X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-081-20376

Well Details

Well ID: 37-081-20376
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Cascade Township
Operator Name: ARD OPR LLC
Well Pad ID: 145402
Farm/Lease Name: CHARLES J MCNAMEE
License Status: INACTIVE
Spud Date: 2010-11-02
Permit Date: 2010-10-15
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.425036
Longitude: -76.907792

For data sources see[1][2][3]

Well History

Date Event
2010-10-15 New Permit Application
2010-11-01 Performed Spud Operation
2010-12-17 Drilling Completion
2013-04-06 Perforation
2014-03-14 DEVIATED
2019-10-01 Inactive Well Request Granted

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-04-24 2013-04-24 7,181 925,606

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 BXL A Trican Well Service Gel Breaker Proprietary Proprietary 70.0 None
Bio Clear 1000 Trican Well Service Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 100.0 0.00047
Bio-Clear 5000 Polyethylene glycol 25322-68-3 70.0 0.03341
2,2-dibromo-3-nitrilopropionamide 10222-01-2 10.0 0.00477
Acid, Hydrochloric (3.5) Trican Well Service General Acidizing
Acid, Hydrochloric (3.5) Water 7732-18-5 85.0 None
Hydrochloric Acid 7647-01-0 15.0 None
TXP-11 Water 7732-18-5 60.0 None
Poly electrolyte NA 40.0 None
Inorganic chemical NA 20.0 None
Various chlorides 16887-00-6 30.0 None
FR-15 Paraffinic, Naphthenic Solvent 64742-47-8 25.0 0.01314
Proprietary Amide Proprietary 2.5 0.00131
Sand (Proppant) (lbs) Trican Well Service Proppant
TXP-8 Trican Well Service Friction Reducer Cationic water-soluble polymer emulsion Proprietary 100.0 None
WBO-2 Trican Well Service Gel Breaker Sodium persulfate 7775-27-1 100.0 None
Bio-Clear 5000 Trican Well Service Biocide
FEAC-20
DF-1 Trican Well Service De-foaming Agent Non-hazardous materials only in the product NA 100.0 None
WG-111L Trican Well Service Viscosifier; Gelant Light hydrotreated petroleum distillate 64742-47-8 60.0 None
Polysaccharide blend NA 60.0 None
Water Anadarko Carrier / Base Fluid 7732-18-5 100.0 84.05925
WXB-10 Trican Well Service Fracturing cross linker Borate salts 1319-33-1 60.0 None
Light hydrotreated petroleum distillate 64742-47-8 60.0 None
FR-15 Trican Well Service Friction Reducer
CS-1 Trican Well Service Clay Stabilizer Surfactant Proprietary 5.0 None
Propylene glycol 57-55-6 20.0 None
Blend Proprietary 25.0 None
Inorganic salts Proprietary 30.0 None
WBE-6 Trican Well Service Gel Breaker No hazardous ingredients NA 100.0 None
TXP-11 Trican Well Service Clay Stabilizer
TXP-10 Trican Well Service Scale Inhibitor Acrylate phosphonate copolymer Proprietary 40.0 None
Neutralized organic acid Proprietary 20.0 None
Water 7732-18-5 70.0 None
Propylene glycol 57-55-6 10.0 None
FEAC-20 Trican Well Service Iron Control Citric Acid 77-92-9 30.0 0.00206
Acetic Acid 64-19-7 50.0 0.00343
FR-14 Inorganic salt Proprietary 30.0 None
Acetic Acid 64-19-7 5.0 None
GBO-1 Trican Well Service Gel Breaker Sodium perborate tetrahydrate 10486-00-7 100.0 None
TXP-10
Acid, Hydrochloric (7.5) Trican Well Service General Acidizing Hydrochloric Acid 7647-01-0 7.5 None
AI-7NR Trican Well Service Corrosion Inhibitor Prop-2-yn-1-ol 107-19-7 1.0 0.00003000
WG-111L
Acid, Hydrochloric (7.5) Water 7732-18-5 92.5 None
WXB-10
CS-1
FR-14 Trican Well Service Friction Reducer
Sand (Proppant) (lbs) Quartz 14808-60-7 70.0 11.08116
Hexamethylenetretramine 100-97-0 1.0 0.1583
WG-111D Trican Well Service Water gellant Guar gum 9000-30-0 100.0 None

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 ANADARKO E&P ONSHORE LLC 0.00 0 0.00 0 0.00 0
2011 ANADARKO E&P ONSHORE LLC 0.00 0 0.00 0 0.00 0
2012 ANADARKO E&P ONSHORE LLC 0.00 0 0.00 0 0.00 0
2013 ANADARKO E&P ONSHORE LLC 0.00 0 0.00 0 0.00 0
2014 ANADARKO E&P ONSHORE LLC 0.00 0 0.00 0 0.00 0
2015 ANADARKO E&P ONSHORE LLC 0.00 0 0.00 0 0.00 0
2016 ANADARKO E&P ONSHORE LLC 0.00 0 0.00 0 0.00 0
2017 ARD OPR LLC 0.00 0 0.00 0 0.00 0
2019 ARD OPR LLC 0.00 0 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 ANADARKO E&P ONSHORE LLC Drill Cuttings 122.21 Tons LANDFILL 101397

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1920643 Primary Facility 2010-10-04 Routine/Partial Inspection No Violations Noted
1928743 Primary Facility 2010-11-19 Drilling/Alteration No Violations Noted
1933410 Primary Facility 2010-10-07 Drilling/Alteration No Violations Noted
1938085 Primary Facility 2010-12-18 Drilling/Alteration No Violations Noted
1943068 Primary Facility 2011-01-14 Routine/Partial Inspection No Violations Noted
2018142 Primary Facility 2011-11-08 Routine/Complete Inspection No Violations Noted
2057302 Primary Facility 2012-04-06 Routine/Partial Inspection No Violations Noted
2167511 Primary Facility 2013-05-15 Routine/Complete Inspection No Violations Noted
2203320 Primary Facility 2013-09-05 Routine/Complete Inspection No Violations Noted
2554602 Primary Facility 2017-01-19 Routine/Complete Inspection No Violations Noted Routine Inspection; 1/19/2017.

I entered the site at 10:42. At the time of the inspection one well was drilled and shut-in. The Charles McNamee B 7H (081-20376) was drilled but never produced. Inactive status for the Charles McNamee B 7H was granted on 10/29/2013. ESX11-081-0152 expires on 6/5/2017 (because of a major modification). Currently, the site remains at the originally permitted size, has not been restored or reduced, and no PCSM (Post Construction Stormwater Management) has been implemented on the site.

The most recent update to the well site restoration assessment Anadarko provided on 12/22/2016 indicates infiltration testing was planned for 2016 and the site will be re-permitted in 2017. I recommend re-permitting the site to comply with PCSM requirements and implementing that plan including well site restoration. No Violations Noted.

2761465 Primary Facility 2018-08-08 Routine/Complete Inspection No Violations Noted Weather was 72° and cloudy at time of inspection. There were no Alta representatives on location at time of inspection. Well was shut in with no surface production equipment attached to it. Well had 1 0-10k psi analog pressure gauge attached to the cap. It read 0 psi at time of inspection. There was one annulus vent plumbed to surface that was closed in at time of inspection. No violations were noted at time of inspection.
2854765 Primary Facility 2019-03-18 Routine/Complete Inspection No Violations Noted One inactive well on location. The pressure gauge read 0 psi. No production equipment on location. No violations noted.

For data sources see[8]

References