X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-081-21286

Well Details

Well ID: 37-081-21286
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Gamble Township
Operator Name: INFLECTION ENERGY (PA) LLC
Well Pad ID: 149762
Farm/Lease Name: RIDER PARK SMITH 1H
License Status:
Spud Date:
Permit Date: 2013-08-29
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.346439
Longitude: -76.958739

For data sources see[1][2][3]

Well History

Date Event
2013-08-22 Performed Spud Operation
2013-08-29 New Permit Application
2017-12-15 MOD

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-08-13 2014-08-18 9,345 7,518,670 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 K-BAC 1020 U.S. Well Services Anti-Bacterial Agent 2,2-dibromo-3-nitrilopropionamide 10222-01-2 20 0.00788 6034.28
Polyethylene Glycol 25322-68-3 50 0.009 6893.51
Water 7732-18-5 20 0.00322 2461.97
AI-301 U.S. Well Services Acid Corrosion Inhibitors Coco amine 61791-14-8 5 0.00002000 14.5783
Hydrogen Chloride 7647-01-0 10 0.00005000 36.7627
Methenamine 100-97-0 20 0.00011 84.3007
Polyethylene polyamine 68603-67-8 10 0.00004000 31.9138
Diethylene Glycol 111-46-6 30 0.00014 106.39
LGC-15 U.S. Well Services Gelling Agents Petroleum Distillates 64742-47-8 60 0.00092 704.938
Guar Gum 9000-30-0 50 0.00011 87.5
Surfactant 68439-51-0 3 0.00006000 44.6607
Suspending agent (solid) 14808-60-7 3 0.00001000 5.25
WFRA-405 U.S. Well Services Friction Reducer Water 7732-18-5 40 0.02885 22087.7
Anionic Polyacrylamide 62649-23-4 40 0.02885 22087.7
Petroleum Distillates 64742-47-8 22 0.01277 9779.31
Ethoxylate Alcohol 68551-12-2 5 0.00361 2760.96
Ammonium Chloride 12125-02-9 5 0.00361 2760.96
HCL Acid (12.6%-17.5%) U.S. Well Services, LLC Bulk Acid Water 7732-18-5 87.4 0.09045 69256.9
Hydrogen Chloride 7647-01-0 17.5 0.03762 28808
SI-1100 U.S. Well Services Scale Inhibitor Di Water 7732-18-5 80 0.01612 12343.2
Acrylic polymer 52255-49-9 5 0.00101 771.45
hexamethylenediamine tetra (methylene phosphonic acid) 38820-59-6 10 0.00252 1928.63
2-Phosphonobutane 1,2,4 tricarboxylic salt 37971-36-1 10 0.0026 1990.34
bis (hexamethylene) tramine penta
(methylene phosphonic acid) - phosphate acid
40623-75-4 10 0.00232 1774.34
Copolymer of Maleic and Acrylic acid 26677-99-6 10 0.00238 1820.62
Ethylene Glycol 107-21-1 40 0.00911 6973.91
Potassium salt of diethylene triamine
penta (methylene phosphonic acid)
15827-60-8 10 0.00272 2082.92
30/50 EconoProp U.S. Well Services Ceramic Proppant Silicon Dioxide 7631-86-9 35 0.37911 290269
Silica Crystalline-Cristobalite 14464-46-1 20 1.80672 1,383,340.0
Mullite 1302-93-8 85 7.67854 5,879,190.0
Sand U.S. Well Services, LLC Proppant Crystalline Silica, quartz 14808-60-7 100 8.05433 6,166,920.0
Water Inflection Energy Base Fluid Water 7732-18-5 100 81.8152 62,643,000.0
AP One U.S. Well Services Gel Breakers Ammonium Persulfate 7727-54-0 100 0.00002000 15

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 INFLECTION ENERGY LLC 0.00 0 0.00 0 0.00 0
2014 INFLECTION ENERGY (PA) LLC 1,120,871.00 112 0.00 0 0.00 0
2015 INFLECTION ENERGY (PA) LLC 2,834,598.84 363 0.00 0 0.00 0
2016 INFLECTION ENERGY (PA) LLC 2,364,071.22 366 0.00 0 0.00 0
2017 INFLECTION ENERGY (PA) LLC 1,672,914.00 364 0.00 0 0.00 0
2018 INFLECTION ENERGY (PA) LLC 1,301,686.00 364 0.00 0 0.00 0
2019 INFLECTION ENERGY (PA) LLC 565,755.79 237 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 INFLECTION ENERGY LLC Drill Cuttings 286.65 Tons LANDFILL 301626
2014 INFLECTION ENERGY (PA) LLC Produced Fluid 1,882.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2014 INFLECTION ENERGY LLC Drill Cuttings 286.65 Tons LANDFILL 301626
2014 INFLECTION ENERGY (PA) LLC Produced Fluid 3,239.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 INFLECTION ENERGY (PA) LLC Produced Fluid 25,166.50 Bbl REUSE OTHER THAN ROAD SPREADING
2016 INFLECTION ENERGY (PA) LLC Produced Fluid 4,433.50 Bbl REUSE OTHER THAN ROAD SPREADING
2016 INFLECTION ENERGY (PA) LLC Waste Water Treatment Sludge 64.78 Tons LANDFILL 301626
2017 INFLECTION ENERGY (PA) LLC Produced Fluid 116.72 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 INFLECTION ENERGY (PA) LLC Produced Fluid 219.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017 INFLECTION ENERGY (PA) LLC Produced Fluid 594.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 INFLECTION ENERGY (PA) LLC Produced Fluid 282.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119
2017 INFLECTION ENERGY (PA) LLC Produced Fluid 528.00 Bbl REUSE (AT WELL PAD)
2018 INFLECTION ENERGY (PA) LLC Produced Fluid 920.00 Bbl REUSE (AT WELL PAD)
2018 INFLECTION ENERGY (PA) LLC Other Oil & Gas Wastes 1,150.00 Bbl REUSE (AT WELL PAD)
2018 INFLECTION ENERGY (PA) LLC Produced Fluid 530.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119
2018 INFLECTION ENERGY (PA) LLC Other Oil & Gas Wastes 60.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 INFLECTION ENERGY (PA) LLC Produced Fluid 8,854.46 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119
2019 INFLECTION ENERGY (PA) LLC Drilling Fluid Waste 85.00 Bbl REUSE (AT WELL PAD)
2019 INFLECTION ENERGY (PA) LLC Synthetic Liner Materials 3.70 Tons LANDFILL 100955
2019 INFLECTION ENERGY (PA) LLC Produced Fluid 3,604.64 Bbl RESIDUAL WASTE TRANSFER FACILITY WMGR123NC039
2019 INFLECTION ENERGY (PA) LLC Other Oil & Gas Wastes 215.00 Bbl REUSE (AT WELL PAD)
2019 INFLECTION ENERGY (PA) LLC Produced Fluid 916.25 Bbl REUSE (AT WELL PAD)
2019 INFLECTION ENERGY (PA) LLC Filter Socks 0.02 Tons LANDFILL 301626
2019 INFLECTION ENERGY (PA) LLC Drill Cuttings 22.60 Tons LANDFILL 100955
2019 INFLECTION ENERGY (PA) LLC Produced Fluid 35.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 INFLECTION ENERGY (PA) LLC Produced Fluid 0.64 Tons LANDFILL 100955

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2209059 Primary Facility 2013-10-01 Drilling/Alteration No Violations Noted
2209518 Primary Facility 2013-10-02 Routine/Complete Inspection No Violations Noted
2246464 Primary Facility 2014-02-19 Routine/Complete Inspection No Violations Noted
2247502 Primary Facility 2014-02-20 Drilling/Alteration No Violations Noted
2254939 Primary Facility 2014-03-18 Routine/Partial Inspection No Violations Noted
2261502 Primary Facility 2014-04-02 Routine/Partial Inspection No Violations Noted H&P 354 onsite drilling the 081-21286 well, modular tank onsite storing flowback. No Vio.
2299105 Primary Facility 2014-08-27 Routine/Complete Inspection No Violations Noted
2435562 Primary Facility 2015-12-17 Routine/Complete Inspection No Violations Noted I arrived onsite at 09:16 for a routine inspection and found 6 wells on the pad with two in production.
2461960 Primary Facility 2016-03-01 Routine/Complete Inspection No Violations Noted 7 wells spudded on site and a large above-ground water tank. There was a hose in place between the water tank and the produced water tanks on site. This well was in production. 9-5/8" x 5-1/2" 11% methane. Methane not detected on other annuli. Note that there are a number of permiting and reporting discrepencies assoicated with the wells on this location.
2554199 Primary Facility 2017-01-12 Routine/Complete Inspection No Violations Noted Rider Park Smith 1H (RPS 1H), 081-21286: well in production. Three annular vents. 20” x 13-3/8”: 0% methane

13-3/8” x 9-5/8”: 0% methane 9-58” x 5-1/2”: 11% methane.

2605760 Primary Facility 2017-06-20 Administrative/File Review Violation(s) Noted Administrative Inspection entered for the purpose of entering an Enforcement Record (NOV).

VIOLS closed (CRCTD) 12/15/2017 upon issuance of permit modification.

2686992 Primary Facility 2018-01-23 Routine/Complete Inspection No Violations Noted Arrived at 13:15. Weather: warm, sunny, T¿s in upper 40s. There are 7 wells. The Stunner Smith 1H and Ryder Park 1H are in production. Stunner Smith 2H and 3H are top-holed. SS 2H: TD 6692¿ with a plug from 6648¿ to 6144. IC casing to 3018¿. SS 3H: TD 6621¿, IC casing to 3007. For both wells, methane was leaking (few bubbles, slow rate) from the join between the intermediate vent pipe and the intermediate casing (Altair 5X gas meter calibrated on 1/1/23/17). Notified Greg Malekos of the leaks. For the SS 6H, a plugged conductor, all that was visible was a gravel filled cellar. For the SS 4H and SS 5H, also plugged, the cellars were filled with water. The surface hole locations for the plugged conductors were updated in eFACTS to address locational discrepancies observed in the field.
2818950 Primary Facility 2018-12-26 Routine/Complete Inspection No Violations Noted A H&P rig is drilling on the Smith Well pad. The Department representative did not locate the rig manager so Department could not determine which well was being drilled.

The site had a primary containment overlaid with wood plank rig matting with beveled edges (see photo). All materials held on containment and within secondary containment. The overall site conditions were clean and well organized. No leaks or spills detected. No violations.

2822724 Primary Facility 2019-01-03 Routine/Complete Inspection No Violations Noted Weather was 38° and cloudy at time of inspection. Met with Inflection representatives Jamie Czerneski and Greg Malekos on location. Well was covered with a green steel cage at time of inspection. There were 3 annulus vents plumbed to surface at time of inspection. Well was shut in due to 6 new wells being drilled on location. 0% combustible gas was detected anywhere around the well at time of inspection. Well had gas monitoring equipment attached to it for the duration of drilling on the site. No violations were noted at time of inspection.
2827954 Primary Facility 2019-01-15 Routine/Complete Inspection No Violations Noted Weather was 25° and sunny at time of inspection. Met with Inflection representative Ross Drjnevitch and Greg Malekos on location. Well was covered with a green steel cage at time of inspection. There were 3 annulus vents plumbed to surface at time of inspection. Well was shut in due to 6 new wells being drilled on location. 0% combustible gas was detected anywhere around the well at time of inspection. Well had gas monitoring equipment attached to it for the duration of drilling on the site. No violations were noted at time of inspection.
2835437 Primary Facility 2019-02-05 Routine/Complete Inspection No Violations Noted Weather was 37° and sunny at time of inspection. Met with Inflection representative Greg Malekos on location. Well was covered with a green steel cage at time of inspection. There were 3 annulus vents plumbed to surface at time of inspection. Well was shut in due to 6 new wells being drilled on location. 0% combustible gas was detected anywhere around the well at time of inspection. Well had gas monitoring equipment attached to it for the duration of drilling on the location. There did not appear to be any changes in surface conditions of the well since the previous inspection.No violations were noted at time of inspection.
2840021 Primary Facility 2019-02-13 Routine/Complete Inspection No Violations Noted Weather was 30° and cloudy at time of inspection. Met with Inflection representative Jamie Czerneski on location. Well was covered with a green steel cage at time of inspection. There were 3 annulus vents plumbed to surface at time of inspection. Well was shut in due to 6 new wells being drilled on location. 0% combustible gas was detected anywhere around the well at time of inspection. Well had gas monitoring equipment attached to it for the duration of drilling on the location. There did not appear to be any changes in surface conditions of the well since the previous inspection.No violations were noted at time of inspection.
2840556 Primary Facility 2019-02-14 Routine/Complete Inspection No Violations Noted I met Ross Drnjevich of Inflection on the site. H&P 521 on location, drilling the 2HN well at 8300'. The chemical containment appeared to be in good condition, but also contained several inches of snow and ice. The secondary containment for the mud tanks had been bolted on with wood strips on the inside of the containment in the back, approximately 4-5" down from the top. Although it is unlikely that this brought the containment volume below 110% of the volume of the tanks, I still recommended to Ross that these liners be attached on the outside of the berms. Meltwater had built up to 3-4" deep on the backside of the pad, and Ross told me he would have it vacced.
2842027 Primary Facility 2019-02-20 Routine/Complete Inspection No Violations Noted Weather- 21 degrees and cloudy at time of inspection

Met with Inflection representative Ross Drjnevitch and Greg Malekos on location. Well was covered with a green steel cage. Well had 3 annulus vents plumbed to surface. Well was shut in at time of inspection due to 6 new wells being drilled on location. 0% combustible gas was detected anywhere around the well at time of inspection. No violations noted at time of inspection.

2844702 Primary Facility 2019-02-26 Routine/Complete Inspection No Violations Noted Weather was 24 degrees and sunny at time of inspection. Met with Inflection representative Ross Drjnevitch on location. Well was covered with a green steel cage. Well had 3 annulus vents plumbed to surface. Well was shut in at time of inspection due to 6 new wells being drilled on location. 0% combustible gas was detected anywhere around the well at time of inspection. No violations noted at time of inspection.
2849844 Primary Facility 2019-03-07 Routine/Complete Inspection No Violations Noted Weather was 12 degrees and sunny. Met with Inflection representative Jamie Czerneski and Greg Malekos on location. Well was covered with a green steel cage. Well had 3 annulus vents plumbed to surface. Well was shut in at time of inspection due to 6 new wells being drilled on location. 0% combustible gas was detected anywhere around the well at time of inspection. No violations noted at time of inspection.
2852776 Primary Facility 2019-03-13 Routine/Complete Inspection No Violations Noted Weather was 30 degrees and sunny. Met with Inflection representative Ross Drnjevich on location. Well was covered with a green steel cage. Well had 3 annulus vents plumbed to surface. Well was shut in at time of inspection due to 6 new wells being drilled on location. Well had gas monitoring equipment attached tonthe steel cage. 0% combustible gas was detected anywhere around the well at time of inspection. No violations noted at time of inspection.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2605760 788465 2017-06-20 2017-12-15 OGA3211(F1) Administrative Well was intentionally drilled at a Surface Hole Location (SHL) other than the approved SHL on the well permit, resulting in the actual SHL being approximately 149 feet from the permitted SHL.
2605760 788466 2017-06-20 2017-12-15 78a12 Administrative The well was not drilled in accordance with the approved well permit. The actual SHL is approximately 149 feet from the permitted SHL.

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
788465 354434 NOV - Notice of Violation 2017-12-15
788466 354434 NOV - Notice of Violation 2017-12-15

For data sources see[8]

References