37-105-21343

Well Details

Well ID: 37-105-21343
Loading map...
Country: United States
State: Pennsylvania
County: Potter
Municipality: Genesee Township
Operator Name:
Well Pad ID:
Farm/Lease Name: THOMPSON COSTELLO 3
License Status: ACTIVE
Spud Date:
Permit Date: 2007-06-12
Well Type: STORAGE WELL
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 41.931279
Longitude: -77.894162

For data sources see[1][2][3]

Well History

Date Event
2007-06-12 New Permit Application
2007-06-18 Performed Spud Operation
2007-07-29 Drilling Completion
2007-11-14 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2007 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2008 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2009 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2010 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2011 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2012 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2013 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2014 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2015 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2016 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2017 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2018 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2016 DOMINION ENERGY TRANS INC Servicing Fluid 4.18 Tons LANDFILL 301358
2017 DOMINION ENERGY TRANS INC Servicing Fluid 66.10 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1630881 Primary Facility 2007-06-14 Routine/Complete Inspection No Violations Noted
1631339 Primary Facility 2007-06-20 Drilling/Alteration No Violations Noted
1838725 Primary Facility 2009-10-21 Routine/Complete Inspection No Violations Noted
2028065 Primary Facility 2011-11-07 Routine/Complete Inspection No Violations Noted
2126116 Primary Facility 2012-11-08 Routine/Complete Inspection No Violations Noted
2232318 Primary Facility 2013-11-20 Routine/Complete Inspection No Violations Noted
2324750 Primary Facility 2014-11-25 Routine/Complete Inspection No Violations Noted
2420202 Primary Facility 2015-10-26 Routine/Complete Inspection No Violations Noted
2542792 Primary Facility 2016-10-19 Routine/Complete Inspection No Violations Noted
2646323 Primary Facility 2017-10-10 Routine/Complete Inspection No Violations Noted
2799727 Primary Facility 2018-10-22 Routine/Complete Inspection No Violations Noted At the time of this inspection the casing pressure on this well was 1998 pounds per square inch. There are one (1) annulus vent on this well. No venting as noted at this inspection. No violations noted at this inspection.

For data sources see[7]