If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-105-21697 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.864158,"lon":-77.682781,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Potter | |
Municipality: Hector Township | |
Operator Name: TRIANA ENERGY LLC | |
Well Pad ID: 149474 | |
Farm/Lease Name: TRIANA YOUNG PAD A 2H | |
License Status: INACTIVE | |
Spud Date: 2010-09-02 | |
Permit Date: 2010-08-02 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.864158 | |
Longitude: -77.682781 |
Date | Event |
---|---|
2010-08-02 | New Permit Application |
2010-09-02 | Performed Spud Operation |
2011-08-09 | Drilling Completion |
2019-02-25 | Inactive Well Request Granted |
2019-03-12 | Deviated |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | TRIANA ENERGY LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | TRIANA ENERGY LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | TRIANA ENERGY LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | TRIANA ENERGY LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | TRIANA ENERGY LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | TRIANA ENERGY LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | TRIANA ENERGY LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | TRIANA ENERGY LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2019 | TRIANA ENERGY LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2010 | TRIANA ENERGY LLC | Drilling Fluid Waste | 747.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0102784 |
2010 | TRIANA ENERGY LLC | Drill Cuttings | 992.00 Tons | LANDFILL | 100361 |
2011 | TRIANA ENERGY LLC | Drill Cuttings | 747.00 Tons | LANDFILL | 100361 |
2011 | TRIANA ENERGY LLC | Drilling Fluid Waste | 71.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | TRIANA ENERGY LLC | Drill Cuttings | 45.00 Tons | LANDFILL | 101397 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1913040 | Primary Facility | 2010-09-15 | Drilling/Alteration | No Violations Noted | |
2011393 | Primary Facility | 2011-10-12 | Routine/Complete Inspection | No Violations Noted | On Oct. 12, 2011 a routine inspection was conducted at the Triana Young Pad A well site. The site ID sign, E&S plan, E&S controls and perimeter of the site were observed. The access road and associated controls were installed and well maintained. The freshwater impoundment was installed and partially fenced. The pad surface was constructed and partially lined. The perimeter BMPs were installed and maintained. All slopes were stabilized. No violations were cited during this inspection. - MRN |
2062317 | Primary Facility | 2012-04-25 | Routine/Complete Inspection | No Violations Noted | |
2182177 | Primary Facility | 2013-07-10 | Routine/Partial Inspection | No Violations Noted | site stabilized, no puddles screened exhibited elevated conductance, no issues noted |
2464349 | Primary Facility | 2016-03-08 | Routine/Complete Inspection | No Violations Noted | The pad size measures ~300’x 350’. The main liner is still visible, along with smaller pieces of liner collecting rainwater around the perimeter of the pad. Puddles were observed on the east and west corners of the pad with conductivity measuring ~250 µs/cm. Three wells were visible on the pad. Each well/cellar has been covered by a large steel plate. The cellars appeared full of water. No well ID tags were visible. Bubbling was observed in the cellars of both the middle and eastern wells on the pad. The OGI inspector supervisor was notified. The outslopes of the pad surface appear stable, mostly rocky with patches of vegetation. Silt sock was observed around the toe of the slope.
An application to terminate a portion of the ESCGP-1 permit and re-permit the site under an ESCGP-2 was received by the NCRO on 9/28/15. This site is now permitted under an ESCGP-2, permit# ESX10-105-0013(02) No violations are issued at this time. Please contact me with any questions. I departed the site @ 1330. |
2618187 | Primary Facility | 2017-07-19 | Routine/Complete Inspection | Violation(s) Noted | On 7/19/17 at 1230 hrs I conducted an inspection at the Triana Young Pad A well site. No one was present during my inspection. It was mostly sunny and 83 degrees F.
The site consists of a well pad, impoundment and access road. It was originally permitted by an ESCGP-1 on 7/30/10; the permit was amended on 11/5/10 for the construction of the impoundment. On 12/14/15, the permit was amended again upon issuance of an ESCGP-2. The freshwater impoundment is located along the access road, before the well pad. The impoundment is protected with a fence, had adequate freeboard and no holes were observed in the liner (Photo #4). The 2H, 4H and 6H wells were drilled in 2011 and placed on inactive status on 1/16/14 (Photo #1). No new well permits have been issued for the location. The cellars were filled with water and bubbling was noted around the 2H and 6H wellheads. This information was passed along to the Oil and Gas Inspector Supervisor. The wells are connected to a poly tank, which appeared to contain a minimal |
2627436 | Primary Facility | 2017-08-17 | Compliance Evaluation | No Violations Noted | On 8/17/17 at 0914 hrs I conducted an inspection at the Triana Young Pad A well site. No one was present during my inspection. It was mostly sunny and 62 degrees F.
The purpose of the inspection was to follow up on violations cited during the 7/19/17 inspection. Documentation of routine E&S inspections and a copy of the ESCGP-2 were not found in the site mailbox during the 7/19/17 inspection. Triana provided copies of the routine E&S inspections upon request, demonstrating that they are being completed. The violation was resolved upon receipt of the inspection documentation. In addition, old permits and paperwork were removed from the site mailbox and replaced with copies of the E&S inspections and the ESCGP-2. A lock was placed on the mailbox to prevent theft of the contents. It was also noted during the last inspection that the well site did not appear to be restored and post construction stormwater management (PCSM) BMPs installed. In response, Triana's consultant provided a copy of the PCSM plan that |
2628808 | Primary Facility | 2017-08-24 | Administrative/File Review | No Violations Noted | On 8/24/17 I reviewed and acknowledged the Triana Young Pad A Well Site Restoration Report (WSRR). The report was submitted electronically on 8/22/17.
Site conditions were verified during inspections conducted on 7/19/17 and 8/17/17; the associated inspection reports document that post construction stormwater management practices are installed and the site is permanently stabilized. No violations are cited in association with this administrative inspection. TLT |
2640182 | Primary Facility | 2017-08-29 | Routine/Complete Inspection | No Violations Noted | This wells status is Regulatory Inactive Status at the time of this inspection. There were no company reps at this inspection. The well pad and well area were neat and clean. This well is vented to a small tank. Being vented is the 9 5/8" x 5 1/2" |
2838161 | Primary Facility | 2019-02-04 | Routine/Complete Inspection | No Violations Noted | At the time of this inspection this wells status was Regulatory Inactive Status. This inspection is for a status extension. At the time of this inspection this well has been drilled to total depth in 2011 but was not completed. This wells conductor, surface casing, intermediate and production strings (casings) are all vented together ( commingled) and are vented to a poly tank at the end of the row of wells. This poly tank has o vent and the vent was tested for combustible gas with an Altair 5 X Multi - Gas Meter that was calibrated on 2-4-19. The results of this testing was 100% LEL (lower explosion limit) and 45% METHANE. No violations were noted at this inspection. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2618187 | 792315 | 2017-07-19 | 2017-08-17 | 78a65(a)1 | Environmental Health & Safety | Triana did not restore the Young Pad A well site within 9 months of completion of drilling the last permitted well. |
2618187 | 792316 | 2017-07-19 | 2017-08-02 | 102.4(b)8 | Administrative | Routine E&S inspections were not conducted as required. |
2618187 | 792317 | 2017-07-19 | 2017-08-17 | OGA3216(A) | Environmental Health & Safety | Triana failed to restore the Young Pad A well site. |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
792315 | 356589 | NOV - Notice of Violation | 2017-08-17 | ||||
792316 | 356589 | NOV - Notice of Violation | 2017-08-17 | ||||
792317 | 356589 | NOV - Notice of Violation | 2017-08-17 |
For data sources see[7]