37-085-20189

Well Details

Well ID: 37-085-20189
Loading map...
Country: United States
State: Pennsylvania
County: Mercer
Municipality: Sandy Lake Township
Operator Name: SOUTH SANDY OIL CO
Well Pad ID:
Farm/Lease Name: MCQUISTON 2
License Status: PLUGGED & ABANDONED
Spud Date:
Permit Date: 1979-11-29
Well Type: OIL
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 41.316942
Longitude: -80.033071

For data sources see[1][2][3]

Well History

Date Event
1979-11-29 New Permit Application
1980-11-01 Performed Spud Operation
1980-11-11 Drilling Completion
1990-06-20 NEWLY DRILLED
1994-07-22 Drilling Completion
1994-07-22 FULLY PLUGGED

For data sources see[4]



Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
556944 Primary Facility 1991-08-12 Routine/Complete Inspection Violation(s) Noted
567047 Primary Facility 1994-07-20 Plugging(Includes Plugged/Mined Through) No Violations Noted
569682 Primary Facility 1995-05-25 Routine/Complete Inspection No Violations Noted

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
556944 94788 08/12/1991 1991-08-12 201TAG - Failure to install, in a permanent manner, the permit number on a completed well Administrative
556944 94789 08/12/1991 1991-08-12 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used Administrative
556944 94790 08/12/1991 1991-08-12 215 - Failure to bond well, replace or maintain bond Administrative

For data sources see[5]