If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-105-21522 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.853983,"lon":-77.717778,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Potter | |
Municipality: Hector Township | |
Operator Name: WATER TERRIER LLC | |
Well Pad ID: | |
Farm/Lease Name: CUSHING TRACT | |
License Status: Plugged and Abandoned | |
Spud Date: | |
Permit Date: 2008-08-12 | |
Well Type: GAS | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Conservation: Yes | |
Latitude: 41.853983 | |
Longitude: -77.717778 |
Date | Event |
---|---|
2008-08-12 | New Permit Application |
2008-09-12 | Performed Spud Operation |
2011-01-18 | New Permit Application |
2015-07-22 | Inactive Well Request Granted |
2018-11-16 | Begin Plugging |
2018-11-26 | Finished Plugging |
2019-02-07 | Fully Plugged |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2014 | WATER TERRIER LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | WATER TERRIER LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | WATER TERRIER LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | WATER TERRIER LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2018 | WATER TERRIER LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1906074 | Primary Facility | 2010-06-21 | Complaint Inspection | Violation(s) Noted | Complaint #272172 |
2004244 | Primary Facility | 2011-08-31 | Compliance Evaluation | Violation(s) & Outstanding Violations | A follow-up inspection was conducted o 8/31/11to determine if the violations noted during a 6/21/10 (1906074) inspection had been resolved. The pit was still located at the site and the liner had multiple holes in it. Also, the orange safety fence had fallen down in one area. In addition to the violation cited in June 2010 for 25 PA Code §78.65(2) - Failure to restore site within 30 days of permit expiration when well not drilled that has not yet been resolved one additional violation has been cited during this inspection for 25 PA Code §78.56(a)(3) ¿ Pits and tanks shall be designed, constructed and maintained to be structurally sound and reasonably protected from unauthorized acts of third parties. You had indicated in your response to the Notice of Violation 7009 1680 0000 0578 4803 that this pit had been removed. This is obviously not the case. MRN |
2048796 | Primary Facility | 2012-03-07 | Compliance Evaluation | Violation(s) & Outstanding Violations | The violation of 25 PA Code §78.65(2) - Failure to restore the site within 30 days of permit expiration when it was determined the well was not drilled with due diligence cited in a June 20, 2010 inspection and the violation of 25 PA Code §78.56(a)(3) – Pits and tanks shall be designed, constructed and maintained to be structurally sound and reasonably protected from unauthorized acts of third parties cited in the August 31, 2011 inspection (2004244) noted that the pit was still located at the site and the liner had multiple holes in it remain outstanding. |
2066674 | Primary Facility | 2012-05-08 | Compliance Evaluation | Outstanding Violations - No Viols Req'd | A June 21, 2010 inspection (1906074) resulted in a violation of 25 PA Code §78.65(2) - Failure to restore the site within 30 days of permit expiration when it was determined the well was not drilled with due diligence. An August 31, 2011 inspection (2004244) noted that the pit was still located at the site and the liner had multiple holes in it. Also, the orange safety fence had fallen down in one area resulting in an additional violation of 25 PA Code §78.56(a)(3) – Pits and tanks shall be designed, constructed and maintained to be structurally sound and reasonably protected from unauthorized acts of third parties. A March 7, 2012 inspection (2048796) revealed there was also no Erosion Control Plan at the site and there were no records on site documenting the maintenance program of BMPs and the inspection of BMPs on a weekly basis and after each storm event.Today's inspection showed nothing has been done so far to correct these outstanding violations. No new violations were cited during this inspection. - MRN |
2095240 | Primary Facility | 2012-08-10 | Routine/Complete Inspection | Violation(s) & Outstanding Violations | |
2216513 | Primary Facility | 2013-10-10 | Follow-up Inspection | No Violations Noted | |
2292663 | Primary Facility | 2014-08-05 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | The Department conducted a follow up inspection on 8/5/14 @ 1220 hours in Hector Twp., Potter Co. The weather is cloudy, 75 degrees with thunderstorms in the immediate area. The Operator is onsite removing portions of the liner near the surface in preparation for extraction of drill cuttings, and backfilling of the pit using large equipment. Violations cited on 3/7/12, Inspection Record #2048796, remain outstanding. No new violations issued during this inspection. |
2295675 | Primary Facility | 2014-08-13 | Compliance Evaluation | Outstanding Violations - No Viols Req'd | A site inspection was conducted at the WCP6 well in Potter County Hector Township on 13 AUG. 2014. The former drill cuttings pit has been removed, the site has been returned to original contours and has been seeded and mulched. Violations cited on 8/31/11 for the following issues are considered resolved. 1) 78.65(2) - Failure to restore site within 30 days of permit expiration when well not drilled |
2316681 | Primary Facility | 2014-10-28 | Compliance Evaluation | No Violations Noted | A site inspection was conducted at the WCP6 well in Potter County Hector Township on 28 OCT. 2014. The former drill cuttings pit has been removed, the site has been returned to original contours and has been seeded and mulched. |
2316813 | Primary Facility | 2014-10-21 | Follow-up Inspection | No Violations Noted | |
2812008 | Primary Facility | 2018-12-07 | Administrative/File Review | No Violations Noted | December 7, 2018: The Certificate of Well Plugging for the WCP6 (105-21522) has been received, reviewed, signed, and sent to file. |
2812052 | Primary Facility | 2018-12-06 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | A routine, post-plugging, inspection of this uncompleted conventional well was conducted December 6, 2018. At the time of inspection, the well has a 7" x 2" candy cane vent pipe 4' high with a marker plated erected atop 7" surface casing as a plugged well monument. There was no visible or audible venting at the vent pipe. No gas was detected at the mouth of the vent with an Altair 5x gas meter. The 7" x 9 5/8" annulus was visible at surface; no discharge, venting, or bubbling was observed. No obvious issues were observed during this inspection. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1906074 | 593143 | 06/21/2010 | 2010-06-21 | 78.65(2)* - Failure to restore site within 30 days of permit expiration when well not drilled | Environmental Health & Safety | 78.65(2). Failure to restore the well site within 30 days of the permit expiration. As per Oil and Gas Act Section 601.201(i), it has been determined that the well was not drilled with due diligence. Well permit issued 8-12-08. TLT |
2004244 | 620589 | 08/31/2011 | 2011-08-31 | 78.65(2)* - Failure to restore site within 30 days of permit expiration when well not drilled | Environmental Health & Safety | |
2004244 | 620590 | 08/31/2011 | 2011-08-31 | 78.56(3) - Impoundment not structurally sound, impermeable, 3rd party protected. | Administrative | The pit liner had multiple holes in it and the orange safety fence had fallen down in one area. MRN |
2048796 | 633687 | 03/07/2012 | 2012-03-07 | 102.4NOPLAN - No E&S plan developed, plan not on site | Administrative | The E&S Plan, inspection reports and monitoring recordsare not on site and available for review by the Department |
2048796 | 633690 | 03/07/2012 | 2012-03-07 | 78.65(2)* - Failure to restore site within 30 days of permit expiration when well not drilled | Environmental Health & Safety | |
2048796 | 633691 | 03/07/2012 | 2012-03-07 | 78.56PITCNST - Impoundment not structurally sound, impermeable, 3rd party protected, greater than 20" of seasonal high ground water table | Administrative | |
2095240 | 647743 | 08/10/2012 | 2012-08-10 | 201G - Failure to post permit number, operator name, address, telephone number in a conspicuous manner at the site during drilling | Administrative | No ID |
2095240 | 647744 | 08/10/2012 | 2012-08-10 | 78.73(a) - GENERAL PROVISION FOR WELL CONSTRUCTION AND OPERATION - Operator failed to construct and operate the well in accordance with 25 Pa. Code Chapter 78 and ensure that the integrity of the well is maintained and health, safety, environment and | Environmental Health & Safety | Insufficient barriers |
2095240 | 647747 | 08/10/2012 | 2012-08-10 | 78.77 - Failure to monitor or operate H2S Well | Environmental Health & Safety | This violation was inadventantly cited due to the OGI incorrectly reading the meter. While screening of the well during subsequest inspections, no H2S was noted |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
593143 | 261548 | NOV - Notice of Violation | Comply/Closed | 2014-10-28 | |||
633687 | 281345 | NOV - Notice of Violation | Comply/Closed | 2014-10-28 | |||
633690 | 281345 | NOV - Notice of Violation | Comply/Closed | 2014-10-28 | |||
633691 | 281345 | NOV - Notice of Violation | Comply/Closed | 2014-10-28 | |||
647743 | 334100 | COA - Consent Order and Agreement | Comply/Closed | 2016-01-28 | |||
647744 | 334100 | COA - Consent Order and Agreement | Comply/Closed | 2016-01-28 | |||
647747 | 334100 | COA - Consent Order and Agreement | Comply/Closed | 2016-01-28 |