If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
| Well ID: 37-081-21016 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.412319,"lon":-77.204689,"icon":""}]} |
| Country: United States | |
| State: Pennsylvania | |
| County: Lycoming | |
| Municipality: Cogan House Township | |
| Operator Name: ARD OPR LLC | |
| Well Pad ID: 148464 | |
| Farm/Lease Name: H LYLE LANDON A 5H | |
| License Status: | |
| Spud Date: | |
| Permit Date: 2012-08-24 | |
| Well Type: GAS | |
| Unconventional Well: Y | |
| Configuration: Horizontal Well | |
| Conservation: No | |
| Latitude: 41.412319 | |
| Longitude: -77.204689 |
| Date | Event |
|---|---|
| 2012-08-24 | New Permit Application |
| 2012-09-15 | Performed Spud Operation |
| 2013-02-27 | Drilling Completion |
| 2013-06-06 | Perforation |
| 2014-03-05 | DEVIATED |
For data sources see[4]
| Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
|---|---|---|---|---|---|
| 1 | 2013-06-20 | 2013-06-29 | 7,376 | 3,554,540 | 0 |
| Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
|---|---|---|---|---|---|---|---|---|
| 1 | FEAC-20 | Trican Well Service | Iron Control | Acetic Acid | 64-19-7 | 50 | 0.00285374 | 1024.1 |
| Citric Acid | 77-92-9 | 30 | 0.00171224 | 614.459 | ||||
| AI-7NR | Trican Well Service | Corrosion Inhibitor | Prop-2-yn-1-ol | 107-19-7 | 1 | 0.00002418 | 8.679 | |
| Water | Anadarko | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 82.6574 | 29,662,600.0 | |
| Bio-Clear 5000 | Trican Well Service | Biocide | 2,2-dibromo-3-nitrilopropionamide | 10222-01-2 | 10 | 0.00238866 | 857.198 | |
| Polyethylene glycol | 25322-68-3 | 70 | 0.0167206 | 6000.39 | ||||
| Sand (Proppant) | Trican Well Service | Proppant | Hexamethylenetretramine | 100-97-0 | 1 | 0.166287 | 59674 | |
| Quartz | 14808-60-7 | 99 | 16.4624 | 5,907,730.0 | ||||
| FR-15 | Trican Well Service | Friction Reducer | Paraffinic, Naphthenic Solvent | 64742-47-8 | 25 | 0.013249 | 4754.56 | |
| Proprietary Amide | Proprietary | 2.5 | 0.0013249 | 475.456 | ||||
| Hydrochloric Acid (7.5%) | Trican Well Service | Acidizing | Hydrochloric Acid | 7647-01-0 | 7.5 | 0.0471592 | 16923.7 | |
| Bio-Clear 1000 | Trican Well Service | Biocide | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 98 | 0.000106503 | 38.22 |
For data sources see[5]
| Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
|---|---|---|---|---|---|---|---|
| 2012 | ANADARKO E&P ONSHORE LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
| 2013 | ANADARKO E&P ONSHORE LLC | 219,827.00 | 102 | 0.00 | 0 | 0.00 | 0 |
| 2014 | ANADARKO E&P ONSHORE LLC | 390,386.00 | 365 | 0.00 | 0 | 0.00 | 0 |
| 2015 | ANADARKO E&P ONSHORE LLC | 139,296.00 | 218 | 0.00 | 0 | 0.00 | 0 |
| 2016 | ANADARKO E&P ONSHORE LLC | 209,161.00 | 361 | 0.00 | 0 | 0.00 | 0 |
| 2017 | ARD OPR LLC | 131,044.16 | 341 | 0.00 | 0 | 0.00 | 0 |
| 2018 | ARD OPR LLC | 88,772.45 | 317 | 0.00 | 0 | 0.00 | 0 |
| 2019 | ARD OPR LLC | 104,698.33 | 359 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
| Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
|---|---|---|---|---|---|
| 2012 | ANADARKO E&P ONSHORE LLC | Drill Cuttings | 569.88 Tons | LANDFILL | 301626 |
| 2013 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 19,459.48 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2014 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 15,016.88 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2015 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 678.52 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
| 2015 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 48.40 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
| 2015 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 2,384.57 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2016 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 305.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW005 |
| 2016 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 687.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
| 2016 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 192.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2016 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 1,274.01 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
| 2016 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 20.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
| 2016 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 298.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
| 2016 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 2,435.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
| 2017 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 465.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
| 2017 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 1,745.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
| 2017 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 53.00 Bbl | INJECTION DISPOSAL WELL | 34-031-27177 |
| 2017 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 20.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
| 2017 | ARD OPR LLC | Produced Fluid | 211.31 Bbl | REUSE (AT WELL PAD) | |
| 2017 | ANADARKO E&P ONSHORE LLC | Produced Fluid | 441.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
| 2018 | ARD OPR LLC | Produced Fluid | 463.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
| 2018 | ARD OPR LLC | Produced Fluid | 1,240.79 Bbl | REUSE (AT WELL PAD) | |
| 2019 | ARD OPR LLC | Produced Fluid | 140.59 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
| 2019 | ARD OPR LLC | Produced Fluid | 2,709.26 Bbl | REUSE (AT WELL PAD) | |
| 2019 | ARD OPR LLC | Servicing Fluid | 40.60 Bbl | REUSE (AT WELL PAD) | |
| 2019 | ARD OPR LLC | Produced Fluid | 68.83 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
For data sources see[7]
| Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|---|
| 2101646 | Primary Facility | 2012-09-19 | Drilling/Alteration | No Violations Noted | |
| 2124931 | Primary Facility | 2012-12-19 | Drilling/Alteration | No Violations Noted | |
| 2181528 | Primary Facility | 2013-07-08 | Routine/Complete Inspection | No Violations Noted | |
| 2325608 | Primary Facility | 2014-11-25 | Incident- Response to Accident or Event | No Violations Noted | On 11/22/2014 Mark Barbier (Anadarko) reported approximately 20 barrels of produced fluid and associated production gas was discharged (uncontrolled to the atmosphere) from the 4H well due to a pipe joint failure on the wellhead. According to the call, the well was shut in manually by Anadarko personnel. |
| 2521469 | Primary Facility | 2016-09-15 | Routine/Complete Inspection | No Violations Noted | Routine Inspection; 9/15/2016.
I entered the location at 13:40 and began the inspection. At the time of the inspection, five producing wells (081-21014, 081-20562, 081-21015, 081-20563, and 081-21016) and one plugged well were located onsite. The well site was in good condition and no E&S issues were observed. The site has no active well permits that have not been drilled. ESX10-081-0041 previously expired and ESG29-081-16-0003 is currently active. The wells onsite were drilled from 2011 to 2012 and the well site has not been restored. Anadarko’s most recent restoration timeline submission indicates PCSM will be permitted in 2016 (as noted above) and installed in 2017. The Department considers a well site to be restored under Section 3216(c) of the 2012 Oil and Gas Act when the oil or gas owners or operators meet the following: 1. All permanent post construction stormwater control features as the Post Construction Stormwater Management/Site Restoration Plan are in place. 2. Remaining impervious are |
| 2575465 | Primary Facility | 2017-03-21 | Routine/Complete Inspection | No Violations Noted | Routine inspection of unvonventional well pad in production. A-5H well is in production with no detectable methane emissions. Bubbling noted on location, later discovered to be a phenomenon of the thawing ground. Methane emissions not detected by GES during sampling of location. |
| 2578524 | Primary Facility | 2017-03-23 | Routine/Complete Inspection | No Violations Noted | Routine inspection of unconventional well in production. No violations noted at time of inspection. |
| 2581694 | Primary Facility | 2017-03-28 | Follow-up Inspection | No Violations Noted | Follow up inspection of an unconventional well pad in production. Some bubbling still noted on the pad. 0% combustible gas emissions detected at time of inspection. No violations noted at time of inspection. |
| 2584332 | Primary Facility | 2017-04-12 | Follow-up Inspection | No Violations Noted | Follow up inspection of location and wells following discovery of a bubbling phenomenon on location. Phenomenon appears to have subsided, No methane detected during inspection. No violations noted at time of inspection. |
| 2590155 | Primary Facility | 2017-05-03 | Routine/Complete Inspection | No Violations Noted | Routine inspection of unconvnetional well in porduction. No violations noted at time of inspection. |
| 2592432 | Primary Facility | 2017-05-03 | Routine/Complete Inspection | No Violations Noted | Inspection of 11 3/4" x 8 5/8" annulus vent on well. 0% methane detected at time of inspection. Well tag missing, being replaced. No violations noted at time of inspection. |
| 2643973 | Primary Facility | 2017-10-04 | Routine/Complete Inspection | Violation(s) Noted | Weather was 57° and sunny at time of inspection. 5 1/2 x 9 5/8 annulus is plumbed to the surface and has a digital gauge attached. Gauge read 9 PSI at time of inspection. The second annular event is plumbed to the surface with an analog 0 to 1000 psi gauge attached. Gauge had a reading of zero psi at time of inspection. Well had had a digital pressure gauge attached above the swab valve that read 1248 PSI. |
| Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
|---|---|---|---|---|---|---|
| 2643973 | 798524 | 2017-10-04 | OGA3211(H) | Administrative |
For data sources see[8]