37-085-22067

Well Details

Well ID: 37-085-22067
Loading map...
Country: United States
State: Pennsylvania
County: Mercer
Municipality: Sharon City
Operator Name: EXCO RESOURCES PA LLC
Well Pad ID:
Farm/Lease Name: TAYLOR SUPPLY CO 1
License Status: ACTIVE
Spud Date:
Permit Date: 1995-01-12
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: Yes
Latitude: 41.254318
Longitude: -80.501151

For data sources see[1][2][3]

Well History

Date Event
1995-01-12 New Permit Application
1995-01-18 Performed Spud Operation
1995-01-24 Drilling Completion
1995-02-04 Perforation
1996-06-07 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
1998 EXCO RESOURCES PA INC 6087 365 0.00 0 0.00 0
1999 EXCO RESOURCES PA INC 6558 31 165 31 0.00 0
2000 EXCO RESOURCES PA INC 6410 365 87 365 0.00 0
2001 EXCO RESOURCES PA INC 5499 365 77 365 0.00 0
2004 EXCO RESOURCES PA INC 4727 365 91.14 365 0.00 0
2005 EXCO RESOURCES PA INC 4,408.00 365 81.15 365 0.00 0
2006 EXCO RESOURCES PA INC 3,916.00 365 53.75 365 0.00 0
2007 EXCO RESOURCES PA INC 0.00 0 0.00 0 0.00 0
2008 EXCO RESOURCES PA INC 3538.00 366 68.10 366 0.00 0
2009 EXCO RESOURCES PA INC 3420.00 365 87.00 365 0.00 0
2010 EXCO RESOURCES PA INC 3,290.00 365 0.00 0 0.00 0
2011 EXCO RESOURCES PA INC 3,146.00 365 80.00 365 0.00 0
2012 EXCO RESOURCES PA LLC 1,897.00 335 0.00 0 0.00 0
2013 EXCO RESOURCES PA LLC 1,102.00 89 0.00 0 0.00 0
2014 EXCO RESOURCES PA LLC 4,003.00 365 0.00 0 0.00 0
2015 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2016 ALLIANCE PETRO CO LLC 0.00 0 0.00 0 0.00 0
2017 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2018 EXCO RESOURCES PA LLC 0.00 0 81.83 1 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2005 EXCO RESOURCES PA INC Brine 40.00 Bbl Injection Disposal Well OH-2403
2006 EXCO RESOURCES PA INC Brine 6.00 Bbl Injection Disposal Well OH-2403
2009 EXCO RESOURCES PA INC Brine 5.00 Bbl Injection Disposal Well OH-2403
2018 EXCO RESOURCES PA LLC Servicing Fluid 270.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0101508
2018 EXCO RESOURCES PA LLC Other Oil & Gas Wastes 183.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2762541 Primary Facility 2018-08-10 Routine/Partial Inspection No Violations Noted GPS coordinates taken with inspection app 41.254318 -80.501151.

GPS coordinates on NOI used to find well 41.2543415 -80.5015465.

Tubing currently shut. Production casing has an open valve that appears to go to abandoned factory.

2765388 Primary Facility 2018-08-16 Plugging(Includes Plugged/Mined Through) No Violations Noted When arrived on site no rig. Rig crew had finishing removing brush and metal pipes from around well. Had finished digging up well head. Stated that they planned to lay containment Monday and rig up. They would have security patrolling the area the prevent vandalism of equipment.
2766808 Primary Facility 2018-08-23 Plugging(Includes Plugged/Mined Through) No Violations Noted Well had pressure. Killed well with fresh water. KLX Energy Services wireline used to set CIBP.
2768243 Primary Facility 2018-08-28 Routine/Partial Inspection No Violations Noted CIBP set @ 4766

150' cement plug @ 4766'-4616' with 12 sks cement Cut 4-1/2" production casing 3290' 150' cement plug @ 3290'-3140' with 72 sks cement 200' cement plug @ 3090'-2890' with 96 sks cement Plan to let cement plugs set over night and set casing seat plug 8/29/18.

2768246 Primary Facility 2018-08-14 Routine/Partial Inspection No Violations Noted No rig onsite yet. Rig crew clearing around well to be able to rig up and area to work.
2770492 Primary Facility 2018-09-04 Routine/Partial Inspection No Violations Noted Service rig, back hoe, fork lift, frac tank, 1-1/2" tubing still on site. Separator and brine tank still in dike area. Well has not been cut off and put below plow depth yet. A bucket is currently on top off well. Plugging certificate due within 30 days of completion of plug job.
2772940 Primary Facility 2018-09-10 Routine/Complete Inspection No Violations Noted Routine inspection of plug job and related restoration needs. Well is plugged. Operator will install monument. Open, line pit from plug job on site. Box tank and other equipment on site. Tank battery has 100 bbl steel tank, 50 bbl steel tank, and separator in earthen dike. No issues during inspection.
2780300 Primary Facility 2018-09-27 Routine/Complete Inspection No Violations Noted Routine inspection to check status of plug job and associated restoration work at Taylor Supply 1 well. Abandoned industrial site. No personnel on site. One high-lift parked by well. Skid with separator and both tanks (steel 100 and 50 bbl tanks) has been pulled out of the earthen dike. Pit and contents have been removed and back-filled. No issues during inspection.
2807451 Primary Facility 2018-11-28 Routine/Complete Inspection No Violations Noted Routine inspection of recently plugged well. No equipment, tanks, or production unit on site. Site is snow-covered. Tubing monument erected at wellhead has API # welded into steel plate (photo 1). No issues at this time. Will inspect again when snow is gone.
568818 Primary Facility 1995-01-24 Drilling/Alteration No Violations Noted
572243 Primary Facility 1996-04-09 Routine/Complete Inspection No Violations Noted

For data sources see[7]

References