37-105-21618

Well Details

Well ID: 37-105-21618
Loading map...
Country: United States
State: Pennsylvania
County: Potter
Municipality: West Branch Township
Operator Name: TILDEN MARCELLUS LLC
Well Pad ID: 148661
Farm/Lease Name: KEN TON 902 6H
License Status:
Spud Date:
Permit Date: 2009-10-06
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.685872
Longitude: -77.604192

For data sources see[1][2][3]

Well History

Date Event
2009-10-06 New Permit Application
2010-03-25 Performed Spud Operation
2010-07-24 Drilling Completion
2010-10-04 Perforation
2011-04-08 DEVIATED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 ULTRA RESOURCES INC 0.00 0 0.00 0 0.00 0
2010 ULTRA RESOURCES INC 71,648.67 59 0.00 0 0.00 0
2011 ULTRA RESOURCES INC 155,158.60 365 0.00 0 0.00 0
2012 ULTRA RESOURCES INC 211,383.00 366 0.00 0 0.00 0
2013 ULTRA RESOURCES INC 166,012.00 353 0.00 0 0.00 0
2014 SWEPI LP 135,828.45 323 0.00 0 0.00 0
2015 SWEPI LP 87,313.28 253 0.00 0 0.00 0
2016 SWEPI LP 106,415.95 350 0.00 0 0.00 0
2017 SWEPI LP 130,704.81 364 0.00 0 0.00 0
2018 SWEPI LP 110,813.42 359 0.00 0 0.00 0
2019 SWEPI LP 100,153.55 355 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 ULTRA RESOURCES INC Produced Fluid 61.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 ULTRA RESOURCES INC Produced Fluid 63.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013 ULTRA RESOURCES INC Produced Fluid 107.20 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2013 ULTRA RESOURCES INC Produced Fluid 15.40 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2014 ULTRA RESOURCES INC Produced Fluid 105.90 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015 SWEPI LP Produced Fluid 68.93 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WVD988782532
2015 SWEPI LP Fracing Fluid Waste 116.69 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SWEPI LP Produced Fluid 16.67 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2015 SWEPI LP Produced Fluid 34.62 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 SWEPI LP Produced Fluid 59.35 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWEPI LP Produced Fluid 213.71 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWEPI LP Produced Fluid 66.66 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017 SWEPI LP Waste Water Treatment Sludge 3.29 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017 SWEPI LP Produced Fluid 249.83 Bbl REUSE (AT WELL PAD)
2018 SWEPI LP Produced Fluid 47.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 SWEPI LP Produced Fluid 233.34 Bbl REUSE (AT WELL PAD)
2018 SWEPI LP Produced Fluid 34.22 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 SWEPI LP Produced Fluid 250.02 Bbl REUSE (AT WELL PAD)
2019 TILDEN MARCELLUS LLC Produced Fluid 33.34 Bbl STORAGE PENDING DISPOSAL OR REUSE WMGR123NC036

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1937838 Primary Facility 2010-12-10 Routine/Partial Inspection Violation(s) Noted No well tag
1949343 Primary Facility 2011-02-11 Follow-up Inspection No Violations Noted
1970025 Primary Facility 2011-04-27 Routine/Partial Inspection No Violations Noted
2003879 Primary Facility 2011-09-13 Routine/Complete Inspection No Violations Noted
2044470 Primary Facility 2012-02-16 Routine/Complete Inspection No Violations Noted
2125962 Primary Facility 2012-12-04 Routine/Complete Inspection No Violations Noted
2190172 Primary Facility 2013-08-08 Routine/Partial Inspection No Violations Noted On August 8, 2013 an inspection was conducted at the Ken-Ton 902 pad in West Branch Township, Potter County. The 1H, 2H, 3H, 4H, 5H and 6H wells are drilled and are in production. The 7V well is drilled, but not in production, the status of the well is Inactive. The 9H well is not drilled, but the permit is active. The well permits posted on site are destroyed / missing, the site ID sign is in need of repair and updating. The site is stable and well vegetated. The conductance of the puddles screened on the pad surface ranged from 200 - 850uS/cm. No issues were noted and no violations were cited during this inspection.
2317673 Primary Facility 2014-10-28 Routine/Complete Inspection No Violations Noted Routine inspection. 1H - 6H & 7V wells are drilled. Ultra Resources completed site restoration. Site to be transferred to SWEPI LP. TLT
2329955 Primary Facility 2014-11-21 Routine/Complete Inspection No Violations Noted
2461481 Primary Facility 2016-02-29 Routine/Complete Inspection No Violations Noted
2571169 Primary Facility 2017-03-13 Routine/Complete Inspection No Violations Noted
2587263 Primary Facility 2017-04-26 Routine/Partial Inspection No Violations Noted Areas of the pad surface have been vegetated. Impervious area have been minimized. No erosion issues were noted. No violations were cited during this inspection
2623197 Primary Facility 2017-08-07 Site Restoration No Violations Noted On 8/7/17 at 0902 hrs I conducted an inspection of the Ken Ton 902 well site. No one was present during the inspection. It was overcast and 61 degrees F.

I observed the site and reviewed the erosion and sedimentation (E&S) routine inspection log, the Notice of Termination (NOT) and the Well Site Restoration Report (WSRR).

The site consists of the access road and well pad. Seven wells, the Ken Ton 1H - 6H and 7V (Photos #1-3), have been drilled. According to DEP records, the 1H - 6H wells are in production. The 7V well was placed on inactive status on 1/29/13.

Produced water is stored in a production tank, which has built-in containment (Photo #4). Routine secondary containment inspections are being completed; the last inspection was on 8/5/17. Puddles on the pad surface were tested for field measured specific conductance; readings ranged between 531 - 1,030 micro Siemens/cm.

The well site has been restored and post-construction stormwater management (PCSM) BMPs have been installed (Photo #4). Temporary E

2643548 Primary Facility 2017-09-12 Routine/Complete Inspection No Violations Noted Well design is a surface casing 13 3/8", a 9 5/8" intermediate and a 5 1/2" production string. The 5 1/2" production string is vented to surface.
2684460 Primary Facility 2018-01-17 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was producing. The wellhead assembly all fittings and flow lines were tested for gas. The results of this testing was that gas was detected on the 9 5/8" x 5 1/2" vented annulus. No other gas was detected on the wellhead assembly or the well area.
2751244 Primary Facility 2018-07-12 Routine/Complete Inspection No Violations Noted The DEP conducted a routine inspection of the SWEPI LP-Ken Ton 902 well site located in Elk Township, Tioga County on July 12, 2018 @1200 hrs. No one was present during the inspection. The weather was 74 degrees and sunny, humidity 38%, winds NNE 5mph.

I observed the access road and well pad. The site consists of seven wells, the Ken Ton 1H - 6H and 7V have been drilled. According to DEP records, the 1H - 6H wells are in production. The 7V well was placed on inactive status on 1/29/13.

Produced water is stored in a production tank, which has built-in containment. Routine tank inspections are being completed; the last inspection was on 6/12/18.

The well site has been restored and post-construction stormwater management (PCSM) BMPs have been installed. The NOT was approved on 8/7/2018.

No violations are noted at this time. I departed the site at 1315 hours.

2831151 Primary Facility 2019-01-24 Routine/Complete Inspection No Violations Noted At the time of this inspection this well in production. A digital gauge on the well head assembly was showing a pressure of 330 psi (pounds per square inch). The valve on the production/flow line was in the open position. A single annulus vent that is the intermediate x production was tested for combustible gas with the results being 100% LEL (lower explosion limit) and 6% METHNE. No other annulus vents are vented to surface at this well. No violations noted at this inspection.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1937838 601597 12/10/2010 2010-12-10 201H - Failure to properly install the permit number, issued by the department, on a completed well. Administrative

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
601597 266464 NOV - Notice of Violation Comply/Closed 2011-02-11

For data sources see[7]

References