37-081-20494

Well Details

Well ID: 37-081-20494
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Franklin Township
Operator Name: EXCO RESOURCES PA LLC
Well Pad ID: 150883
Farm/Lease Name: WARNER UNIT 5H
License Status:
Spud Date:
Permit Date: 2011-01-10
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.237744
Longitude: -76.600458

For data sources see[1][2][3]

Well History

Date Event
2011-01-10 New Permit Application
2011-06-24 Performed Spud Operation
2011-10-05 Drilling Completion
2012-07-19 DEVIATED
2012-12-21 Perforation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-12-29 2012-12-29 5,837 5,628,840

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Hydrochloric Acid Calfrac Well Services Clean Perforations Nonionic surfactant 5.00 0.00526000
Carbonic acid calcium salt (1:1) 471-34-1 1.00 0.02
Ammonium chloride 12125-02-9 10.00 0.00110000
Acetic acid 64-19-7 1.00 0.00018000
Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.03
Olefin 5.00 0.00010000
Quartz 14808-60-7 100.00 15.52
Formalin 50-00-0 0.10 0.00003000
Polyoxyalkylenes surfactant 5.00 0.00526000
Amine salt 5.00 0.00092000
Polyethylene glycol 25322-68-3 70.00 0.01
Fatty acids 30.00 0.00061000
Citric acid 77-92-9 60.00 0.00431000
Thiourea polymer 68527-49-1 30.00 0.00061000
Hydrochloric acid 7647-01-0 37.00 0.43
Ilmenite (FeTiO3), conc. 98072-94-7 0.10 0.00169000
Organic phosphonate 2 10.00 0.00184000
Sodium chloride 7647-14-5 1.00 0.00002000
Propargyl Alcohol 10.00 0.00020000
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 40.00 0.01
Methanol 67-56-1 60.00 0.00675000
Apatite 64476-38-6 0.10 0.00308000
Illite 12173-60-3 1.00 0.00457000
Polyacrylamide polymer 40.00 0.04
Goethite 1310-14-1 0.10 0.00586000
Biotite 1302-27-8 0.10 0.00308000
Organic phosphonate 1 30.00 0.00552000
Oxyalkylated polyamine 5.00 0.00092000
Polyoxyalkylenes 30.00 0.00061000
DAP-103 Calfrac Well Services Iron Control
Water BaseFluid/Mix Water Water 7732-18-5 100.00 83.91
Sand (Proppant) Calfrac Well Services Propping Agent
DAP-901 Calfrac Well Services Scale Inhibitor
DWP-944 Calfrac Well Services Biocide
DWP-612 Calfrac Well Services Friction Reducer
DAP-925 Calfrac Well Services Acid Corrosion Inhibitor

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2011 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2012 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2013 EXCO RESOURCES PA LLC 581,239.00 278 0.00 0 0.00 0
2014 EXCO RESOURCES PA LLC 883,279.00 365 0.00 0 0.00 0
2015 EXCO RESOURCES PA LLC 750,813.00 343 0.00 0 0.00 0
2016 EXCO RESOURCES PA LLC 520,800.00 279 0.00 0 0.00 0
2017 EXCO RESOURCES PA LLC 612,281.00 337 0.00 0 0.00 0
2018 EXCO RESOURCES PA LLC 570,881.00 364 0.00 0 0.00 0
2019 EXCO RESOURCES PA LLC 498,792.00 363 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 EXCO RESOURCES PA LLC Drilling Fluid Waste 1,119.77 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE EPA ID: 748-163
2011 EXCO RESOURCES PA LLC Drilling Fluid Waste 2,740.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2013 EXCO RESOURCES PA LLC Produced Fluid 547.60 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC009
2013 EXCO RESOURCES PA LLC Produced Fluid 80.95 Bbl REUSE OTHER THAN ROAD SPREADING
2013 EXCO RESOURCES PA LLC Produced Fluid 109.52 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC024
2013 EXCO RESOURCES PA LLC Produced Fluid 649.88 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013 EXCO RESOURCES PA LLC Fracing Fluid Waste 330.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2013 EXCO RESOURCES PA LLC Fracing Fluid Waste 7,042.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 EXCO RESOURCES PA LLC Produced Fluid 1,176.16 Bbl STORAGE PENDING DISPOSAL OR REUSE
2013 EXCO RESOURCES PA LLC Fracturing Fluid Waste 53.89 Tons LANDFILL 301358
2013 EXCO RESOURCES PA LLC Produced Fluid 892.83 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2014 EXCO RESOURCES PA LLC Produced Fluid 220.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2014 EXCO RESOURCES PA LLC Produced Fluid 110.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2014 EXCO RESOURCES PA LLC Produced Fluid 121.40 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC024
2014 EXCO RESOURCES PA LLC Produced Fluid 139.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015 EXCO RESOURCES PA LLC Produced Fluid 220.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2016 EXCO RESOURCES PA LLC Produced Fluid 100.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2017 EXCO RESOURCES PA LLC Produced Fluid 100.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2018 EXCO RESOURCES PA LLC Produced Fluid 50.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2019 EXCO RESOURCES PA LLC Produced Fluid 168.00 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2019 EXCO RESOURCES PA LLC Produced Fluid 50.00 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1999482 Primary Facility 2011-08-30 Follow-up Inspection No Violations Noted
2003908 Primary Facility 2011-09-19 Drilling/Alteration No Violations Noted
2012680 Primary Facility 2011-10-19 Drilling/Alteration No Violations Noted
2064904 Primary Facility 2012-05-03 Routine/Complete Inspection No Violations Noted
2072048 Primary Facility 2012-05-31 Routine/Complete Inspection No Violations Noted
2077076 Primary Facility 2012-06-12 Routine/Complete Inspection No Violations Noted
2081352 Primary Facility 2012-07-02 Routine/Complete Inspection No Violations Noted
2091242 Primary Facility 2012-08-13 Drilling/Alteration No Violations Noted
2098760 Primary Facility 2012-09-11 Routine/Partial Inspection No Violations Noted
2123251 Primary Facility 2012-12-06 Routine/Complete Inspection No Violations Noted
2130032 Primary Facility 2013-01-10 Routine/Complete Inspection No Violations Noted
2132667 Primary Facility 2013-01-16 Follow-up Inspection No Violations Noted
2136670 Primary Facility 2013-01-24 Incident- Response to Accident or Event No Violations Noted
2152167 Primary Facility 2013-03-29 Routine/Complete Inspection No Violations Noted
2177924 Primary Facility 2013-06-25 Routine/Complete Inspection No Violations Noted
2184123 Primary Facility 2013-07-16 Routine/Complete Inspection No Violations Noted
2200834 Primary Facility 2013-08-13 Routine/Partial Inspection No Violations Noted diesel spill to pad. excavated and field corfirmed w/ PID. VIOIC to 1H
2348045 Primary Facility 2015-02-27 Routine/Complete Inspection No Violations Noted At the time of inspection sunny sky, light snow cover and 7 degrees F.
2435532 Primary Facility 2015-12-04 Routine/Complete Inspection No Violations Noted I arrived onsite at 09:51. Five of the six wells on the pad were in production. The tank pad (located to the southwest of the well pad) remains in place yet no work has been done on any of the wells since July 2013. According to the well records, drilling on the last well (081-20492) was completed on 12/7/2011 and there are no other active well permits for this well site. Section 3216 (c) requires that "within nine months after completion of drilling of a well, the owner or operator shall restore the well site." The Well Site Restoration assessment summary indicates that a new well permit was to be submitted to the Department Fall 2015. As of the date of this inspection report, no well permit applications are pending or have been issued according to eFacts. In order to bring the well site into compliance, the Department recommends that EXCO restore the well site in accordance with Section 3216(c) or comply with the restoration schedule as submitted.
2492506 Primary Facility 2016-06-09 Routine/Complete Inspection No Violations Noted Arrived @ 09:00. Weather sunny and warm. No company representatives were present at the time of the inspection. Two of the six wells on site (4H and 5H) were in production.

Warner Unit 5H: Gravel cellar. Top gauge: 568 psi (digital), 5-1/2” gauge: 769 psi (digital). Annular vents (13-3/8” x 9-5/8” and 9-5/8” x 5-1/2”) were monitored for methane with an Altair 5X gas multimeter (calibrated on 5/23/16). No gas was detected. No violations were observed at the time of this inspection. Left location @ 09:30.

2568249 Primary Facility 2017-03-06 Routine/Complete Inspection No Violations Noted Routine Inspection; 3/6/2017.Dan Harvey (DEP) and I arrived onsite at 09:00 and met with the landowner. Five of the six wells on the pad were in production. The tank pad has been removed and the site has been restored in accordance with the ESCGP which was upgraded to include Post Construction Stormwater Management (PCSM). The site is well vegetated but has not quite reached >70% uniform perennial vegetative growth.

We discussed the PCSM features and maximizing the amount of area that can be restored to crop production. A long rock pile and a steep water bar at the northwest corner (near the entrance off SR118) of the well pad have not been restored back to approximate original contours. I recommend moving the rock pile onto the well pad and smoothing the water bar/soil stockpile so that the area can return to agricultural production. The landowner and the operator have already coordinated on the removal of silt sock on the site so that the fields can be returned to agricultural production. No Violation

2817254 Primary Facility 2018-12-18 Routine/Complete Inspection No Violations Noted Five wells staged for production. One well in regulatory inactive status. Six GPUs not within containment. No leaks detected from production equipment. No violations noted.

For data sources see[8]

References