Well ID: 37-081-21282
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Gamble Township
Operator Name: INFLECTION ENERGY (PA) LLC
Well Pad ID: 149762
Farm/Lease Name: STUNNER SMITH 6H
License Status: Plugged and Abandoned
Spud Date:
Permit Date: 2013-08-08
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.346469
Longitude: -76.958639

For data sources see[1][2][3]

Well History

Date Event
Newly Drilled
2013-08-08 New Permit Application
2017-05-18 Begin Plugging
2017-05-18 Finished Plugging
2018-03-05 New Permit Application
2018-08-31 MOD
2018-11-10 Performed Spud Operation
2019-01-25 MOD

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 INFLECTION ENERGY LLC 0.00 0 0.00 0 0.00 0
2014 INFLECTION ENERGY (PA) LLC 0.00 0 0.00 0 0.00 0
2015 INFLECTION ENERGY (PA) LLC 0.00 0 0.00 0 0.00 0
2016 INFLECTION ENERGY (PA) LLC 0.00 0 0.00 0 0.00 0
2017 INFLECTION ENERGY (PA) LLC 0.00 0 0.00 0 0.00 0
2019 INFLECTION ENERGY (PA) LLC 698,807.26 70 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 INFLECTION ENERGY LLC Drill Cuttings 286.65 Tons LANDFILL 301626
2014 INFLECTION ENERGY LLC Drill Cuttings 286.65 Tons LANDFILL 301626
2018 INFLECTION ENERGY (PA) LLC Synthetic Liner Materials 0.38 Tons LANDFILL 100955
2018 INFLECTION ENERGY (PA) LLC Drill Cuttings 339.44 Tons LANDFILL 100955
2018 INFLECTION ENERGY (PA) LLC Other Oil & Gas Wastes 140.00 Bbl REUSE (AT WELL PAD)
2019 INFLECTION ENERGY (PA) LLC Produced Fluid 3,604.64 Bbl RESIDUAL WASTE TRANSFER FACILITY WMGR123NC039
2019 INFLECTION ENERGY (PA) LLC Synthetic Liner Materials 16.46 Tons LANDFILL 100955
2019 INFLECTION ENERGY (PA) LLC Produced Fluid 796.25 Bbl REUSE (AT WELL PAD)
2019 INFLECTION ENERGY (PA) LLC Other Oil & Gas Wastes 100.00 Bbl REUSE (AT WELL PAD)
2019 INFLECTION ENERGY (PA) LLC Soil Contaminated by Oil & Gas Related Spills 37.03 Tons LANDFILL 100955
2019 INFLECTION ENERGY (PA) LLC Produced Fluid 8,854.46 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119
2019 INFLECTION ENERGY (PA) LLC Drilling Fluid Waste 4,357.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 INFLECTION ENERGY (PA) LLC Produced Fluid 4.68 Tons LANDFILL 100955
2019 INFLECTION ENERGY (PA) LLC Drilling Fluid Waste 1,770.83 Bbl REUSE (AT WELL PAD)
2019 INFLECTION ENERGY (PA) LLC Drill Cuttings 1,105.20 Tons LANDFILL 100955
2019 INFLECTION ENERGY (PA) LLC Produced Fluid 35.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 INFLECTION ENERGY (PA) LLC Soil Contaminated by Oil 37.03 Tons LANDFILL 100955
2019 INFLECTION ENERGY (PA) LLC Filter Socks 0.02 Tons LANDFILL 301626

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2209517 Primary Facility 2013-10-02 Routine/Complete Inspection No Violations Noted
2246462 Primary Facility 2014-02-19 Routine/Complete Inspection No Violations Noted
2247500 Primary Facility 2014-02-20 Drilling/Alteration No Violations Noted
2254937 Primary Facility 2014-03-18 Routine/Partial Inspection No Violations Noted
2261500 Primary Facility 2014-04-02 Routine/Partial Inspection No Violations Noted H&P 354 onsite drilling the 081-21286 well, modular tank onsite storing flowback. No Vio.
2299103 Primary Facility 2014-08-27 Routine/Complete Inspection No Violations Noted
2435557 Primary Facility 2015-12-17 Routine/Complete Inspection No Violations Noted I arrived onsite at 09:16 for a routine inspection and found 6 wells on the pad with two in production.
2461965 Primary Facility 2016-03-01 Routine/Complete Inspection No Violations Noted conductor
2554212 Primary Facility 2017-01-12 Routine/Complete Inspection No Violations Noted Conductor only
2570903 Primary Facility 2017-03-13 Administrative/File Review Violation(s) Noted Administrative Inspection Record created for the purpose of entering Enforcement Record for failure to plug an abandoned well.

Well was plugged and the Plugging Certificate was reviewed and approved. VIOL resolved as CRCTD on the date the PLUGC was approved (7/5/2017). ~CMB~

2597322 Primary Facility 2017-05-24 Routine/Complete Inspection No Violations Noted Routine Inspection of (3) conductors on Inflection’s Smith pad; the #5 (081-21281), #6 (081-21282), and #4 (081-21280). Notice of Intent to plug the conductors was recently received. All (3) conductors were capped and visible ground level time of inspection. No major issues at this time were noted.
2610470 Primary Facility 2017-07-05 Administrative/File Review No Violations Noted July 5th 2017: Certificate of Well Plugging for this conductor has been received, reviewed, signed, and sent to file.
2686996 Primary Facility 2018-01-23 Routine/Complete Inspection No Violations Noted Arrived at 13:15. Weather: warm, sunny, T¿s in upper 40s. There are 7 wells. The Stunner Smith 1H and Ryder Park 1H are in production. Stunner Smith 2H and 3H are top-holed. SS 2H: TD 6692¿ with a plug from 6648¿ to 6144. IC casing to 3018¿. SS 3H: TD 6621¿, IC casing to 3007. For both wells, methane was leaking (few bubbles, slow rate) from the join between the intermediate vent pipe and the intermediate casing (Altair 5X gas meter calibrated on 1/1/23/17). Notified Greg Malekos of the leaks. For the SS 6H, a plugged conductor, all that was visible was a gravel filled cellar. For the SS 4H and SS 5H, also plugged, the cellars were filled with water. The surface hole locations for the plugged conductors were updated in eFACTS to address locational discrepancies observed in the field.
2696679 Primary Facility 2018-02-22 Follow-up Inspection No Violations Noted Arrived at 7:40. Weather: rainy, temperatures in low 40's. There are 7 wells. The Stunner Smith 1H and Ryder Park 1H are in production. Stunner Smith 2H and 3H are top-holed. SS 2H: TD 6692' with a plug from 6648' to 6144'. IC casing to 3018'. SS 3H: TD 6621', IC casing to 3007. This is a follow up IR to see if methane is still leaking from the join between the intermediate vent pipe and the intermediate casing. It was. Will schedule follow-up with Inflection. For the SS 6H, a plugged conductor, all that was visible was a gravel filled cellar. For the SS 4H and SS 5H, also plugged, the cellars were filled with water.
2817888 Primary Facility 2018-12-17 Routine/Complete Inspection No Violations Noted Weather was 30° and cloudy at time of inspection. Met with Inflection representative Ross Drnjevich on location. This well had is surface casing hole drilled and the casing was hanging uncemented. Rig intended to cement the 10H and 6H casing at the same time once the rig skids over to the 3H. Conducted a walk around inspection of location. No violations were noted at time of inspection.
2818952 Primary Facility 2018-12-26 Routine/Complete Inspection No Violations Noted A H&P rig is drilling on the Smith Well pad. The Department representative did not locate the rig manager so Department could not determine which well was being drilled.

The site had a primary containment overlaid with wood plank rig matting with beveled edges (see photo). All materials held on containment and within secondary containment. The overall site conditions were clean and well organized. No leaks or spills detected. No violations.

2821522 Primary Facility 2018-12-20 Routine/Complete Inspection No Violations Noted Weather was 30° and cloudy at time of inspection. Met with Inflection representatives Ross Drjnevitch and Greg Malekos on location. Well surface casing was cemented on 12/19/18. Reviewed the cement job logs and no discrepancies were noted. Discussed the cement jobs with the Inflection representatives and no discrepancies were noted. Well was closed in with a night cap and the rig skidded onto drill surface casing for other wells on the pad. No violations noted at time of inspection.
2822728 Primary Facility 2019-01-03 Routine/Complete Inspection No Violations Noted Weather was 38° and cloudy at time of inspection. Met with Inflection representatives Jamie Czerneski and Greg Malekos on location. Halliburton was on location ready to cement the 13 3/8 intermediate casing for this well. Stayed for the duration of the cement job and everything went according to plan. Good cement returns to surface and nearly perfectly calculated returns based on a true hole. No violations noted at time of inspection.
2827933 Primary Facility 2019-01-15 Routine/Complete Inspection No Violations Noted Weather was 25° and sunny at time of inspection. Met with Inflection representatives Ross Drjnevitch and Greg Malekos on location. Well recently had the first intermediate string of 13 3/8" casing drilled and cemented. Well was closed in at time of inspection with a nightcap. Water in the cellar was frozen solid at time of inspection. No violations were noted at time of inspection.
2835445 Primary Facility 2019-02-05 Routine/Complete Inspection No Violations Noted Weather was 37° and sunny at time of inspection. Met with Inflection representative Greg Malekos on location. Rig was currently drilling the 12 1/4" hole for the (9 5/8")second intermediate string of casing. They were expecting to TD at 8365' and then begin to load the hole with water and run casing. They were estimating running cement in the early morning tomorrow. No violations were noted at time of inspection.
2840035 Primary Facility 2019-02-11 Routine/Complete Inspection No Violations Noted Weather was 30° and cloudy at time of inspection. Met with Inflection representative Jamie Czerneski on location. Well was shut in at time of inspection. The second intermediate casing (9 5/8") was just cemented. Reviewed the cement job log and no discrepancies were noted at time of inspection. Surface conditions do not appear to have changed from the previous inspection. No violations were noted at time of inspection.
2842025 Primary Facility 2019-02-20 Routine/Complete Inspection No Violations Noted Weather- 21 degrees and cloudy at time of inspection

Met with Inflection representative Ross Drjnevitch and Greg Malekos on location. Well was closed in with a nightcap at time of inspection. Wells on pad are being batch drilled. No violations noted at time of inspection.

2844692 Primary Facility 2019-02-26 Routine/Complete Inspection No Violations Noted Weather was 24 degrees and sunny at time of inspection. Met with Inflection representative Ross Drjnevitch on location. This well was shut in with a night cap. wellhead had bubbling, Inflection will pump cellar out and evaluate cellar condition. The bubbling does not appear to be coming from an annular space. This well will be completed at a later date. No violations at time of inspection.
2845094 Primary Facility 2019-02-27 Routine/Complete Inspection No Violations Noted Weather was 22 degrees and snowing at time of inspection. Met with Inflection representative Jamie Czerneski on location. This well was shut in with a night cap. Following up from previous days inspection. Cellar was full of water and wellhead appeared to be bubbling. Cellar was pumped and it was determined that the tubing port on the wellhead had a bad seal and was causing the leak. The seal was fixed. No violation noted at time of inspection.
2849864 Primary Facility 2019-03-07 Routine/Complete Inspection No Violations Noted Weather was 12 degrees and sunny. Met with Inflection representative Jamie Czerneski and Greg Malekos on location. Well is closed in with a nightcap at time on inspection. Well had 3 string of casing drilled and cemented at time of inspection. This well will be completed at a later date. No violation noted at time of inspection.
2852794 Primary Facility 2019-03-13 Routine/Complete Inspection No Violations Noted Weather was 30 degrees and sunny. Met with Inflection representative Ross Drnjevich on location. Well is closed in with a nightcap at time on inspection. Well had 3 string of casing drilled and cemented at time of inspection. This well will be completed at a later date. No violation noted at time of inspection.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2570903 780482 2017-03-13 2017-07-05 78a91(a) Environmental Health & Safety The Stunner Smith 6H well was spud August 21, 2013 and was drilled to a depth necessary to set conductor casing under the authorization of well permit number 081-21282. The well permit for 081-21282 expired August 8, 2014. The well remains a conductor and has had no drilling activity since 2013.

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
780482 351608 NOV - Notice of Violation 2017-07-05