37-081-20563

Well Details

Well ID: 37-081-20563
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Cogan House Township
Operator Name: ARD OPR LLC
Well Pad ID: 148464
Farm/Lease Name: H LYLE LANDON A 4H
License Status:
Spud Date:
Permit Date: 2011-04-27
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.412322
Longitude: -77.204633

For data sources see[1][2][3]

Well History

Date Event
2011-04-27 New Permit Application
2011-09-29 Performed Spud Operation
2012-08-24 New Permit Application
2013-02-14 Drilling Completion
2013-06-05 Perforation
2014-01-28 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-06-30 2013-07-06 7,360 3,539,680 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Water Anadarko Carrier/Base Fluid Water 7732-18-5 100 82.7159 29,538,700.0
Hydrochloric Acid (7.5%) Trican Well Service Acidizing Hydrochloric Acid 7647-01-0 7.5 0.0364543 13018.2
Bio-Clear 5000 Trican Well Service Biocide Polyethylene glycol 25322-68-3 70 0.016783 5993.38
2,2-dibromo-3-nitrilopropionamide 10222-01-2 10 0.00239757 856.197
FR-15 Trican Well Service Friction Reducer Paraffinic, Naphthenic Solvent 64742-47-8 25 0.0138156 4933.69
Proprietary Amide Proprietary 2.5 0.00138156 493.369
Sand (Proppant) Trican Well Service Proppant Quartz 14808-60-7 99 16.5453 5,908,500.0
Hexamethylenetretramine 100-97-0 1 0.167124 59681.8
AI-7NR Trican Well Service Corrosion Inhibitor Prop-2-yn-1-ol 107-19-7 1 0.00001869 6.676
Bio-Clear 1000 Trican Well Service Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 98 0.00010977 39.2
FEAC-20 Trican Well Service Iron Control Acetic Acid 64-19-7 50 0.00220595 787.768
Citric Acid 77-92-9 30 0.00132357 472.661

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 ANADARKO E&P ONSHORE LLC 0.00 0 0.00 0 0.00 0
2012 ANADARKO E&P ONSHORE LLC 0.00 0 0.00 0 0.00 0
2013 ANADARKO E&P ONSHORE LLC 294,791.00 102 0.00 0 0.00 0
2014 ANADARKO E&P ONSHORE LLC 486,676.00 365 0.00 0 0.00 0
2015 ANADARKO E&P ONSHORE LLC 168,961.00 217 0.00 0 0.00 0
2016 ANADARKO E&P ONSHORE LLC 287,697.00 361 0.00 0 0.00 0
2017 ARD OPR LLC 170,707.44 341 0.00 0 0.00 0
2018 ARD OPR LLC 115,441.92 319 0.00 0 0.00 0
2019 ARD OPR LLC 128,334.11 361 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 ANADARKO E&P ONSHORE LLC Produced Fluid 14,466.11 Bbl REUSE OTHER THAN ROAD SPREADING
2014 ANADARKO E&P ONSHORE LLC Produced Fluid 13,273.93 Bbl REUSE OTHER THAN ROAD SPREADING
2015 ANADARKO E&P ONSHORE LLC Produced Fluid 655.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 ANADARKO E&P ONSHORE LLC Produced Fluid 47.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2015 ANADARKO E&P ONSHORE LLC Produced Fluid 2,085.10 Bbl REUSE OTHER THAN ROAD SPREADING
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 724.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 219.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 26.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 317.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 1,526.11 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 383.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 2,537.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2017 ANADARKO E&P ONSHORE LLC Produced Fluid 2,257.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 ANADARKO E&P ONSHORE LLC Produced Fluid 68.00 Bbl INJECTION DISPOSAL WELL 34-031-27177
2017 ANADARKO E&P ONSHORE LLC Produced Fluid 26.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119
2017 ANADARKO E&P ONSHORE LLC Produced Fluid 600.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2017 ARD OPR LLC Produced Fluid 278.75 Bbl REUSE (AT WELL PAD)
2017 ANADARKO E&P ONSHORE LLC Produced Fluid 595.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 ARD OPR LLC Produced Fluid 464.45 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 ARD OPR LLC Produced Fluid 1,259.56 Bbl REUSE (AT WELL PAD)
2019 ARD OPR LLC Produced Fluid 140.62 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 ARD OPR LLC Produced Fluid 2,282.64 Bbl REUSE (AT WELL PAD)
2019 ARD OPR LLC Servicing Fluid 29.00 Bbl REUSE (AT WELL PAD)
2019 ARD OPR LLC Produced Fluid 68.84 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2008905 Primary Facility 2011-10-06 Drilling/Alteration No Violations Noted
2063653 Primary Facility 2012-04-30 Routine/Complete Inspection No Violations Noted
2101643 Primary Facility 2012-09-19 Drilling/Alteration No Violations Noted
2124932 Primary Facility 2012-12-19 Drilling/Alteration No Violations Noted
2181527 Primary Facility 2013-07-08 Routine/Complete Inspection No Violations Noted
2325602 Primary Facility 2014-11-25 Incident- Response to Accident or Event Violation(s) Noted On 11/22/2014 Mark Barbier (Anadarko) reported approximately 20 barrels of produced fluid and associated production gas was discharged (uncontrolled to the atmosphere) from the 4H well due to a pipe joint failure on the wellhead. According to the call, the well was shut in manually by Anadarko personnel.
2521467 Primary Facility 2016-09-15 Routine/Complete Inspection No Violations Noted Routine Inspection; 9/15/2016.

I entered the location at 13:40 and began the inspection. At the time of the inspection, five producing wells (081-21014, 081-20562, 081-21015, 081-20563, and 081-21016) and one plugged well were located onsite. The well site was in good condition and no E&S issues were observed. The site has no active well permits that have not been drilled.

ESX10-081-0041 previously expired and ESG29-081-16-0003 is currently active. The wells onsite were drilled from 2011 to 2012 and the well site has not been restored. Anadarko’s most recent restoration timeline submission indicates PCSM will be permitted in 2016 (as noted above) and installed in 2017.

The Department considers a well site to be restored under Section 3216(c) of the 2012 Oil and Gas Act when the oil or gas owners or operators meet the following:

1. All permanent post construction stormwater control features as   the Post Construction Stormwater Management/Site Restoration Plan are in place.

2. Remaining impervious are

2575494 Primary Facility 2017-03-21 Routine/Complete Inspection No Violations Noted Routine inspection of unvonventional well pad in production. A-4H well is in production with no detectable methane emissions. Bubbling noted on location, later discovered to be a phenomenon of the thawing ground. Methane emissions not detected by GES during sampling of location.
2578513 Primary Facility 2017-03-23 Routine/Complete Inspection No Violations Noted Routine inspection of unconventional well in production. No violations noted at time of inspection.
2581628 Primary Facility 2017-03-28 Follow-up Inspection No Violations Noted Follow up inspection of an unconventional well pad in production. Some bubbling still noted on the pad. 0% combustible gas emissions detected at time of inspection. No violations noted at time of inspection.
2587701 Primary Facility 2017-04-12 Follow-up Inspection No Violations Noted Follow up inspection of location and wells following discovery of a bubbling phenomenon on location. Phenomenon appears to have subsided, No methane detected during inspection. No violations noted at time of inspection.
2592384 Primary Facility 2017-05-03 Routine/Complete Inspection Violation(s) Noted Inspection of 11 3/4" x 8 5/8" annulus vent on well. Methane detected at time of inspection. Cited defective cement.
2643971 Primary Facility 2017-10-04 Routine/Complete Inspection No Violations Noted Weather was 57° and sunny at time of inspection. 5 1/2 x 9 5/8 annulus is plumbed to the surface and has a digital gauge attached. Gauge read 137 PSI at time of inspection. The second annular event is plumbed to the surface with an analog 0 to 1000 psi gauge attached. Gauge had a reading of zero psi at time of inspection. Well had had a digital pressure gauge attached above the swab valve that read 1104 PSI.
2687251 Primary Facility 2018-01-22 Incident- Response to Accident or Event Violation(s) Noted Spill response inspection; 1/22/2018.

Mark Barbier (ARD Operating) called the Department at 18:01 on 1/20/2018 to report the release of 176 gallons of a 30% methanol/water solution. The methanol/water mixture was released from a failed ball valve on the 4H(081-20563). 250 gallons of the released methanol/water mixture and melt water was vacuumed from the 3H well cellar later that night.

At approximately 13:45 on 1/22/2018, I met onsite with Mark Barbier and Rick Hall (both ARD). They showed me the failed valve leading to the 4H well and the excavated flow path into the 3H cellar. Material from the flow path across several feet of the pad surface had been excavated and placed in a overpack drum for disposal. The material under the excavation was frozen solid. I was only able to drive a digging bar 1/4 inch into the frozen surface. Water was streaming into the well cellars from the well pad surface due to warming temperatures and runoff. I was told the cellar would continue to be vacuumed. The conditio

2844657 Primary Facility 2019-02-26 Routine/Complete Inspection No Violations Noted Five wells staged for production. One well plugged. No free standing liquid on a day temperatures were below freezing. No leaks.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2325602 711559 11/25/2014 2014-11-25 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. Environmental Health & Safety On 11/22/2014 Mark Barbier (Anadarko) reported approximately 20 barrels of produced fluid and associated production gas was discharged (uncontrolled to the atmosphere) from the 4H well due to a pipe joint failure on the wellhead. According to the call, the well was shut in manually by Anadarko pers
2325602 711560 11/25/2014 2014-11-25 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. Environmental Health & Safety On 11/22/2014 Mark Barbier (Anadarko) reported approximately 20 barrels of produced fluid and associated production gas was discharged (uncontrolled to the atmosphere) from the 4H well due to a pipe joint failure on the wellhead. According to the call, the well was shut in manually by Anadarko pers
2325602 711561 11/25/2014 2014-11-25 78.57 - Failure to post pit approval number Administrative On 11/22/2014 Mark Barbier (Anadarko) reported approximately 20 barrels of produced fluid and associated production gas was discharged (uncontrolled to the atmosphere) from the 4H well due to a pipe joint failure on the wellhead. According to the call, the well was shut in manually by Anadarko pers
2325602 711562 11/25/2014 2014-11-25 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety On 11/22/2014 Mark Barbier (Anadarko) reported approximately 20 barrels of produced fluid and associated production gas was discharged (uncontrolled to the atmosphere) from the 4H well due to a pipe joint failure on the wellhead. According to the call, the well was shut in manually by Anadarko pers
2592384 785351 2017-05-03 78a86 Environmental Health & Safety
2687251 806757 2018-01-22 2018-02-09 CSL 402(b) Environmental Health & Safety The discharge of methanol to the well pad surface represents the potential to pollute Waters of the Commonwealth.
2687251 806758 2018-01-22 2018-02-09 78a54 Environmental Health & Safety The operator failed to dispose of residual waste in a manner that prevents pollution of the Waters of the Commonwealth.
2687251 806759 2018-01-22 2018-02-09 SWMA 301 Environmental Health & Safety The operator failed to properly store, transport, or dispose of residual waste when a solution of methanol/eater was discharged to the well pad surface.

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
711559 318023 NOV - Notice of Violation Comply/Closed 2015-06-18
711560 318023 NOV - Notice of Violation Comply/Closed 2015-06-18
711561 318023 NOV - Notice of Violation Comply/Closed 2015-06-18
711562 318023 NOV - Notice of Violation Comply/Closed 2015-06-18
806757 361021 NOV - Notice of Violation 2018-02-09
806758 361021 NOV - Notice of Violation 2018-02-09
806759 361021 NOV - Notice of Violation 2018-02-09

For data sources see[8]