If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-081-21280 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.346458,"lon":-76.958692,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Lycoming | |
Municipality: Gamble Township | |
Operator Name: INFLECTION ENERGY (PA) LLC | |
Well Pad ID: 149762 | |
Farm/Lease Name: STUNNER SMITH 4H | |
License Status: | |
Spud Date: | |
Permit Date: 2013-08-08 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.346458 | |
Longitude: -76.958692 |
Date | Event |
---|---|
Newly Drilled | |
2013-08-08 | New Permit Application |
2017-05-18 | Begin Plugging |
2017-05-18 | Finished Plugging |
2018-03-12 | New Permit Application |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2013 | INFLECTION ENERGY LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | INFLECTION ENERGY (PA) LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | INFLECTION ENERGY (PA) LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | INFLECTION ENERGY (PA) LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | INFLECTION ENERGY (PA) LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2013 | INFLECTION ENERGY LLC | Drill Cuttings | 286.65 Tons | LANDFILL | 301626 |
2014 | INFLECTION ENERGY LLC | Drill Cuttings | 286.65 Tons | LANDFILL | SWF-1021 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2209515 | Primary Facility | 2013-10-02 | Routine/Complete Inspection | No Violations Noted | |
2246459 | Primary Facility | 2014-02-19 | Routine/Complete Inspection | No Violations Noted | |
2247498 | Primary Facility | 2014-02-20 | Drilling/Alteration | No Violations Noted | |
2254934 | Primary Facility | 2014-03-18 | Routine/Partial Inspection | No Violations Noted | |
2261498 | Primary Facility | 2014-04-02 | Routine/Partial Inspection | No Violations Noted | H&P 354 onsite drilling the 081-21286 well, modular tank onsite storing flowback. No Vio. |
2299100 | Primary Facility | 2014-08-27 | Routine/Complete Inspection | No Violations Noted | |
2435552 | Primary Facility | 2015-12-17 | Routine/Complete Inspection | No Violations Noted | I arrived onsite at 09:16 for a routine inspection and found 6 wells on the pad with two in production. |
2461962 | Primary Facility | 2016-03-01 | Routine/Complete Inspection | No Violations Noted | conductor |
2554201 | Primary Facility | 2017-01-12 | Routine/Complete Inspection | No Violations Noted | Stunner Smith 4H, (SS 4H), 081-21280: conductor, cellar filled with gravel. |
2570901 | Primary Facility | 2017-03-13 | Administrative/File Review | Violation(s) Noted | Administrative Inspection Record created for the purpose of entering Enforcement Record for failure to plug an abandoned well.
Well was plugged and the Plugging Certificate was reviewed and approved. VIOL resolved as CRCTD on the date the PLUGC was approved (7/5/2017). ~CMB~ |
2597324 | Primary Facility | 2017-05-24 | Routine/Complete Inspection | No Violations Noted | Routine Inspection of (3) conductors on Inflection’s Smith pad; the #5 (081-21281), #6 (081-21282), and #4 (081-21280). Notice of Intent to plug the conductors was recently received. All (3) conductors were capped and visible ground level time of inspection. No major issues at this time were noted. |
2610467 | Primary Facility | 2017-07-05 | Administrative/File Review | No Violations Noted | July 5th 2017: Certificate of Well Plugging for this conductor has been received, reviewed, signed, and sent to file. |
2686994 | Primary Facility | 2018-01-23 | Routine/Complete Inspection | No Violations Noted | Arrived at 13:15. Weather: warm, sunny, T¿s in upper 40s. There are 7 wells. The Stunner Smith 1H and Ryder Park 1H are in production. Stunner Smith 2H and 3H are top-holed. SS 2H: TD 6692¿ with a plug from 6648¿ to 6144. IC casing to 3018¿. SS 3H: TD 6621¿, IC casing to 3007. For both wells, methane was leaking (few bubbles, slow rate) from the join between the intermediate vent pipe and the intermediate casing (Altair 5X gas meter calibrated on 1/1/23/17). Notified Greg Malekos of the leaks. For the SS 6H, a plugged conductor, all that was visible was a gravel filled cellar. For the SS 4H and SS 5H, also plugged, the cellars were filled with water. The surface hole locations for the plugged conductors were updated in eFACTS to address locational discrepancies observed in the field. |
2696677 | Primary Facility | 2018-02-22 | Follow-up Inspection | No Violations Noted | Arrived at 7:40. Weather: rainy, temperatures in low 40's. There are 7 wells. The Stunner Smith 1H and Ryder Park 1H are in production. Stunner Smith 2H and 3H are top-holed. SS 2H: TD 6692' with a plug from 6648' to 6144'. IC casing to 3018'. SS 3H: TD 6621', IC casing to 3007. This is a follow up IR to see if methane is still leaking from the join between the intermediate vent pipe and the intermediate casing. It was. Will schedule follow-up with Inflection. For the SS 6H, a plugged conductor, all that was visible was a gravel filled cellar. For the SS 4H and SS 5H, also plugged, the cellars were filled with water. |
2818956 | Primary Facility | 2018-12-26 | Routine/Complete Inspection | No Violations Noted | A H&P rig is drilling on the Smith Well pad. The Department representative did not locate the rig manager so Department could not determine which well was being drilled.
The site had a primary containment overlaid with wood plank rig matting with beveled edges (see photo). All materials held on containment and within secondary containment. The overall site conditions were clean and well organized. No leaks or spills detected. No violations. |
2840554 | Primary Facility | 2019-02-14 | Routine/Complete Inspection | No Violations Noted | I met Ross Drnjevich of Inflection on the site. H&P 521 on location, drilling the 2HN well at 8300'. The chemical containment appeared to be in good condition, but also contained several inches of snow and ice. The secondary containment for the mud tanks had been bolted on with wood strips on the inside of the containment in the back, approximately 4-5" down from the top. Although it is unlikely that this brought the containment volume below 110% of the volume of the tanks, I still recommended to Ross that these liners be attached on the outside of the berms. Meltwater had built up to 3-4" deep on the backside of the pad, and Ross told me he would have it vacced. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2570901 | 780480 | 2017-03-13 | 2017-07-05 | 78a91(a) | Environmental Health & Safety | The Stunner Smith 4H well was spud August 20, 2013 and was drilled to a depth necessary to set conductor casing under the authorization of well permit number 081-21280. The well permit for 081-21280 expired August 8, 2014. The well remains a conductor and has had no drilling activity since 2013. |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
780480 | 351608 | NOV - Notice of Violation | 2017-07-05 |
For data sources see[7]