If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-081-20406 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.373722,"lon":-77.1045,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Lycoming | |
Municipality: Lewis Township | |
Operator Name: RANGE RESOURCES APPALACHIA LLC | |
Well Pad ID: 151965 | |
Farm/Lease Name: GOODWILL HUNTING CLUB UNIT | |
License Status: INACTIVE | |
Spud Date: 2011-06-22 | |
Permit Date: 2010-11-17 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.373722 | |
Longitude: -77.1045 |
Date | Event |
---|---|
2010-11-17 | New Permit Application |
2011-06-22 | Performed Spud Operation |
2011-10-06 | Drilling Completion |
2012-02-24 | Perforation |
2012-07-19 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-02-29 | 2012-02-29 | 8,906 | 2,233,960 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Biocide MC B 8650 | Multi-Chem Group | Antibacterial Agent | Glutaraldehyde | 111-30-8 | 50.00 | 0.00380000 | |
Methanol | 67-56-1 | 0.50 | 0.00004000 | |||||
Iron Control - WIC-641L | Weatherford | Prevents Precipitation | Citric acid | 77-92-9 | 70.00 | 0.00530000 | ||
Biocide MC B 8520 | Multi-Chem Group | Antibacterial Agent | Formaldehyde Amine | 56652-26-7 | 0.50 | 0.00010000 | ||
2-Amino-2-methylpropan-1-ol | 124-68-5 | 1.00 | 0.00020000 | |||||
4,4-Dimethyloxazolidine | 51200-87-4 | 78.00 | 0.01 | |||||
3,4,4-Trimethyloxazolidine | 75673-43-7 | 5.00 | 0.00090000 | |||||
35 HCL | Weatherford | Clean Perforations | Hydrochloric acid | 7647-01-0 | 35.00 | 0.04 | ||
Inhibitor - WAI-251LC | Weatherford | Protects Casing | Triethyl phosphate | 78-40-0 | 7.00 | 0.00010000 | ||
Poly(oxy-1,2-ethanediyl), alpha-(nonylphenyl)-omega-hydroxy-
, |
68412-54-4 | 10.00 | 0.00010000 | |||||
N,N-Dimethylformamide | 68-12-2 | 40.00 | 0.00050000 | |||||
Cinnamaldehyde (3-phenyl-2-propenal) | 104-55-2 | 10.00 | 0.00010000 | |||||
2-Butoxyethanol | 111-76-2 | 7.00 | 0.00010000 | |||||
Tar bases, quinoline derivatives, benzyl chloride-quaternized |
72480-70-7 | 13.00 | 0.00020000 | |||||
Ethylene glycol | 107-21-1 | 60.00 | 0.00080000 | |||||
Isopropanol | 67-63-0 | 7.00 | 0.00010000 | |||||
MX 588-2 | Multi-Chem Group | Scale Inhibitor | MX588-2 | 0.00 | 0.01 | |||
WFR-61LA | Weatherford | Friction Reducer | Sodium chloride | 7647-14-5 | 10.00 | 0.00170000 | ||
Petroleum Distillates | 40.00 | 0.00680000 | ||||||
Ammonium chloride | 12125-02-9 | 7.00 | 0.00120000 | |||||
Ethoxylated C12-16 alcohols | 68551-12-2 | 7.00 | 0.00120000 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | RANGE RESOURCES APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | RANGE RESOURCES APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | RANGE RESOURCES APPALACHIA LLC | 17,308.00 | 3 | 0.00 | 0 | 0.00 | 0 |
2013 | RANGE RESOURCES APPALACHIA LLC | 139,947.00 | 12 | 0.00 | 0 | 0.00 | 0 |
2014 | RANGE RESOURCES APPALACHIA LLC | 962,021.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | RANGE RESOURCES APPALACHIA LLC | 446,480.00 | 345 | 0.00 | 0 | 0.00 | 0 |
2016 | RANGE RESOURCES APPALACHIA LLC | 346,733.30 | 361 | 0.00 | 0 | 0.00 | 0 |
2017 | RANGE RESOURCES APPALACHIA LLC | 306,827.89 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | RANGE RESOURCES APPALACHIA LLC | 331,553.64 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | RANGE RESOURCES APPALACHIA LLC | 256,951.44 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | RANGE RESOURCES APPALACHIA LLC | Drilling Fluid Waste | 2,600.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2012 | RANGE RESOURCES APPALACHIA LLC | Fracing Fluid Waste | 4,000.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC006 |
2012 | RANGE RESOURCES APPALACHIA LLC | Drill Cuttings | 145.64 Tons | LANDFILL | 100955 |
2012 | RANGE RESOURCES APPALACHIA LLC | Fracing Fluid Waste | 2,880.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2013 | RANGE RESOURCES APPALACHIA LLC | Fracing Fluid Waste | 28.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2014 | RANGE RESOURCES APPALACHIA LLC | Produced Fluid | 528.45 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2014 | RANGE RESOURCES APPALACHIA LLC | Produced Fluid | 528.45 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2014 | RANGE RESOURCES APPALACHIA LLC | Produced Fluid | 1,995.74 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2014 | RANGE RESOURCES APPALACHIA LLC | Produced Fluid | 1,995.74 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2015 | RANGE RESOURCES APPALACHIA LLC | Produced Fluid | 623.71 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2015 | RANGE RESOURCES APPALACHIA LLC | Produced Fluid | 3,095.16 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2015 | RANGE RESOURCES APPALACHIA LLC | Produced Fluid | 623.71 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | RANGE RESOURCES APPALACHIA LLC | Produced Fluid | 3,095.16 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2016 | RANGE RESOURCES APPALACHIA LLC | Produced Fluid | 55.45 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2016 | RANGE RESOURCES APPALACHIA LLC | Other Oil & Gas Wastes | 32.64 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2016 | RANGE RESOURCES APPALACHIA LLC | Other Oil & Gas Wastes | 104.71 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2016 | RANGE RESOURCES APPALACHIA LLC | Produced Fluid | 487.35 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2016 | RANGE RESOURCES APPALACHIA LLC | Produced Fluid | 260.52 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2016 | RANGE RESOURCES APPALACHIA LLC | Produced Fluid | 55.45 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2017 | RANGE RESOURCES APPALACHIA LLC | Produced Fluid | 286.69 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017 | RANGE RESOURCES APPALACHIA LLC | Other Oil & Gas Wastes | 57.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017 | RANGE RESOURCES APPALACHIA LLC | Produced Fluid | 186.32 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018 | RANGE RESOURCES APPALACHIA LLC | Produced Fluid | 240.09 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2019 | RANGE RESOURCES APPALACHIA LLC | Produced Fluid | 98.36 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2019 | RANGE RESOURCES APPALACHIA LLC | Produced Fluid | 151.50 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1995763 | Primary Facility | 2011-08-15 | Drilling/Alteration | No Violations Noted | |
2054494 | Primary Facility | 2012-03-19 | Routine/Complete Inspection | Violation(s) Noted | Elevated conductivity related to spill in puddle on southeast side of the pad. vio to well |
2055291 | Primary Facility | 2012-03-26 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | some surface material removed from spill. liner, tanks and containment remain |
2070847 | Primary Facility | 2012-05-24 | Routine/Complete Inspection | No Violations Noted | |
2145140 | Primary Facility | 2013-02-27 | Routine/Complete Inspection | No Violations Noted | |
2212863 | Primary Facility | 2013-09-24 | Routine/Complete Inspection | No Violations Noted | NOT/Restoration Inspection. Site meets the plan specifications but does not have 70% perrenial growth |
2292620 | Primary Facility | 2014-07-23 | Routine/Complete Inspection | No Violations Noted | Notice of Termination Inspection; 7/23/2014. |
2354940 | Primary Facility | 2015-03-23 | Routine/Complete Inspection | No Violations Noted | At the time of inspection sunny sky, ~1” snow cover and ~20° F. |
2447757 | Primary Facility | 2015-12-23 | Routine/Complete Inspection | No Violations Noted | At the time of the inspection, the two wells onsite in production. The well site is well vegetated and can be considered permanently stabilized but does not meet the PCSM plans or restoration requirements. I recommend the NOT be denied until the above concerns can be addressed. The Well Site Restoration Report for the Goodwill A Unit (081-21547) contains no waste disposal information and is considered incomplete. No Violations Noted. |
2469357 | Primary Facility | 2016-03-29 | Routine/Complete Inspection | No Violations Noted | Routine inspection. No violations noted. |
2503909 | Primary Facility | 2016-07-20 | Routine/Complete Inspection | No Violations Noted | Routine Inspection; 7/20/2016.
Jared Rutt (DEP) and I entered the site at 14:00. At the time of the inspection, the two wells onsite were in production. Range Resources’ consultant was onsite managing the workover/snubbing unit. The crew was snubbing tubing into the Goodwill Hunting Club 5H well (081-20406) while the well was in production. Containment was installed under the service truck and the unit/rig itself. Some oily water was in the cellar after rigging down from the well. I asked the consultant to vacuum the oily water from the cellar before leaving the site. The well site has not been restored and the Well Site Restoration Reports have not been received although most of the stormwater concerns discussed in the last inspection report have been resolved. The ESCGP is currently expired but no additional earth disturbance is planned. No Violations Noted. |
2517262 | Primary Facility | 2016-09-07 | Routine/Complete Inspection | No Violations Noted | Arrived @ 11:00. Weather: sunny, light breeze, low humidity. This was a routine inspection. There were no personnel on site. There were two producing wells. Cellars were gravel filled:
Goodwill A Unit 06H Top gauge: 550 psi (0-10,000 psi analog), 13-3/8” x 9-5/8”: no combustible gas detected (Altair 5X gas meter calibrated 09/07/16). 9-5/8” x 5-1/2”: plumbed to 225-gallon polytank. 11%/volume combustible gas at polytank vent. Goodwill A Unit 05 Top gauge: 800 psi (0-10,000psi analog), ), 13-3/8” x 9-5/8”: no combustible gas detected, 9-5/8” x 5-1/2”: plumbed to 225-gallon polytank, no combustible gas detected. Left location @ 11:35. |
2707465 | Primary Facility | 2018-03-15 | Site Restoration | No Violations Noted | Well Site Restoration Inspection; 3/15/2018.
At the time of the inspection, two wells were in production. The well site is permanently stabilized and Post Construction Stormwater Management (PCSM)/ Restoration Plans have been implemented. I recommend the NOT for this ESCGP be approved. No violations noted. |
2856529 | Primary Facility | 2019-03-21 | Routine/Complete Inspection | No Violations Noted | Two wells staged for production. Methanol tanks near well heads. Two GPU's within containment. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2054494 | 635493 | 03/19/2012 | 2012-03-19 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety | |
2054494 | 635494 | 03/19/2012 | 2012-03-19 | 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. | Administrative | |
2054494 | 635495 | 03/19/2012 | 2012-03-19 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
635493 | 281989 | NOV - Notice of Violation | Comply/Closed | 2012-05-24 | |||
635494 | 281989 | NOV - Notice of Violation | Comply/Closed | 2012-05-24 | |||
635495 | 281989 | NOV - Notice of Violation | Comply/Closed | 2012-05-24 |
For data sources see[8]