37-081-20671

Well Details

Well ID: 37-081-20671
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Cascade Township
Operator Name: ARD OPR LLC
Well Pad ID: 149519
Farm/Lease Name: WALLIS RUN HUNTING CLUB A 6H
License Status:
Spud Date:
Permit Date: 2011-08-04
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.446439
Longitude: -76.837681

For data sources see[1][2][3]

Well History

Date Event
2011-08-04 New Permit Application
2011-09-01 Performed Spud Operation
2012-06-21 New Permit Application
2012-09-02 Drilling Completion
2013-08-24 Perforation
2014-02-19 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-09-05 2013-09-16 7,684 5,129,800 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand (Proppant) Trican Well Service Proppant Hexamethylenetretramine 100-97-0 1 0.139224 70159.6
Quartz 14808-60-7 99 13.7832 6,945,800.0
Aqucar DB 5 Trican Well Service Biocide Sodium bromide 7647-15-6 1.5 0.000669274 337.27
Dibromoacetonitrile 3252-43-5 50 0.0223091 11242.3
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 5 0.00223091 1124.23
Polyethylene glycol 25322-68-3 65.2 0.0290911 14660
Water Anadarko Carrier/Base Fluid Water 7732-18-5 100 84.9482 42,808,200.0
AI-7NR Trican Well Service Corrosion Inhibitor Prop-2-yn-1-ol 107-19-7 1 0.00003842 19.36
FR-15 Trican Well Service Friction Reducer Proprietary Amide Proprietary 2.5 0.00182028 917.299
Paraffinic, Naphthenic Solvent 64742-47-8 25 0.0182028 9172.99
FEAC-20 Trican Well Service Iron Control Acetic Acid 64-19-7 50 0.00453339 2284.53
Citric Acid 77-92-9 30 0.00272004 1370.72
Bio-Clear 1000 Trican Well Service Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 98 0.000155576 78.4
Hydrochloric Acid (7.5%) Trican Well Service Acidizing Hydrochloric Acid 7647-01-0 7.5 0.0749163 37752.8
Water 7732-18-5 92.5 0.923967 465618

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 ANADARKO E&P ONSHORE LLC 0.00 0 0.00 0 0.00 0
2012 ANADARKO E&P ONSHORE LLC 0.00 0 0.00 0 0.00 0
2013 ANADARKO E&P ONSHORE LLC 0.00 0 0.00 0 0.00 0
2014 ANADARKO E&P ONSHORE LLC 2,330,549.00 357 0.00 0 0.00 0
2015 ANADARKO E&P ONSHORE LLC 544,722.00 124 0.00 0 0.00 0
2016 ANADARKO E&P ONSHORE LLC 821,878.00 365 0.00 0 0.00 0
2017 ARD OPR LLC 336,206.79 365 0.00 0 0.00 0
2018 ARD OPR LLC 260,872.74 357 0.00 0 0.00 0
2019 ARD OPR LLC 193,053.31 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 ANADARKO E&P ONSHORE LLC Drill Cuttings 381.97 Tons LANDFILL 301626
2014 ANADARKO E&P ONSHORE LLC Produced Fluid 7,315.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 ANADARKO E&P ONSHORE LLC Produced Fluid 1,991.23 Bbl REUSE OTHER THAN ROAD SPREADING
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 820.95 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 109.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 33.00 Bbl STORAGE PENDING DISPOSAL OR REUSE
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 349.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2017 ANADARKO E&P ONSHORE LLC Produced Fluid 346.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 ANADARKO E&P ONSHORE LLC Produced Fluid 57.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119
2017 ARD OPR LLC Produced Fluid 56.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2017 ARD OPR LLC Produced Fluid 70.98 Bbl REUSE (AT WELL PAD)
2017 ANADARKO E&P ONSHORE LLC Produced Fluid 240.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 ARD OPR LLC Produced Fluid 31.81 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 ARD OPR LLC Produced Fluid 431.14 Bbl REUSE (AT WELL PAD)
2019 ARD OPR LLC Produced Fluid 507.83 Bbl REUSE (AT WELL PAD)
2019 ARD OPR LLC Other Oil & Gas Wastes 0.26 Bbl REUSE (AT WELL PAD)
2019 ARD OPR LLC Produced Fluid 53.28 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2018132 Primary Facility 2011-11-08 Routine/Complete Inspection No Violations Noted
2053006 Primary Facility 2012-03-21 Routine/Partial Inspection No Violations Noted
2083377 Primary Facility 2012-07-11 Routine/Complete Inspection No Violations Noted
2085798 Primary Facility 2012-07-23 Drilling/Alteration No Violations Noted
2094761 Primary Facility 2012-08-21 Routine/Complete Inspection No Violations Noted
2201531 Primary Facility 2013-09-04 Routine/Complete Inspection No Violations Noted
2485616 Primary Facility 2016-05-19 Routine/Complete Inspection No Violations Noted Routine Inspection; 5/17/2016.

I entered the location at 10:18 and began the inspection. At the time of the inspection, the Wallis Run Hunting Club A 2H (081-20669), 4H (081-20670), 5H (081-20961), and 6H (081-20971) wells were in production. The well pad area and access road are stabilized and no erosion was noted. The well site remains at its originally constructed size and has not been restored. The ESCGP expired on 6/30/2015. The revised restoration assessment indicates this site will be re-permitted sometime in 2016 and those revisions will be implemented sometime in 2017.

The Department considers a well site to be restored under Section 3216(c) of the 2012 Oil and Gas Act when the oil or gas owners or operators meet the following:

1. All permanent post construction stormwater control features as identified in the Post Construction Stormwater Management/Site Restoration Plan are in place.

2. Remaining impervious areas are minimized. See Section 102.8 (b)(4). Impervious areas include, but are

2568270 Primary Facility 2017-03-06 Routine/Complete Inspection No Violations Noted
2842718 Primary Facility 2019-02-21 Routine/Complete Inspection No Violations Noted Weather: 36 degrees partly cloudy. Fours wells staged for production phase. Four each sand and water separators within polyurethane coated Styrofoam. Main GPU and double walled production tank on location. Salt treatment fluid tank staged near well heads. Tank within containment. No leaks detected from production equipment. No violations noted.

For data sources see[8]