37-081-20492

Well Details

Well ID: 37-081-20492
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Franklin Township
Operator Name: EXCO RESOURCES PA LLC
Well Pad ID: 150883
Farm/Lease Name: WARNER UNIT 2H
License Status: Inactive
Spud Date: 2011-06-24
Permit Date: 2011-01-10
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.237822
Longitude: -76.600561

For data sources see[1][2][3]

Well History

Date Event
2011-01-10 New Permit Application
2011-06-24 Performed Spud Operation
2011-12-07 Drilling Completion
2012-07-19 DEVIATED
2016-09-26 Inactive Well Request Granted

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2011 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2012 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2013 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2014 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2015 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2016 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2017 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2019 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 EXCO RESOURCES PA LLC Drilling Fluid Waste 2,700.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 EXCO RESOURCES PA LLC Drill Cuttings 81.26 Tons LANDFILL 301358
2018 EXCO RESOURCES PA LLC Produced Fluid 60.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1988045 Primary Facility 2011-07-15 Drilling/Alteration No Violations Noted
1999479 Primary Facility 2011-08-30 Follow-up Inspection Violation(s) Noted
2021361 Primary Facility 2011-11-22 Drilling/Alteration No Violations Noted
2064901 Primary Facility 2012-05-03 Routine/Complete Inspection No Violations Noted
2072051 Primary Facility 2012-05-31 Routine/Complete Inspection No Violations Noted
2077070 Primary Facility 2012-06-12 Routine/Complete Inspection No Violations Noted
2081349 Primary Facility 2012-07-02 Routine/Complete Inspection No Violations Noted
2091256 Primary Facility 2012-08-13 Drilling/Alteration No Violations Noted
2098757 Primary Facility 2012-09-11 Routine/Partial Inspection No Violations Noted
2123244 Primary Facility 2012-12-06 Routine/Complete Inspection No Violations Noted
2130026 Primary Facility 2013-01-10 Routine/Complete Inspection No Violations Noted
2132664 Primary Facility 2013-01-16 Follow-up Inspection No Violations Noted
2136666 Primary Facility 2013-01-24 Incident- Response to Accident or Event No Violations Noted
2152180 Primary Facility 2013-03-29 Routine/Complete Inspection No Violations Noted
2177919 Primary Facility 2013-06-25 Routine/Complete Inspection No Violations Noted
2184120 Primary Facility 2013-07-16 Routine/Complete Inspection No Violations Noted
2200829 Primary Facility 2013-08-13 Routine/Partial Inspection No Violations Noted diesel spill to pad. excavated and field corfirmed w/ PID. VIOIC to 1H
2435529 Primary Facility 2015-12-04 Routine/Complete Inspection No Violations Noted I arrived onsite at 09:51. Five of the six wells on the pad were in production. The tank pad (located to the southwest of the well pad) remains in place yet no work has been done on any of the wells since July 2013. According to the well records, drilling on the last well (081-20492) was completed on 12/7/2011 and there are no other active well permits for this well site. Section 3216 (c) requires that "within nine months after completion of drilling of a well, the owner or operator shall restore the well site." The Well Site Restoration assessment summary indicates that a new well permit was to be submitted to the Department Fall 2015. As of the date of this inspection report, no well permit applications are pending or have been issued according to eFacts. In order to bring the well site into compliance, the Department recommends that EXCO restore the well site in accordance with Section 3216(c) or comply with the restoration schedule as submitted.
2492454 Primary Facility 2016-06-09 Routine/Complete Inspection No Violations Noted Arrived @ 09:00. Weather sunny and warm. No company representatives were present at the time of the inspection. At the time of my inspection, two of the six wells on site (4H and 5H) were in production. This inspection was conducted in response to submission of an Application for Inactive Well Status for the Warner Unit 2H. The well was TD’ed in 2011, but not completed. The well was tagged and locked. Annular vents (13-3/8” x 9-5/8” and 9-5/8” x 5-1/2”) were monitored for methane with an Altair 5X gas multimeter (calibrated on 5/23/16). No violations were observed at the time of this inspection.
2498114 Primary Facility 2016-07-05 Administrative/File Review No Violations Noted An administrative review conducted on 7/5/2016 shows that Inspection 2348035 (conducted 2/27/2015) was entered in eFacts under XTO's Moser 8560H well (081-20402) in error. Inspection 2348035 should have been entered under EXCO's Warner 2H well (081-20492). The original eFacts inspection record cannot be changed, so this inspection report serves to correct and clarify the error.
2568243 Primary Facility 2017-03-06 Routine/Complete Inspection No Violations Noted Routine Inspection; 3/6/2017.Dan Harvey (DEP) and I arrived onsite at 09:00 and met with the landowner. Five of the six wells on the pad were in production. The tank pad has been removed and the site has been restored in accordance with the ESCGP which was upgraded to include Post Construction Stormwater Management (PCSM). The site is well vegetated but has not quite reached >70% uniform perennial vegetative growth.

We discussed the PCSM features and maximizing the amount of area that can be restored to crop production. A long rock pile and a steep water bar at the northwest corner (near the entrance off SR118) of the well pad have not been restored back to approximate original contours. I recommend moving the rock pile onto the well pad and smoothing the water bar/soil stockpile so that the area can return to agricultural production. The landowner and the operator have already coordinated on the removal of silt sock on the site so that the fields can be returned to agricultural production. No Violation

2817247 Primary Facility 2018-12-19 Routine/Complete Inspection No Violations Noted Five wells staged for production. One well in regulatory inactive status. Six GPUs not within containment. No leaks detected from production equipment. No violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1999479 619072 08/30/2011 2011-08-30 201G - Failure to post permit number, operator name, address, telephone number in a conspicuous manner at the site during drilling Administrative