37-081-21016

Well Details

Well ID: 37-081-21016
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Cogan House Township
Operator Name: ARD OPR LLC
Well Pad ID: 148464
Farm/Lease Name: H LYLE LANDON A 5H
License Status:
Spud Date:
Permit Date: 2012-08-24
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.412319
Longitude: -77.204689

For data sources see[1][2][3]

Well History

Date Event
2012-08-24 New Permit Application
2012-09-15 Performed Spud Operation
2013-02-27 Drilling Completion
2013-06-06 Perforation
2014-03-05 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-06-20 2013-06-29 7,376 3,554,540 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FEAC-20 Trican Well Service Iron Control Acetic Acid 64-19-7 50 0.00285374 1024.1
Citric Acid 77-92-9 30 0.00171224 614.459
AI-7NR Trican Well Service Corrosion Inhibitor Prop-2-yn-1-ol 107-19-7 1 0.00002418 8.679
Water Anadarko Carrier/Base Fluid Water 7732-18-5 100 82.6574 29,662,600.0
Bio-Clear 5000 Trican Well Service Biocide 2,2-dibromo-3-nitrilopropionamide 10222-01-2 10 0.00238866 857.198
Polyethylene glycol 25322-68-3 70 0.0167206 6000.39
Sand (Proppant) Trican Well Service Proppant Hexamethylenetretramine 100-97-0 1 0.166287 59674
Quartz 14808-60-7 99 16.4624 5,907,730.0
FR-15 Trican Well Service Friction Reducer Paraffinic, Naphthenic Solvent 64742-47-8 25 0.013249 4754.56
Proprietary Amide Proprietary 2.5 0.0013249 475.456
Hydrochloric Acid (7.5%) Trican Well Service Acidizing Hydrochloric Acid 7647-01-0 7.5 0.0471592 16923.7
Bio-Clear 1000 Trican Well Service Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 98 0.000106503 38.22

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 ANADARKO E&P ONSHORE LLC 0.00 0 0.00 0 0.00 0
2013 ANADARKO E&P ONSHORE LLC 219,827.00 102 0.00 0 0.00 0
2014 ANADARKO E&P ONSHORE LLC 390,386.00 365 0.00 0 0.00 0
2015 ANADARKO E&P ONSHORE LLC 139,296.00 218 0.00 0 0.00 0
2016 ANADARKO E&P ONSHORE LLC 209,161.00 361 0.00 0 0.00 0
2017 ARD OPR LLC 131,044.16 341 0.00 0 0.00 0
2018 ARD OPR LLC 88,772.45 317 0.00 0 0.00 0
2019 ARD OPR LLC 104,698.33 359 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 ANADARKO E&P ONSHORE LLC Drill Cuttings 569.88 Tons LANDFILL 301626
2013 ANADARKO E&P ONSHORE LLC Produced Fluid 19,459.48 Bbl REUSE OTHER THAN ROAD SPREADING
2014 ANADARKO E&P ONSHORE LLC Produced Fluid 15,016.88 Bbl REUSE OTHER THAN ROAD SPREADING
2015 ANADARKO E&P ONSHORE LLC Produced Fluid 678.52 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 ANADARKO E&P ONSHORE LLC Produced Fluid 48.40 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2015 ANADARKO E&P ONSHORE LLC Produced Fluid 2,384.57 Bbl REUSE OTHER THAN ROAD SPREADING
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 305.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 687.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 192.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 1,274.01 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 20.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 298.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2016 ANADARKO E&P ONSHORE LLC Produced Fluid 2,435.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2017 ANADARKO E&P ONSHORE LLC Produced Fluid 465.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2017 ANADARKO E&P ONSHORE LLC Produced Fluid 1,745.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 ANADARKO E&P ONSHORE LLC Produced Fluid 53.00 Bbl INJECTION DISPOSAL WELL 34-031-27177
2017 ANADARKO E&P ONSHORE LLC Produced Fluid 20.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119
2017 ARD OPR LLC Produced Fluid 211.31 Bbl REUSE (AT WELL PAD)
2017 ANADARKO E&P ONSHORE LLC Produced Fluid 441.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 ARD OPR LLC Produced Fluid 463.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 ARD OPR LLC Produced Fluid 1,240.79 Bbl REUSE (AT WELL PAD)
2019 ARD OPR LLC Produced Fluid 140.59 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 ARD OPR LLC Produced Fluid 2,709.26 Bbl REUSE (AT WELL PAD)
2019 ARD OPR LLC Servicing Fluid 40.60 Bbl REUSE (AT WELL PAD)
2019 ARD OPR LLC Produced Fluid 68.83 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2101646 Primary Facility 2012-09-19 Drilling/Alteration No Violations Noted
2124931 Primary Facility 2012-12-19 Drilling/Alteration No Violations Noted
2181528 Primary Facility 2013-07-08 Routine/Complete Inspection No Violations Noted
2325608 Primary Facility 2014-11-25 Incident- Response to Accident or Event No Violations Noted On 11/22/2014 Mark Barbier (Anadarko) reported approximately 20 barrels of produced fluid and associated production gas was discharged (uncontrolled to the atmosphere) from the 4H well due to a pipe joint failure on the wellhead. According to the call, the well was shut in manually by Anadarko personnel.
2521469 Primary Facility 2016-09-15 Routine/Complete Inspection No Violations Noted Routine Inspection; 9/15/2016.

I entered the location at 13:40 and began the inspection. At the time of the inspection, five producing wells (081-21014, 081-20562, 081-21015, 081-20563, and 081-21016) and one plugged well were located onsite. The well site was in good condition and no E&S issues were observed. The site has no active well permits that have not been drilled.

ESX10-081-0041 previously expired and ESG29-081-16-0003 is currently active. The wells onsite were drilled from 2011 to 2012 and the well site has not been restored. Anadarko’s most recent restoration timeline submission indicates PCSM will be permitted in 2016 (as noted above) and installed in 2017.

The Department considers a well site to be restored under Section 3216(c) of the 2012 Oil and Gas Act when the oil or gas owners or operators meet the following:

1. All permanent post construction stormwater control features as   the Post Construction Stormwater Management/Site Restoration Plan are in place.

2. Remaining impervious are

2575465 Primary Facility 2017-03-21 Routine/Complete Inspection No Violations Noted Routine inspection of unvonventional well pad in production. A-5H well is in production with no detectable methane emissions. Bubbling noted on location, later discovered to be a phenomenon of the thawing ground. Methane emissions not detected by GES during sampling of location.
2578524 Primary Facility 2017-03-23 Routine/Complete Inspection No Violations Noted Routine inspection of unconventional well in production. No violations noted at time of inspection.
2581694 Primary Facility 2017-03-28 Follow-up Inspection No Violations Noted Follow up inspection of an unconventional well pad in production. Some bubbling still noted on the pad. 0% combustible gas emissions detected at time of inspection. No violations noted at time of inspection.
2584332 Primary Facility 2017-04-12 Follow-up Inspection No Violations Noted Follow up inspection of location and wells following discovery of a bubbling phenomenon on location. Phenomenon appears to have subsided, No methane detected during inspection. No violations noted at time of inspection.
2590155 Primary Facility 2017-05-03 Routine/Complete Inspection No Violations Noted Routine inspection of unconvnetional well in porduction. No violations noted at time of inspection.
2592432 Primary Facility 2017-05-03 Routine/Complete Inspection No Violations Noted Inspection of 11 3/4" x 8 5/8" annulus vent on well. 0% methane detected at time of inspection. Well tag missing, being replaced. No violations noted at time of inspection.
2643973 Primary Facility 2017-10-04 Routine/Complete Inspection Violation(s) Noted Weather was 57° and sunny at time of inspection. 5 1/2 x 9 5/8 annulus is plumbed to the surface and has a digital gauge attached. Gauge read 9 PSI at time of inspection. The second annular event is plumbed to the surface with an analog 0 to 1000 psi gauge attached. Gauge had a reading of zero psi at time of inspection. Well had had a digital pressure gauge attached above the swab valve that read 1248 PSI.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2643973 798524 2017-10-04 OGA3211(H) Administrative

For data sources see[8]