If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-105-21645 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.688849,"lon":-77.661271,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Potter | |
Municipality: West Branch Township | |
Operator Name: TILDEN MARCELLUS LLC | |
Well Pad ID: 149018 | |
Farm/Lease Name: PAUL 906 3H | |
License Status: Inactive | |
Spud Date: 2010-03-11 | |
Permit Date: 2010-02-02 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.688849 | |
Longitude: -77.661271 |
Date | Event |
---|---|
2010-02-02 | New Permit Application |
2010-03-11 | Performed Spud Operation |
2011-03-07 | Drilling Completion |
2011-05-11 | Perforation |
2012-01-11 | DEVIATED |
2019-01-16 | Inactive Well Request Granted |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2011-05-15 | 2011-05-15 | 6,443 | 2,978,425 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | J609 | Schlumberger | Friction Reducer | Ammonium sulfate | 7783-20-2 | 30.00 | 0.03 | |
A264 Corrosion Inhibitor | Schlumberger | Corrosion Inhibitor | Methanol | 67-56-1 | 40.00 | 0.00012800 | ||
Aliphatic acids | 30.00 | 0.00009600 | ||||||
Propargyl alcohol | 107-19-7 | 10.00 | 0.00003200 | |||||
Aliphatic alcohols, ethoxylated #1 | 30.00 | 0.00009600 | ||||||
Scale Inhibitor B317 | Schlumberger | Scale Inhibitor | Trisodium phosphate | 7601-54-9 | 5.00 | 0.00072000 | ||
Ethylene glycol | 107-21-1 | 5.00 | 0.00072000 | |||||
L058 | Schlumberger | Iron Control | Sodium erythorbate | 6381-77-7 | 100.00 | 0.00020600 | ||
Sand | Schlumberger | Proppant | Quartz | 14808-60-7 | 100.00 | 14.49 | ||
Water | 100.00 | 85.16 | ||||||
BioRid 20L | Tetra | Biocide | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 20.00 | 0.00272300 | ||
Sodium bromide | 7647-15-6 | 15.00 | 0.00204200 | |||||
15 HCl | Schlumberger | Acid | Hydrochloric Acid | 15.00 | 0.05 | |||
Gelling Agent J580 | Schlumberger | Gelling Agent | Carbohydrate polymer | 100.00 | 0.00944100 | |||
J218 Breaker | Schlumberger | Breaker | Peroxydisulfuric acid, diammonium salt | 7727-54-0 | 100.00 | 0.00162500 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | ULTRA RESOURCES INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | ULTRA RESOURCES INC | 110,740.00 | 195 | 0.00 | 0 | 0.00 | 0 |
2012 | ULTRA RESOURCES INC | 135,540.00 | 358 | 0.00 | 0 | 0.00 | 0 |
2013 | ULTRA RESOURCES INC | 111,063.00 | 353 | 0.00 | 0 | 0.00 | 0 |
2014 | SWEPI LP | 89,089.61 | 321 | 0.00 | 0 | 0.00 | 0 |
2015 | SWEPI LP | 62,182.34 | 153 | 0.00 | 0 | 0.00 | 0 |
2016 | SWEPI LP | 59,988.91 | 233 | 0.00 | 0 | 0.00 | 0 |
2017 | SWEPI LP | 23,449.53 | 82 | 0.00 | 0 | 0.00 | 0 |
2019 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2013 | ULTRA RESOURCES INC | Produced Fluid | 606.40 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2013 | ULTRA RESOURCES INC | Produced Fluid | 1,401.40 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2013 | ULTRA RESOURCES INC | Produced Fluid | 100.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2014 | ULTRA RESOURCES INC | Produced Fluid | 1,012.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2015 | SWEPI LP | Produced Fluid | 100.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2016 | SWEPI LP | Produced Fluid | 1,819.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SWEPI LP | Produced Fluid | 200.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | SWEPI LP | Produced Fluid | 499.99 Bbl | REUSE (AT WELL PAD) | |
2018 | SWEPI LP | Produced Fluid | 100.00 Bbl | REUSE (AT WELL PAD) | |
2018 | SWEPI LP | Servicing Fluid | 211.66 Bbl | LANDFILL | 301358 |
2018 | SWEPI LP | Produced Fluid | 1.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1864677 | Primary Facility | 2010-02-22 | Routine/Partial Inspection | De minimus Violations Noted | Site under construction noted minor temporary E&S control BMP violations |
1869835 | Primary Facility | 2010-03-15 | Routine/Partial Inspection | De minimus Violations Noted | |
1876504 | Primary Facility | 2010-04-13 | Routine/Partial Inspection | No Violations Noted | |
1949307 | Primary Facility | 2011-02-11 | Routine/Partial Inspection | No Violations Noted | |
1952104 | Primary Facility | 2011-02-24 | Drilling/Alteration | No Violations Noted | |
1954150 | Primary Facility | 2011-02-28 | Routine/Partial Inspection | No Violations Noted | |
1967123 | Primary Facility | 2011-04-20 | Routine/Partial Inspection | Violation(s) Noted | Cuttings and caked up drilling mud around well cellar, RCE needs repaired, E&S inspection overdue |
1969790 | Primary Facility | 2011-05-02 | Follow-up Inspection | No Violations Noted | |
1989461 | Primary Facility | 2011-07-21 | Routine/Complete Inspection | No Violations Noted | |
2007876 | Primary Facility | 2011-10-04 | Routine/Complete Inspection | No Violations Noted | |
2051258 | Primary Facility | 2012-03-13 | Routine/Complete Inspection | Pending | A routine inspection was conducted at the Paul B 901 pad on March 13, 2012. The 3H well is drilled and the 6H has been spudded. AMEC conducted an inspection sometime between March 5 and March 12, 2012, the actual inspection date was not specified on the inspection report. The site ID sign was present, well drilling permits posted and the Erosion and Sedimentation (E&S) control plan was on site. All E&S BMPs were established and maintained. The fill slopes on the back of the pad will need to be monitored to ensure perennial vegetation is established to reduce the potential for accelerated erosion. A small puddle was observed near the steps to the production tank containment. The puddle exhibited elevated reading for specific conductance. A soil sample was collected and submitted for analysis. Violations may be cited pending the results of the sample. The area should be screened to determine the extent of the release and a plan to remediate the area should be submitted to the Department. - MRN |
2058842 | Primary Facility | 2012-04-12 | Follow-up Inspection | Pending | A follow up inspection was conducted at the Paul 906 pad on April 12, 2012. During a previous inspection conducted on March 13, 2012 (2051258) a small puddle was observed near the steps to the production tank containment. The puddle exhibited elevated reading for specific conductance. The n area has been excavated and soil samples collected by Ultra and submitted for analysis. During today's inspection, a puddle in the excavated area was screened with the conductivity fieled meter and a reading of 4.64µS was found. A reading of the fluid inside the secondary containment was taken and was found to be 7.28µS. Violations will remain pending at this time. No new violations were cited during this inspection. - MRN |
2062519 | Primary Facility | 2012-04-26 | Follow-up Inspection | Pending | An inspection was conducted at the Paul pad on April 26, 2012 at approximately 1345 to follow -up on the clean-up of a release discovered on March 13, 2012. During the inspection conducted on March 13, 2012 (2051258) a small puddle was observed near the steps to the production tank containment. The puddle exhibited elevated reading for specific conductance. The area has been excavated and soil samples collected by Ultra and submitted for analysis. During an inspection conducted on April 12, 2012 a puddle in the excavated area was screened with the conductivity field meter and a reading of 4.64µS was found. The results of the soil samples collected by Ultra indicated the presence of chloride at a level of 1,600mg/kg. On April 26, the day of this inspection, the area was excavated further and screened by AMEC using a conductivity probe. AMEC and DEP then collected soils samples from the bottom of the excavation area. - MRN |
2064705 | Primary Facility | 2012-04-17 | Routine/Complete Inspection | No Violations Noted | |
2153159 | Primary Facility | 2013-04-01 | Routine/Partial Inspection | No Violations Noted | An inspection of the Paul 906 pad in West Branch Township, Potter County was conducted on April 1, 2013. There are six drill permits associated with this site. The 3H and 4H wells are on active status, the 1H, 2H and 5H wells have been reported not drilled by the operator and the 6H well has been placed on Regulatory Inactive Status. The 3H well is the only well in production. The pad was partially snow covered at the time of this inspection. What could be seen was either well vegetated or stabilized with stone. No puddles exhibiting elevated conductivity or erosion issues were observed at this time. No violations were cited during this inspection. |
2447005 | Primary Facility | 2016-02-02 | Routine/Complete Inspection | No Violations Noted | Routine inspection. The 3H well is in production. The 6H well has been topholed and is on inactive status. Both wells were tagged. The impoundment contains water, which was frozen, and was near capacity. Recommended that the impoundment be pumped down to increase freeboard. The site is permanently stabilized, although is not restored. SWEPI intends to submit an extension request for the restoration requirements in 2016. TLT |
2461487 | Primary Facility | 2016-03-01 | Routine/Complete Inspection | No Violations Noted | |
2478506 | Primary Facility | 2016-04-22 | Routine/Partial Inspection | No Violations Noted | Partial inspection. Site has recently been reclaimed. Post construction stormwater management BMPs have been installed and disturbed areas temporarily stabilized. TLT |
2533017 | Primary Facility | 2016-10-28 | Site Restoration | No Violations Noted | Restoration inspection. Notice of Termination (NOT) and Well Site Restoration Reports (WSRRs) received on 10/19/16. Interim restoration of the well site was completed in April 2016 and included installation of infiltration berms beyond the north corner of the well pad. The site is permanently stabilized as per 25 Pa Code §102.22(a)(2), temporary E&S controls have been removed and post-construction stormwater management BMP’s are in place. Recommend approval of the NOT. The WSRRs were acknowledged on 10/28/16. TLT |
2576281 | Primary Facility | 2017-03-28 | Routine/Complete Inspection | No Violations Noted | |
2587157 | Primary Facility | 2017-04-26 | Routine/Partial Inspection | No Violations Noted | The well pad area has been minimized and impervious area reduced. Post construction best management practices are installed and functional no staining or puddles or found at the pad surface |
2684740 | Primary Facility | 2018-01-17 | Routine/Complete Inspection | No Violations Noted | At the time of this inspection this well was shut in with a lockout tag out in place as of 9-13-17 for undetermined reasons. The wellhead assembly all fittings and flow lines were tested for gas. Results of this testing was no gas was detected on the wellhead assembly or the well area. |
2748886 | Primary Facility | 2018-07-05 | Routine/Complete Inspection | No Violations Noted | The DEP conducted a routine inspection of the Marshlands Play-Paul 906 pad located in Westbranch Township, Potter County. The weather is 76°, mostly cloudy, humidity 86%, winds S at 8 mph. No activity was observed onsite. This site has had interim restoration completed. The pad size has been shrunken down and vegetation is growing. PCSM BMP's were installed in April 2016. Due to recent heavy rains standing water was observed on the pad surface. No violations were noted. I departed the site at 1215 hrs. |
2773880 | Primary Facility | 2018-09-12 | Routine/Complete Inspection | No Violations Noted | At the time of this inspection this well was not producing. The valves on the 2" production line leaving the wellhead assembly were in the shut position. A gauge on the production line showed 0 psi (pounds per square inch). Four (4) more valves on the production line going into the production equipment on site all showed 0 psi. also. No violations were noted at this inspection. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1967123 | 609219 | 04/20/2011 | 2011-04-20 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | |
1967123 | 609220 | 04/20/2011 | 2011-04-20 | 102.4NOPLAN - No E&S plan developed, plan not on site | Administrative | 102.4(b)(8) |
1967123 | 609221 | 04/20/2011 | 2011-04-20 | 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. | Administrative | 78.56(a) |
1967123 | 609222 | 04/20/2011 | 2011-04-20 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety | |
1967123 | 609223 | 04/20/2011 | 2011-04-20 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety |
For data sources see[8]