Well Details

Well ID: 37-105-21606
Loading map...
Country: United States
State: Pennsylvania
County: Potter
Municipality: West Branch Township
Operator Name: TILDEN MARCELLUS LLC
Well Pad ID: 147893
Farm/Lease Name: BUTTON B 901 3H
License Status:
Spud Date:
Permit Date: 2009-09-18
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.672928
Longitude: -77.605579

For data sources see[1][2][3]

Well History

Date Event
2009-09-18 New Permit Application
2009-10-13 Performed Spud Operation

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 ULTRA RESOURCES INC 0.00 0 0.00 0 0.00 0
2010 ULTRA RESOURCES INC 456,672.09 137 0.00 0 0.00 0
2011 ULTRA RESOURCES INC 705,153.00 365 0.00 0 0.00 0
2012 ULTRA RESOURCES INC 432,542.00 356 0.00 0 0.00 0
2013 ULTRA RESOURCES INC 399,590.00 355 0.00 0 0.00 0
2014 SWEPI LP 307,630.57 320 0.00 0 0.00 0
2015 SWEPI LP 219,978.31 269 0.00 0 0.00 0
2016 SWEPI LP 207,461.11 349 0.00 0 0.00 0
2017 SWEPI LP 201,958.95 363 0.00 0 0.00 0
2018 SWEPI LP 185,761.53 365 0.00 0 0.00 0
2019 SWEPI LP 162,361.22 350 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 ULTRA RESOURCES INC Produced Fluid 9,084.50 Bbl REUSE OTHER THAN ROAD SPREADING
2013 ULTRA RESOURCES INC Produced Fluid 135.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013 ULTRA RESOURCES INC Produced Fluid 135.30 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2013 ULTRA RESOURCES INC Produced Fluid 19.20 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2014 ULTRA RESOURCES INC Produced Fluid 131.20 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015 SWEPI LP Produced Fluid 203.95 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WVD988782532
2015 SWEPI LP Produced Fluid 650.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2015 SWEPI LP Produced Fluid 125.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SWEPI LP Produced Fluid 216.00 Bbl RESIDUAL WASTE TRANSFER FACILITY 7-3115-00193
2016 SWEPI LP Other Oil & Gas Wastes 20.50 Bbl RESIDUAL WASTE TRANSFER FACILITY 7-3115-00193
2016 SWEPI LP Produced Fluid 24.04 Bbl RESIDUAL WASTE TRANSFER FACILITY 7-3115-00193
2016 SWEPI LP Other Oil & Gas Wastes 2.68 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WVD988782532
2017 SWEPI LP Produced Fluid 100.08 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 SWEPI LP Produced Fluid 0.10 Bbl LANDFILL 301358
2018 SWEPI LP Produced Fluid 159.84 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 TILDEN MARCELLUS LLC Produced Fluid 220.50 Bbl STORAGE PENDING DISPOSAL OR REUSE WMGR123NC036
2019 TILDEN MARCELLUS LLC Produced Fluid 883.00 Bbl REUSE (AT WELL PAD)
2019 SWEPI LP Other Oil & Gas Wastes 15.31 Bbl RESIDUAL WASTE TRANSFER FACILITY 7-3115-00193
2019 TILDEN MARCELLUS LLC Other Oil & Gas Wastes 4.50 Bbl REUSE (AT WELL PAD)

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1852312 Primary Facility 2009-12-23 Routine/Partial Inspection Violation(s) Noted Improperly lined impoundments, lack pollution containing measures for polluting substances, no E&S plan availalable on site
1852480 Primary Facility 2009-12-22 Drilling/Alteration Violation(s) Noted
1860402 Primary Facility 2010-02-02 Follow-up Inspection De minimus Violations Noted had some small holes in top edge of one drill pit liner but freeboard was good, E&S Plat on site did not have registered professional seal/signature
1860424 Primary Facility 2010-01-25 Routine/Complete Inspection Violation(s) Noted
1864630 Primary Facility 2010-02-22 Compliance Evaluation No Violations Noted
1879352 Primary Facility 2010-04-23 Routine/Partial Inspection No Violations Noted
1888284 Primary Facility 2010-05-28 Routine/Partial Inspection Violation(s) Noted New ESCGP Plan not on site and some of silt soxx needs staked in and bermed to inside - See Insp ID 1889613 done 6/7/10, past 102.4 viols corrected.
1889613 Primary Facility 2010-06-07 Compliance Evaluation No Violations Noted
1947954 Primary Facility 2011-02-04 Routine/Partial Inspection No Violations Noted
1954376 Primary Facility 2011-02-28 Routine/Partial Inspection No Violations Noted
1966429 Primary Facility 2011-04-05 Routine/Partial Inspection No Violations Noted
1990084 Primary Facility 2011-07-21 Routine/Complete Inspection No Violations Noted
2002409 Primary Facility 2011-09-13 Routine/Complete Inspection No Violations Noted
2012133 Primary Facility 2011-10-17 Follow-up Inspection No Violations Noted
2023760 Primary Facility 2011-12-01 Follow-up Inspection No Violations Noted Details of the inspection and photos are documented on the 1 H inspection report (2023735) - MRN
2040165 Primary Facility 2012-01-31 Routine/Complete Inspection No Violations Noted
2051336 Primary Facility 2012-02-16 Routine/Complete Inspection No Violations Noted
2150290 Primary Facility 2013-03-21 Routine/Partial Inspection No Violations Noted An inspection of the Button B 901 pad in West Branch Township, Potter County was conducted on March 21, 2013. There are six drill permits associated with this site. The 3H, 4H and 5H wells are on active status, the 2H well has been reported not drilled by the operator and the 1H and 6H wells have been placed on Regulatory Inactive Status. The pad was partially snow covered at the time of this inspection. No puddles exhibiting elevated conductivity or erosion issues were observed at this time. No violations were cited during this inspection.
2211910 Primary Facility 2013-10-10 Routine/Partial Inspection No Violations Noted On October 10, 2013 an inspection was conducted at the Button B 901 pad in West Branch Township, Potter County. The last inspection conducted on behalf of the operator was on 10/8/13. The site is stabilized and no erosion issues were noted. Several puddles were screened and none exhibited elevated conductance. No violations were cited during this inspection.
2329884 Primary Facility 2014-11-21 Routine/Complete Inspection No Violations Noted
2444049 Primary Facility 2016-01-26 Routine/Complete Inspection No Violations Noted Routine inspection. SWEPI acquired wells from Ultra Resources on 10/31/14. Four wells were drilled by Ultra (3H, 4H, 1H & 6H). Interim restoration not yet completed. SWEPI to submit a request in 2016 to extend the restoration requirements for the site. The site is permanently stabilized and the pad surface has been vegetated, except for the access road. Two water impoundments are at the site--the smaller impoundment was approximately 1/4 full and the larger impoundment was near capacity. Both impoundments were frozen over and snow covered. No violations cited. TLT
2461475 Primary Facility 2016-02-29 Routine/Complete Inspection No Violations Noted
2571711 Primary Facility 2017-03-15 Routine/Complete Inspection No Violations Noted
2623340 Primary Facility 2017-08-07 Site Restoration No Violations Noted On 8/7/17 at 1055 hrs I conducted an inspection of the Button 901 well site. SWEPI employee, Chris Citrino, arrived during the inspection. It was overcast with showers and 60 degrees F.

I observed the site (Photo #1) and reviewed the erosion and sediment (E&S) routine inspection log, the Notice of Termination (NOT) and the Well Site Restoration Report (WSRR).

The site consists of the well pad, compressor pad and two freshwater impoundments. Four wells, the 1H, 3H, 4H and 6H, have been drilled. According to DEP records, the 3H and 4H wells are in production; the 1H and 6H were placed on inactive status in 2012.

The compressor pad is located across Pigeon Hill Road from the well pad. Produced water is stored in a production tank, which is staged in secondary containment (Photo #4). A 55-gallon drum was observed in the production tank containment (Photo #5); it was labeled "pipeline water" and dated 10/17/16. Standing water in containment had a field measured specific conductance of 2,350 micro Siemens/cm; t

2658988 Primary Facility 2017-11-09 Routine/Complete Inspection No Violations Noted Routine inspection of the Button pad following the plug and abandonment of two uncompleted wells. The 1H and 6H were plugged, cut, capped and buried. No obvious issues were observed at the wells' surface locations. The 3H and 4H were in production at the time of inspection. I conducted a visual inspection of the wells. Both wells had a production tree in place with plunger lift, gauges on wing valves for production csg pressure, and backside of production casing vented. The cellars were full of gravel. No irregular pressures or obvious issues were observed.
2685674 Primary Facility 2018-01-22 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was in production. The wellhead assembly all fittings and flow lines were tested for gas. Results of this testing was that gas was detected on the 9 5/8" x 5 1/2" vented annulus. No other gas was detected on the wellhead assembly or the well area.
2831281 Primary Facility 2019-01-24 Routine/Complete Inspection No Violations Noted At the time of this inspection this well in production. A digital gauge on the well head assembly was showing a pressure of 253 psi (pounds per square inch). The valve on the production/flow line was in the open position. A single annulus vent that is the intermediate x production was tested for combustible gas with the results being 100% LEL (lower explosion limit) and 37% METHNE. No other annulus vents are vented to surface at this well. No violations noted at this inspection.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1852312 578527 12/23/2009 2009-12-23 102.4NOPLAN - No E&S plan developed, plan not on site Administrative See Insp ID 1864630 on 2/22/10, company response rec'vd 2/2/10 adequate, past viols closed.
1852312 578528 12/23/2009 2009-12-23 78.56LINER - Improperly lined pit Administrative See Insp ID 1864630 on 2/22/10, company response rec'vd 2/2/10 adequate, past viols closed.
1852480 578585 12/22/2009 2009-12-22 78.56LINER - Improperly lined pit Administrative See Insp ID 1864630 on 2/22/10, company response rec'vd 2/2/10 adequate, past viols closed. 78.56(a)(1) pits/tanks or series of same not constructed and maintained w.sufficient capacity to contain pollutional substances.
1852480 578586 12/22/2009 2009-12-22 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used Administrative See Insp ID 1864630 on 2/22/10, company response rec'vd 2/2/10 adequate, past viols closed. SWMA 6018.301 drilling mud released to ground.
1852480 578669 12/22/2009 2009-12-22 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used Administrative See Insp ID 1864630 on 2/22/10, company response rec'vd 2/2/10 adequate, past viols closed. CSL 691.402(a) danger of pollution to waters created.
1860424 580599 01/25/2010 2010-01-25 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used Administrative See Insp ID 1864630 on 2/22/10, company response rec'vd 2/2/10 adequate, past viols closed. SWMA 301 drill mud +/or cuttings released to ground surface.
1860424 580600 01/25/2010 2010-01-25 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used Administrative See Insp ID 1864630 on 2/22/10, company response rec'vd 2/2/10 adequate, past viols closed. CSL 402(a) drill mud +/or cuttings pose potential to pollute.
1860424 580601 01/25/2010 2010-01-25 78.56LINER - Improperly lined pit Administrative See Insp ID 1864630 on 2/22/10, company response rec'vd 2/2/10 adequate, past viols closed. 78.56(a)(1) failure to contain pollutional substances.
1860424 580602 01/25/2010 2010-01-25 78.56FRBRD - Failure to maintain 2' freeboard in an impoundment Administrative See Insp ID 1864630 on 2/22/10, company response rec'vd 2/2/10 adequate, past viols closed. 78.56(a)(2) failure to maintain >= 2 ft freeboard.
1888284 588366 05/28/2010 2010-05-28 102.4NOPLAN - No E&S plan developed, plan not on site Administrative See Insp ID 1889613 done 6/7/10, past 102.4 viols corrected.
1888284 588367 05/28/2010 2010-05-28 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety See Insp ID 1889613 done 6/7/10, past 102.4 viols corrected.

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
578527 253848 NOV - Notice of Violation Comply/Closed 2010-02-22
578528 253848 NOV - Notice of Violation Comply/Closed 2010-02-22
578585 253848 NOV - Notice of Violation Comply/Closed 2010-02-22
578586 253848 NOV - Notice of Violation Comply/Closed 2010-02-22
578669 253848 NOV - Notice of Violation Comply/Closed 2010-02-22
580599 254920 NOV - Notice of Violation Comply/Closed 2010-02-22
580600 254920 NOV - Notice of Violation Comply/Closed 2010-02-22
580601 254920 NOV - Notice of Violation Comply/Closed 2010-02-22
580602 254920 NOV - Notice of Violation Comply/Closed 2010-02-22

For data sources see[7]