If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-083-55194 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.673394,"lon":-78.264622,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: McKean | |
Municipality: Norwich Township | |
Operator Name: PA GEN ENERGY CO LLC | |
Well Pad ID: 149168 | |
Farm/Lease Name: REED RUN NORWICH PAD D 2513 | |
License Status: | |
Spud Date: | |
Permit Date: 2010-10-28 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.673394 | |
Longitude: -78.264622 |
Date | Event |
---|---|
2010-10-28 | New Permit Application |
2011-01-06 | Performed Spud Operation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2017-05-19 | 2017-05-19 | 6,064 | 4,200 | 2 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | 2k7 Water Soluble PAK | OSP | Biocide | Listed Below | ||||
2-Bromo-2-nitropropane-1,3-diol | 52-51-7 | 100 | 0.000595 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | PA GEN ENERGY CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | PA GEN ENERGY CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | PA GEN ENERGY CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | PA GEN ENERGY CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | PA GEN ENERGY CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | PA GEN ENERGY CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | PA GEN ENERGY CO LLC | 13.55 | 1 | 0.00 | 0 | 0.00 | 0 |
2018 | PA GEN ENERGY CO LLC | 27.50 | 1 | 0.00 | 0 | 0.00 | 0 |
2019 | PA GEN ENERGY CO LLC | 41.00 | 30 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | PA GEN ENERGY CO LLC | Produced Fluid | 90.93 Bbl | INJECTION DISPOSAL WELL | 34-007-24355 |
2011 | PA GEN ENERGY CO LLC | Drill Cuttings | 530.25 Tons | ON SITE ENCAPSULATION | |
2011 | PA GEN ENERGY CO LLC | Drilling Fluid Waste | 55.58 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 34-099-23127 |
2011 | PA GEN ENERGY CO LLC | Produced Fluid | 23.43 Bbl | INJECTION DISPOSAL WELL | 34-133-24096 |
2011 | PA GEN ENERGY CO LLC | Produced Fluid | 391.82 Bbl | INJECTION DISPOSAL WELL | UIC 45 |
2011 | PA GEN ENERGY CO LLC | Drill Cuttings | 743.62 Tons | LANDFILL | 100361 |
2011 | PA GEN ENERGY CO LLC | Produced Fluid | 62.74 Bbl | INJECTION DISPOSAL WELL | 34-133-21076 |
2012 | PA GEN ENERGY CO LLC | Produced Fluid | 1,223.63 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | PA GEN ENERGY CO LLC | Produced Fluid | 10.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017 | PA GEN ENERGY CO LLC | Produced Fluid | 320.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2017 | PA GEN ENERGY CO LLC | Synthetic Liner Materials | 0.31 Tons | LANDFILL | 101397 |
2018 | PA GEN ENERGY CO LLC | Other Oil & Gas Wastes | 50.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1988642 | Primary Facility | 2011-04-18 | Drilling/Alteration | No Violations Noted | |
2001164 | Primary Facility | 2011-08-24 | Routine/Complete Inspection | No Violations Noted | |
2032876 | Primary Facility | 2012-01-05 | Routine/Complete Inspection | No Violations Noted | |
2034250 | Primary Facility | 2012-01-04 | Routine/Complete Inspection | No Violations Noted | |
2069969 | Primary Facility | 2012-05-15 | Routine/Complete Inspection | No Violations Noted | |
2121693 | Primary Facility | 2012-12-04 | Routine/Complete Inspection | No Violations Noted | |
2156608 | Primary Facility | 2013-04-10 | Routine/Complete Inspection | No Violations Noted | |
2367647 | Primary Facility | 2015-04-17 | Routine/Complete Inspection | No Violations Noted | |
2486462 | Primary Facility | 2016-05-10 | Routine/Complete Inspection | No Violations Noted | |
2557218 | Primary Facility | 2017-01-31 | Routine/Complete Inspection | No Violations Noted | |
2579695 | Primary Facility | 2017-04-06 | Routine/Complete Inspection | No Violations Noted | There are two producing Marcellus shale wells on this location. No spills or other incidents are noted at this time. The site is stable and vegetated. The operator has the ID sign at the entrance to the location. The main access road to this well has had logging operations on it recently. This has left the road somewhat unstable. |
2755857 | Primary Facility | 2018-07-25 | Routine/Complete Inspection | No Violations Noted | This is a Marcellus shale well pad. The vegetation around most of the site has grown in well and meets vegetative cover requirements of >70%. There are two active wells on site. Signage is in place per regulation. No E/S issues are noted on site. The access road has deteriorated due to recent rains and should be monitored for routine maintenance prior to future projects on this site. |
2794049 | Primary Facility | 2018-10-24 | Routine/Complete Inspection | No Violations Noted | This well had production in June of 2018. They fill a truck up and haul it until a pipeline is available according to PGE employee. There is constant bubbling in the cellar and I could smell sour gas. I notified PGE of the leak and they are going to send someone out to look at it. |
For data sources see[8]