If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
| Well ID: 37-081-20376 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.425036,"lon":-76.907792,"icon":""}]} |
| Country: United States | |
| State: Pennsylvania | |
| County: Lycoming | |
| Municipality: Cascade Township | |
| Operator Name: ARD OPR LLC | |
| Well Pad ID: 145402 | |
| Farm/Lease Name: CHARLES J MCNAMEE | |
| License Status: INACTIVE | |
| Spud Date: 2010-11-02 | |
| Permit Date: 2010-10-15 | |
| Well Type: GAS | |
| Unconventional Well: Y | |
| Configuration: Horizontal Well | |
| Conservation: No | |
| Latitude: 41.425036 | |
| Longitude: -76.907792 |
| Date | Event |
|---|---|
| 2010-10-15 | New Permit Application |
| 2010-11-01 | Performed Spud Operation |
| 2010-12-17 | Drilling Completion |
| 2013-04-06 | Perforation |
| 2014-03-14 | DEVIATED |
| 2019-10-01 | Inactive Well Request Granted |
For data sources see[4]
| Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
|---|---|---|---|---|---|
| 1 | 2013-04-24 | 2013-04-24 | 7,181 | 925,606 |
| Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
|---|---|---|---|---|---|---|---|---|
| 1 | BXL A | Trican Well Service | Gel Breaker | Proprietary | Proprietary | 70.0 | None | |
| Bio Clear 1000 | Trican Well Service | Biocide | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 100.0 | 0.00047 | ||
| Bio-Clear 5000 | Polyethylene glycol | 25322-68-3 | 70.0 | 0.03341 | ||||
| 2,2-dibromo-3-nitrilopropionamide | 10222-01-2 | 10.0 | 0.00477 | |||||
| Acid, Hydrochloric (3.5) | Trican Well Service | General Acidizing | ||||||
| Acid, Hydrochloric (3.5) | Water | 7732-18-5 | 85.0 | None | ||||
| Hydrochloric Acid | 7647-01-0 | 15.0 | None | |||||
| TXP-11 | Water | 7732-18-5 | 60.0 | None | ||||
| Poly electrolyte | NA | 40.0 | None | |||||
| Inorganic chemical | NA | 20.0 | None | |||||
| Various chlorides | 16887-00-6 | 30.0 | None | |||||
| FR-15 | Paraffinic, Naphthenic Solvent | 64742-47-8 | 25.0 | 0.01314 | ||||
| Proprietary Amide | Proprietary | 2.5 | 0.00131 | |||||
| Sand (Proppant) (lbs) | Trican Well Service | Proppant | ||||||
| TXP-8 | Trican Well Service | Friction Reducer | Cationic water-soluble polymer emulsion | Proprietary | 100.0 | None | ||
| WBO-2 | Trican Well Service | Gel Breaker | Sodium persulfate | 7775-27-1 | 100.0 | None | ||
| Bio-Clear 5000 | Trican Well Service | Biocide | ||||||
| FEAC-20 | ||||||||
| DF-1 | Trican Well Service | De-foaming Agent | Non-hazardous materials only in the product | NA | 100.0 | None | ||
| WG-111L | Trican Well Service | Viscosifier; Gelant | Light hydrotreated petroleum distillate | 64742-47-8 | 60.0 | None | ||
| Polysaccharide blend | NA | 60.0 | None | |||||
| Water | Anadarko | Carrier / Base Fluid | 7732-18-5 | 100.0 | 84.05925 | |||
| WXB-10 | Trican Well Service | Fracturing cross linker | Borate salts | 1319-33-1 | 60.0 | None | ||
| Light hydrotreated petroleum distillate | 64742-47-8 | 60.0 | None | |||||
| FR-15 | Trican Well Service | Friction Reducer | ||||||
| CS-1 | Trican Well Service | Clay Stabilizer | Surfactant | Proprietary | 5.0 | None | ||
| Propylene glycol | 57-55-6 | 20.0 | None | |||||
| Blend | Proprietary | 25.0 | None | |||||
| Inorganic salts | Proprietary | 30.0 | None | |||||
| WBE-6 | Trican Well Service | Gel Breaker | No hazardous ingredients | NA | 100.0 | None | ||
| TXP-11 | Trican Well Service | Clay Stabilizer | ||||||
| TXP-10 | Trican Well Service | Scale Inhibitor | Acrylate phosphonate copolymer | Proprietary | 40.0 | None | ||
| Neutralized organic acid | Proprietary | 20.0 | None | |||||
| Water | 7732-18-5 | 70.0 | None | |||||
| Propylene glycol | 57-55-6 | 10.0 | None | |||||
| FEAC-20 | Trican Well Service | Iron Control | Citric Acid | 77-92-9 | 30.0 | 0.00206 | ||
| Acetic Acid | 64-19-7 | 50.0 | 0.00343 | |||||
| FR-14 | Inorganic salt | Proprietary | 30.0 | None | ||||
| Acetic Acid | 64-19-7 | 5.0 | None | |||||
| GBO-1 | Trican Well Service | Gel Breaker | Sodium perborate tetrahydrate | 10486-00-7 | 100.0 | None | ||
| TXP-10 | ||||||||
| Acid, Hydrochloric (7.5) | Trican Well Service | General Acidizing | Hydrochloric Acid | 7647-01-0 | 7.5 | None | ||
| AI-7NR | Trican Well Service | Corrosion Inhibitor | Prop-2-yn-1-ol | 107-19-7 | 1.0 | 0.00003000 | ||
| WG-111L | ||||||||
| Acid, Hydrochloric (7.5) | Water | 7732-18-5 | 92.5 | None | ||||
| WXB-10 | ||||||||
| CS-1 | ||||||||
| FR-14 | Trican Well Service | Friction Reducer | ||||||
| Sand (Proppant) (lbs) | Quartz | 14808-60-7 | 70.0 | 11.08116 | ||||
| Hexamethylenetretramine | 100-97-0 | 1.0 | 0.1583 | |||||
| WG-111D | Trican Well Service | Water gellant | Guar gum | 9000-30-0 | 100.0 | None |
For data sources see[5]
| Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
|---|---|---|---|---|---|---|---|
| 2010 | ANADARKO E&P ONSHORE LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
| 2011 | ANADARKO E&P ONSHORE LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
| 2012 | ANADARKO E&P ONSHORE LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
| 2013 | ANADARKO E&P ONSHORE LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
| 2014 | ANADARKO E&P ONSHORE LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
| 2015 | ANADARKO E&P ONSHORE LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
| 2016 | ANADARKO E&P ONSHORE LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
| 2017 | ARD OPR LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
| 2019 | ARD OPR LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
| Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
|---|---|---|---|---|---|
| 2011 | ANADARKO E&P ONSHORE LLC | Drill Cuttings | 122.21 Tons | LANDFILL | 101397 |
For data sources see[7]
| Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|---|
| 1920643 | Primary Facility | 2010-10-04 | Routine/Partial Inspection | No Violations Noted | |
| 1928743 | Primary Facility | 2010-11-19 | Drilling/Alteration | No Violations Noted | |
| 1933410 | Primary Facility | 2010-10-07 | Drilling/Alteration | No Violations Noted | |
| 1938085 | Primary Facility | 2010-12-18 | Drilling/Alteration | No Violations Noted | |
| 1943068 | Primary Facility | 2011-01-14 | Routine/Partial Inspection | No Violations Noted | |
| 2018142 | Primary Facility | 2011-11-08 | Routine/Complete Inspection | No Violations Noted | |
| 2057302 | Primary Facility | 2012-04-06 | Routine/Partial Inspection | No Violations Noted | |
| 2167511 | Primary Facility | 2013-05-15 | Routine/Complete Inspection | No Violations Noted | |
| 2203320 | Primary Facility | 2013-09-05 | Routine/Complete Inspection | No Violations Noted | |
| 2554602 | Primary Facility | 2017-01-19 | Routine/Complete Inspection | No Violations Noted | Routine Inspection; 1/19/2017.
I entered the site at 10:42. At the time of the inspection one well was drilled and shut-in. The Charles McNamee B 7H (081-20376) was drilled but never produced. Inactive status for the Charles McNamee B 7H was granted on 10/29/2013. ESX11-081-0152 expires on 6/5/2017 (because of a major modification). Currently, the site remains at the originally permitted size, has not been restored or reduced, and no PCSM (Post Construction Stormwater Management) has been implemented on the site. The most recent update to the well site restoration assessment Anadarko provided on 12/22/2016 indicates infiltration testing was planned for 2016 and the site will be re-permitted in 2017. I recommend re-permitting the site to comply with PCSM requirements and implementing that plan including well site restoration. No Violations Noted. |
| 2761465 | Primary Facility | 2018-08-08 | Routine/Complete Inspection | No Violations Noted | Weather was 72° and cloudy at time of inspection. There were no Alta representatives on location at time of inspection. Well was shut in with no surface production equipment attached to it. Well had 1 0-10k psi analog pressure gauge attached to the cap. It read 0 psi at time of inspection. There was one annulus vent plumbed to surface that was closed in at time of inspection. No violations were noted at time of inspection. |
| 2854765 | Primary Facility | 2019-03-18 | Routine/Complete Inspection | No Violations Noted | One inactive well on location. The pressure gauge read 0 psi. No production equipment on location. No violations noted. |
For data sources see[8]