If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-085-22067 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.254318,"lon":-80.501151,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Mercer | |
Municipality: Sharon City | |
Operator Name: EXCO RESOURCES PA LLC | |
Well Pad ID: | |
Farm/Lease Name: TAYLOR SUPPLY CO 1 | |
License Status: ACTIVE | |
Spud Date: | |
Permit Date: 1995-01-12 | |
Well Type: GAS | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Conservation: Yes | |
Latitude: 41.254318 | |
Longitude: -80.501151 |
Date | Event |
---|---|
1995-01-12 | New Permit Application |
1995-01-18 | Performed Spud Operation |
1995-01-24 | Drilling Completion |
1995-02-04 | Perforation |
1996-06-07 | NEWLY DRILLED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
1998 | EXCO RESOURCES PA INC | 6087 | 365 | 0.00 | 0 | 0.00 | 0 |
1999 | EXCO RESOURCES PA INC | 6558 | 31 | 165 | 31 | 0.00 | 0 |
2000 | EXCO RESOURCES PA INC | 6410 | 365 | 87 | 365 | 0.00 | 0 |
2001 | EXCO RESOURCES PA INC | 5499 | 365 | 77 | 365 | 0.00 | 0 |
2004 | EXCO RESOURCES PA INC | 4727 | 365 | 91.14 | 365 | 0.00 | 0 |
2005 | EXCO RESOURCES PA INC | 4,408.00 | 365 | 81.15 | 365 | 0.00 | 0 |
2006 | EXCO RESOURCES PA INC | 3,916.00 | 365 | 53.75 | 365 | 0.00 | 0 |
2007 | EXCO RESOURCES PA INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2008 | EXCO RESOURCES PA INC | 3538.00 | 366 | 68.10 | 366 | 0.00 | 0 |
2009 | EXCO RESOURCES PA INC | 3420.00 | 365 | 87.00 | 365 | 0.00 | 0 |
2010 | EXCO RESOURCES PA INC | 3,290.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2011 | EXCO RESOURCES PA INC | 3,146.00 | 365 | 80.00 | 365 | 0.00 | 0 |
2012 | EXCO RESOURCES PA LLC | 1,897.00 | 335 | 0.00 | 0 | 0.00 | 0 |
2013 | EXCO RESOURCES PA LLC | 1,102.00 | 89 | 0.00 | 0 | 0.00 | 0 |
2014 | EXCO RESOURCES PA LLC | 4,003.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | EXCO RESOURCES PA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | ALLIANCE PETRO CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | EXCO RESOURCES PA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2018 | EXCO RESOURCES PA LLC | 0.00 | 0 | 81.83 | 1 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2005 | EXCO RESOURCES PA INC | Brine | 40.00 Bbl | Injection Disposal Well | OH-2403 |
2006 | EXCO RESOURCES PA INC | Brine | 6.00 Bbl | Injection Disposal Well | OH-2403 |
2009 | EXCO RESOURCES PA INC | Brine | 5.00 Bbl | Injection Disposal Well | OH-2403 |
2018 | EXCO RESOURCES PA LLC | Servicing Fluid | 270.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0101508 |
2018 | EXCO RESOURCES PA LLC | Other Oil & Gas Wastes | 183.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095273 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2762541 | Primary Facility | 2018-08-10 | Routine/Partial Inspection | No Violations Noted | GPS coordinates taken with inspection app 41.254318 -80.501151.
GPS coordinates on NOI used to find well 41.2543415 -80.5015465. Tubing currently shut. Production casing has an open valve that appears to go to abandoned factory. |
2765388 | Primary Facility | 2018-08-16 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | When arrived on site no rig. Rig crew had finishing removing brush and metal pipes from around well. Had finished digging up well head. Stated that they planned to lay containment Monday and rig up. They would have security patrolling the area the prevent vandalism of equipment. |
2766808 | Primary Facility | 2018-08-23 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Well had pressure. Killed well with fresh water. KLX Energy Services wireline used to set CIBP. |
2768243 | Primary Facility | 2018-08-28 | Routine/Partial Inspection | No Violations Noted | CIBP set @ 4766
150' cement plug @ 4766'-4616' with 12 sks cement Cut 4-1/2" production casing 3290' 150' cement plug @ 3290'-3140' with 72 sks cement 200' cement plug @ 3090'-2890' with 96 sks cement Plan to let cement plugs set over night and set casing seat plug 8/29/18. |
2768246 | Primary Facility | 2018-08-14 | Routine/Partial Inspection | No Violations Noted | No rig onsite yet. Rig crew clearing around well to be able to rig up and area to work. |
2770492 | Primary Facility | 2018-09-04 | Routine/Partial Inspection | No Violations Noted | Service rig, back hoe, fork lift, frac tank, 1-1/2" tubing still on site. Separator and brine tank still in dike area. Well has not been cut off and put below plow depth yet. A bucket is currently on top off well. Plugging certificate due within 30 days of completion of plug job. |
2772940 | Primary Facility | 2018-09-10 | Routine/Complete Inspection | No Violations Noted | Routine inspection of plug job and related restoration needs. Well is plugged. Operator will install monument. Open, line pit from plug job on site. Box tank and other equipment on site. Tank battery has 100 bbl steel tank, 50 bbl steel tank, and separator in earthen dike. No issues during inspection. |
2780300 | Primary Facility | 2018-09-27 | Routine/Complete Inspection | No Violations Noted | Routine inspection to check status of plug job and associated restoration work at Taylor Supply 1 well. Abandoned industrial site. No personnel on site. One high-lift parked by well. Skid with separator and both tanks (steel 100 and 50 bbl tanks) has been pulled out of the earthen dike. Pit and contents have been removed and back-filled. No issues during inspection. |
2807451 | Primary Facility | 2018-11-28 | Routine/Complete Inspection | No Violations Noted | Routine inspection of recently plugged well. No equipment, tanks, or production unit on site. Site is snow-covered. Tubing monument erected at wellhead has API # welded into steel plate (photo 1). No issues at this time. Will inspect again when snow is gone. |
568818 | Primary Facility | 1995-01-24 | Drilling/Alteration | No Violations Noted | |
572243 | Primary Facility | 1996-04-09 | Routine/Complete Inspection | No Violations Noted |
For data sources see[7]