X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-085-24295

Well Details

Well ID: 37-085-24295
Loading map...
Country: United States
State: Pennsylvania
County: Mercer
Municipality: Pymatuning Township
Operator Name: BOBCAT WELL & PIPELINE LLC
Well Pad ID:
Farm/Lease Name: GRDC 12
License Status: Plugged and Abandoned
Spud Date: 2007-08-20
Permit Date: 2007-05-10
Well Type: COMB. OIL&GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: Yes
Latitude: 41.347406
Longitude: -80.418289

For data sources see[1][2][3]

Well History

Date Event
2007-05-10 New Permit Application
2007-08-21 Performed Spud Operation
2007-08-30 Drilling Completion
2007-09-05 Perforation
2007-09-05 Performed Stimulation
2007-11-13 Newly Drilled
2017-10-23 Begin Plugging
2017-10-26 Finished Plugging

For data sources see[4]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2007-09-05 Sand 0 0 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 D & L ENERGY INC 299.4 365 0.00 0 0.00 0
2011 D & L ENERGY INC 129.4 365 0.00 0 0.00 0
2012 D & L ENERGY INC 67.8 365 0.00 0 0.00 0
2013 D & L ENERGY INC 0.00 0 0.00 0 0.00 0
2015 BOBCAT WELL & PIPELINE LLC 0.00 0 0.00 0 0.00 0
2016 BOBCAT WELL & PIPELINE LLC 0.00 0 0.00 0 0.00 0
2017 BOBCAT WELL & PIPELINE LLC 0.00 0 23.98 1 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 D & L ENERGY INC Produced Fluid 507.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 34-007-22038
2010 D & L ENERGY INC Produced Fluid 238.00 Bbl INJECTION DISPOSAL WELL 34-155-23584
2011 D & L ENERGY INC Produced Fluid 120.00 Bbl INJECTION DISPOSAL WELL 34-007-22038
2011 D & L ENERGY INC Produced Fluid 165.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 34-099-23127
2017 BOBCAT WELL & PIPELINE LLC Produced Fluid 4.00 Bbl INJECTION DISPOSAL WELL 34-155-24063

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1643872 Primary Facility 2007-08-14 Compliance Evaluation No Violations Noted
1646413 Primary Facility 2007-08-24 Drilling/Alteration No Violations Noted
1646416 Primary Facility 2007-08-27 Drilling/Alteration No Violations Noted
2476915 Primary Facility 2016-04-20 Routine/Partial Inspection Violation(s) Noted
2614793 Primary Facility 2017-07-12 Routine/Partial Inspection Violation(s) Noted
2647349 Primary Facility 2017-10-13 Routine/Partial Inspection Outstanding Violations - Viols Req'd Well is currently in violation for failure to plug upon abandonment. Received a NOI (notice of intent) to plug on 10/10/17. GPS coordinates on NOI given in DD MM SSSS converted to DDDD are 41.3474056 -80.418289. GPS coordinates in efacts are 41.347418 -80.418065. GPS coordinates taken at wellhead with inspection app are 41.34684 -80.41816.
2651439 Primary Facility 2017-10-24 Routine/Partial Inspection No Violations Noted NOI submitted 10/6/17. Informed in person 10/20/17 that rig would be onsite 10/23/17. Pumpjack moved to entrance of the access road near the dike with the tanks and separator. Rod pulled out of well. Bottom plug set 4865-4465 with 30 sks. through tubing. Second plug to be set 3594-3032 with 161 sks. depending on where production casing can be ripped. Casing seat plug to be set 737-587 with 46 sks. The 2 3/8" tubing is being tallied as it's pulled for plugging certificate. Equipment on site: bulk truck, pump truck, pipe trailer for tubing, tank, dozer, excavator, pipe trailer for production casing and service rig. Should be finished 10/25/17 and moving to next site.
2652010 Primary Facility 2017-10-25 Routine/Partial Inspection No Violations Noted The 4-1/2 production casing was ripped at about 3681'. Casing pulled up and currently pumping the second plug.
2677201 Primary Facility 2018-01-03 Administrative/File Review No Violations Noted

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2476915 757386 2016-04-20 OGA 3222(A) Administrative
2476915 757387 2016-04-20 OGA3220(A) Environmental Health & Safety
2614793 791235 2017-07-12 OGA3220(A) Environmental Health & Safety
2647349 799159 2017-10-13 OGA3220(A) Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
757386 342715 NOV - Notice of Violation
757387 342715 NOV - Notice of Violation
791235 356705 NOV - Notice of Violation

For data sources see[8]

References