If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-081-20830 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.409414,"lon":-76.933272,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Lycoming | |
Municipality: Gamble Township | |
Operator Name: ARD OPR LLC | |
Well Pad ID: 147969 | |
Farm/Lease Name: CLEARVIEW HUNTING CLUB A 5H | |
License Status: | |
Spud Date: | |
Permit Date: 2012-01-17 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.409414 | |
Longitude: -76.933272 |
Date | Event |
---|---|
2012-01-17 | New Permit Application |
2012-01-31 | Performed Spud Operation |
2012-02-01 | Drilling Completion |
2013-03-22 | New Permit Application |
2013-05-12 | Drilling Completion |
2013-05-23 | NEWLY DRILLED |
2013-08-02 | Perforation |
2013-11-08 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-08-14 | 2013-08-25 | 7,460 | 2,891,710 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Sand (Proppant) | Trican Well Service | Proppant | Hexamethylenetretramine | 100-97-0 | 1 | 0.189844 | 56961.2 |
Quartz | 14808-60-7 | 99 | 18.7946 | 5,639,160.0 | ||||
FEAC-20 | Trican Well Service | Iron Control | Citric Acid | 77-92-9 | 30 | 0.00126025 | 378.129 | |
Acetic Acid | 64-19-7 | 50 | 0.00210042 | 630.214 | ||||
Hydrochloric Acid (7.5%) | Trican Well Service | Acidizing | Hydrochloric Acid | 7647-01-0 | 7.5 | 0.0347103 | 10414.6 | |
Bio-Clear 1000 | Trican Well Service | Biocide | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 98 | 0.00009472 | 28.42 | |
AI-7NR | Trican Well Service | Corrosion Inhibitor | Prop-2-yn-1-ol | 107-19-7 | 1 | 0.00001780 | 5.341 | |
FR-15 | Trican Well Service | Friction Reducer | Paraffinic, Naphthenic Solvent | 64742-47-8 | 25 | 0.0187429 | 5623.65 | |
Proprietary Amide | Proprietary | 2.5 | 0.00187429 | 562.365 | ||||
Water | Anadarko | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 80.4265 | 24,131,300.0 | |
Bio-Clear 5000 | Trican Well Service | Biocide | Polyethylene glycol | 25322-68-3 | 70 | 0.0316799 | 9505.29 | |
2,2-dibromo-3-nitrilopropionamide | 10222-01-2 | 10 | 0.00452569 | 1357.9 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2012 | ANADARKO E&P ONSHORE LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | ANADARKO E&P ONSHORE LLC | 430,680.00 | 80 | 0.00 | 0 | 0.00 | 0 |
2014 | ANADARKO E&P ONSHORE LLC | 840,964.00 | 274 | 0.00 | 0 | 0.00 | 0 |
2015 | ANADARKO E&P ONSHORE LLC | 441,214.00 | 348 | 0.00 | 0 | 0.00 | 0 |
2016 | ANADARKO E&P ONSHORE LLC | 182,263.00 | 362 | 0.00 | 0 | 0.00 | 0 |
2017 | ARD OPR LLC | 118,503.07 | 291 | 0.00 | 0 | 0.00 | 0 |
2018 | ARD OPR LLC | 91,589.89 | 357 | 0.00 | 0 | 0.00 | 0 |
2019 | ARD OPR LLC | 80,882.06 | 361 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | ANADARKO E&P ONSHORE LLC | Drill Cuttings | 21.79 Tons | LANDFILL | 301626 |
2013 | ANADARKO E&P ONSHORE LLC | Drill Cuttings | 670.77 Tons | LANDFILL | 301626 |
2013 | ANADARKO E&P ONSHORE LLC | Drill Cuttings | 44.58 Tons | LANDFILL | 100955 |
2013 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 6,671.57 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 8,850.95 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 856.75 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 1,328.25 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2015 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 3,377.51 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 67.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
2016 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 1,214.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2016 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 96.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2016 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 63.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2016 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 848.72 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2017 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 528.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 67.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
2017 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 173.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2017 | ARD OPR LLC | Produced Fluid | 49.68 Bbl | REUSE (AT WELL PAD) | |
2017 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 248.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018 | ARD OPR LLC | Produced Fluid | 38.68 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018 | ARD OPR LLC | Produced Fluid | 53.09 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018 | ARD OPR LLC | Produced Fluid | 275.19 Bbl | REUSE (AT WELL PAD) | |
2019 | ARD OPR LLC | Produced Fluid | 533.61 Bbl | REUSE (AT WELL PAD) | |
2019 | ARD OPR LLC | Servicing Fluid | 42.90 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2062867 | Primary Facility | 2012-04-25 | Routine/Complete Inspection | No Violations Noted | |
2198917 | Primary Facility | 2013-08-26 | Routine/Complete Inspection | Violation(s) Noted | |
2206921 | Primary Facility | 2013-09-24 | Routine/Complete Inspection | No Violations Noted | |
2236984 | Primary Facility | 2014-01-14 | Incident- Response to Accident or Event | No Violations Noted | Violations pending for 081-20517 (6H) well. produced water spill to the pad. |
2465514 | Primary Facility | 2016-03-16 | Routine/Complete Inspection | No Violations Noted | At the time of the inspection, three wells were in production while the fourth (081-20518) was granted inactive status on 10/29/2013. The well site is currently well vegetated and shows no signs of erosion. The well site remains at the originally constructed size and has not been restored as indicated in the permitted plans. The requirement under Section 3216 (c) of the Oil and Gas Act requires that "within nine months after completion of drilling of a well, the owner or operator shall restore the well site."
The approved plans call for a portion of the well site to be scarified and production facilities are installed where the site is to be scarified. I recommend re-permitting the site to incorporate a feasible restoration of the site. No Violations Noted |
2524916 | Primary Facility | 2016-10-03 | Routine/Complete Inspection | No Violations Noted | Remarks Arrived @ 14:30. Weather: windy and cloudy. There were 3 producing wells and 1 plugged well in a linear array on location. Lease operator Kevin Barr and automation tech Matt Musgrave were onsite when I arrived. Water injection and plunger systems were in use on the three production wells to limit salt build-up. The water injection plumbing was covered in silver insulation material, gas and water were plumbed to the GPUs. A-5H, in production. Cellar water-filled, no bubbles. Top gauge: ¿ 850 psi, (0-10,000 psi, analog). One annulus, shut-in, 0psi (digital). This well has a bypass plunger. |
2698677 | Primary Facility | 2018-02-27 | Routine/Complete Inspection | No Violations Noted | Weather was 36° and sunny at time of inspection. There were no ARD representative on location at time of inspection. Well had a digital gauge on the tubing, the production casing and the 5 1/2 x 9 5/8 annulus vent. Tubing pressure was 769 psi, casing was 792 and the annulus pressure was 1 psi at time of inspection. There were no other annulus vents plumbed to surface. No violations were noted at time of inspection. |
2854746 | Primary Facility | 2019-03-18 | Routine/Complete Inspection | No Violations Noted | Weather fair @ 39°F. Four wells on location and three wells staged for production. Well 081-20518 is granted regulatory inactive status. Three GPUs within polyurethane/foam containment. No leaks detected. No violations noted. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2198917 | 676016 | 08/26/2013 | 2013-08-26 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety | |
2198917 | 676017 | 08/26/2013 | 2013-08-26 | 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. | Administrative | Efacts not compatible- failure to contain pollutional substances in a tank or series of tanks |
2198917 | 676018 | 08/26/2013 | 2013-08-26 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | |
2198917 | 676019 | 08/26/2013 | 2013-08-26 | 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used | Administrative | 3218.2(a)(2) |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
676016 | 301280 | NOV - Notice of Violation | Comply/Closed | 2013-10-01 | |||
676017 | 301280 | NOV - Notice of Violation | Comply/Closed | 2013-10-01 | |||
676018 | 301280 | NOV - Notice of Violation | Comply/Closed | 2013-10-01 | |||
676019 | 301280 | NOV - Notice of Violation | Comply/Closed | 2013-10-01 |