
BioClear 5000 | Trican Well Service | Biocide | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 10.00 | 0.00253000 | ||
Polyethylene glycol | 25322-68-3 | 70.00 | 0.01 | |||||
TXP-11 | Trican Well Service | Clay Control | Chloride | 16887-00-6 | 30.00 | 0.04 | ||
Water | 7732-18-5 | 60.00 | 0.08 | |||||
Inorganic Chemical | 20.00 | 0.02 | ||||||
Poly Electrolyte | 40.00 | 0.05 | ||||||
Sand (Proppant) | Trican Well Service | Proppant | Quartz | 14808-60-7 | 100.00 | 14.92 | ||
FEAC-20 | Trican Well Service | Iron Control | Citric acid | 77-92-9 | 30.00 | 0.00141000 | ||
Acetic acid | 64-19-7 | 50.00 | 0.00236000 | |||||
AI-7NR | Trican Well Service | Corrosion Inhibitor | Propargyl alcohol | 107-19-7 | 1.00 | 0.00002000 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | ANADARKO E&P ONSHORE LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | ANADARKO E&P ONSHORE LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | ANADARKO E&P ONSHORE LLC | 1,581,253.00 | 337 | 0.00 | 0 | 0.00 | 0 |
2013 | ANADARKO E&P ONSHORE LLC | 878,093.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | ANADARKO E&P ONSHORE LLC | 661,902.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | ANADARKO E&P ONSHORE LLC | 382,816.00 | 247 | 0.00 | 0 | 0.00 | 0 |
2016 | ANADARKO E&P ONSHORE LLC | 546,840.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2017 | ARD OPR LLC | 350,350.61 | 364 | 0.00 | 0 | 0.00 | 0 |
2018 | ARD OPR LLC | 291,322.89 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | ARD OPR LLC | 245,425.09 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | ANADARKO E&P ONSHORE LLC | Drill Cuttings | 228.57 Tons | LANDFILL | THR029 |
2011 | ANADARKO E&P ONSHORE LLC | Drill Cuttings | 82.97 Tons | LANDFILL | 06-08438 |
2011 | ANADARKO E&P ONSHORE LLC | Drill Cuttings | 864.21 Tons | OTHER | |
2011 | ANADARKO E&P ONSHORE LLC | Drill Cuttings | 12.24 Tons | LANDFILL | 100955 |
2012 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 2,529.28 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | ANADARKO E&P ONSHORE LLC | Drilling Fluid Waste | 110.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
2013 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 2,426.52 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 1,191.38 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 116.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 1,034.78 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 77.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
2016 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 206.80 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2016 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 149.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2016 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 191.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW005 |
2017 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 77.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
2017 | ARD OPR LLC | Produced Fluid | 51.13 Bbl | REUSE (AT WELL PAD) | |
2017 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 178.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 67.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2018 | ARD OPR LLC | Produced Fluid | 155.34 Bbl | REUSE (AT WELL PAD) | |
2019 | ARD OPR LLC | Produced Fluid | 130.91 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1974185 | Primary Facility | 2011-05-16 | Follow-up Inspection | No Violations Noted | |
1983978 | Primary Facility | 2011-06-28 | Drilling/Alteration | No Violations Noted | |
1988564 | Primary Facility | 2011-07-19 | Routine/Partial Inspection | No Violations Noted | |
2005982 | Primary Facility | 2011-09-23 | Drilling/Alteration | No Violations Noted | |
2452448 | Primary Facility | 2016-02-23 | Routine/Complete Inspection | No Violations Noted | |
2622036 | Primary Facility | 2017-07-20 | Routine/Complete Inspection | No Violations Noted | Routine inspection of unconventional wll in production. No violations noted at time of inspection. |
2700885 | Primary Facility | 2018-02-13 | Routine/Complete Inspection | No Violations Noted | Routine inspection; 2/13/2018.
Three wells were in production at the time of the inspection. The ESCGP used for construction has expired. The restoration schedule provided to the Department indicated the site would be re-permitted to include PCSM in 2017. I recommend re-permitting the site and installing PCSM. No violations noted. |
2789284 | Primary Facility | 2018-10-16 | Routine/Complete Inspection | No Violations Noted | Three wells stage for production. Three water separators. No leaks detected from production equipment. No violations noted. |
For data sources see[8]