{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.592177,"lon":-77.968112,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Potter | |
Municipality: Sylvania Township | |
Operator Name: PA GEN ENERGY CO LLC | |
Well Pad ID: 149059 | |
Farm/Lease Name: PINE HILL SYLVANIA, PAD B 2740 | |
License Status: | |
Spud Date: | |
Permit Date: 2018-04-18 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: Yes | |
Latitude: 41.592177 | |
Longitude: -77.968112 |
Date | Event |
---|---|
2018-04-18 | New Permit Application |
2018-05-30 | Performed Spud Operation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2018-10-15 | 2018-10-21 | 11,985 | 11,486,000 | 11,438,200 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | SAND-PREMIUM WHITE-40/70, BULK | Halliburton | Proppant | Listed Below | ||||
OptiKleen-WF(TM) | Halliburton | Concentrate | Listed Below | |||||
Brine Water | PGE | Base Fluid | Listed Below | |||||
Fresh Water | PGE | Base Fluid | Listed Below | |||||
SAND-COMMON WHITE-100 MESH, SSA-2, BULK (100003676) | Halliburton | Proppant | Listed Below | |||||
FIGHTR EC-3 | Halliburton | Friction Reducer | Listed Below | |||||
HYDROCHLORIC ACID | Halliburton | Solvent | Listed Below | |||||
HAI-OS ACID INHIBITOR | Halliburton | Corrosion Inhibitor | Listed Below | |||||
Crystalline silica, quartz | 14808-60-7 | 100 | 9.46564 | 10,140,100.0 | ||||
Fatty acids, tall oil | Proprietary | 30 | 0.00005188 | 56 | ||||
Ethoxylated alcohols | Proprietary | 30 | 0.00007866 | 85 | ||||
Sodium perborate tetrahydrate | 10486-00-7 | 100 | 0.0082917 | 8883 | ||||
Ethylene glycol | 107-21-1 | 60 | 0.0131929 | 14133 | ||||
Sodium polyacrylate | 9003-04-7 | 1 | 0.000219881 | 236 | ||||
Methanol | 67-56-1 | 100 | 0.000668088 | 717 | ||||
Glutaraldehyde | 111-30-8 | 30 | 0.00615114 | 6590 | ||||
Hydrochloric acid | 7647-01-0 | 7.5 | 0.0721889 | 77332.5 | ||||
Phosphoric acid | 7664-38-2 | 0.1 | 0.00002050 | 22 | ||||
Propargyl alcohol | 107-19-7 | 10 | 0.00004407 | 48 | ||||
Olefins | Proprietary | 5 | 0.00002075 | 24 | ||||
Acrylic acid | 79-10-7 | 0.01 | 0.00000220 | 3 | ||||
Water | 7732-18-5 | 100 | 1.04554 | 1,120,040.0 | ||||
Telmer | Proprietary | 10 | 0.00219881 | 2356 | ||||
Water | 7732-18-5 | 100 | 0.0787858 | 84400 | ||||
Modified thiourea polymer | Proprietary | 30 | 0.000212566 | 229 | ||||
Polyoxyalkylene | Proprietary | 5 | 0.00440117 | 4715 | ||||
Hydrotreated light petroleum distillate | 64742-47-8 | 30 | 0.026407 | 28289 | ||||
Acrylamide polymer | Proprietary | 30 | 0.026407 | 28289 | ||||
Water | 7732-18-5 | 100 | 89.3535 | 95,720,100.0 | ||||
Sobitan, mono-9-octadecenoate, (Z) | 1338-43-8 | 5 | 0.00440117 | 4715 | ||||
Ethanol | 64-17-5 | 1 | 0.000205038 | 220 | ||||
Quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl chlorides |
68424-85-1 | 5 | 0.00102519 | 1099 | ||||
SCALECHEK LP-70 | Halliburton | Scale Inhibitor | Listed Below | |||||
MC B-8614 | Halliburton | Biocide | Listed Below | |||||
FDP-S1296-17 | Halliburton | Corrosion Inhibitor | Listed Below |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2019 | PA GEN ENERGY CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2018 | PA GEN ENERGY CO LLC | Drill Cuttings | 55.77 Tons | LANDFILL | 100955 |
2018 | PA GEN ENERGY CO LLC | Produced Fluid | 4,090.00 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
2018 | PA GEN ENERGY CO LLC | Produced Fluid | 120.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018 | PA GEN ENERGY CO LLC | Synthetic Liner Materials | 93.72 Tons | LANDFILL | 301358 |
2018 | PA GEN ENERGY CO LLC | Other Oil & Gas Wastes | 130.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2018 | PA GEN ENERGY CO LLC | Produced Fluid | 646.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018 | PA GEN ENERGY CO LLC | Produced Fluid | 880.00 Bbl | REUSE (AT WELL PAD) | |
2018 | PA GEN ENERGY CO LLC | Produced Fluid | 1,035.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2018 | PA GEN ENERGY CO LLC | Produced Fluid | 16,809.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | PA GEN ENERGY CO LLC | Other Oil & Gas Wastes | 80.00 Bbl | REUSE (AT WELL PAD) | |
2018 | PA GEN ENERGY CO LLC | Drill Cuttings | 2,923.00 Tons | LANDFILL | 301358 |
2018 | PA GEN ENERGY CO LLC | Other Oil & Gas Wastes | 110.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2018 | PA GEN ENERGY CO LLC | Produced Fluid | 2,515.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2018 | PA GEN ENERGY CO LLC | Produced Fluid | 935.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
2018 | PA GEN ENERGY CO LLC | Produced Fluid | 7,420.00 Bbl | INJECTION DISPOSAL WELL | 34-155-24079 |
2019 | PA GEN ENERGY CO LLC | Other Oil & Gas Wastes | 156.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2019 | PA GEN ENERGY CO LLC | Other Oil & Gas Wastes | 100.00 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2737816 | Primary Facility | 2018-06-05 | Routine/Complete Inspection | No Violations Noted | At the time of this inspection this well was a 20" conductor only. The hole was bored (drilled) to a depth of 240' and 98' of conductor pipe was set in the hole on 6-4-2018. No water was noted during the drilling of this conductor placement. Jon Boardman E&S/Safety manager and Brad Cantwell drilling consultant were present at this inspection. |
2740109 | Primary Facility | 2018-06-05 | Routine/Complete Inspection | Violation(s) Noted | The Department of Environmental Protection conducted a routine inspection of the Pennsylvania General Energy – Pine Hill 2382 (Pine Hill Sylvania Pad B) located in Sylvania Twp., Potter Co. on 6/5/2018 @ 1100 hours. The weather was 65 degrees and overcast.
PGE had set the conductor for the Pine Hill Sylvania, Pad B 2740 well (API#105-21910) on the previous day. Cement was observed at the surface surrounding the conductor pipe. Two existing wells were observed onsite 105-21589 and 105-21590, that are listed as in Regulatory Inactive Status (RIS). John Boardman stated PGE plans to bring a Patterson rig to the site in July to drill the lateral portion of the 2740 well. Waste Management was onsite removing the cuttings, from the top hole portion of the well, that were stockpiled in a waste container adjacent to the well. Onsite PGE representative Cory Dean stated they were in the process of resurfacing the pad. Stone was observed stockpiled along the northern side of the pad. Recent earth disturbance activities |
2745510 | Primary Facility | 2018-06-25 | Routine/Complete Inspection | No Violations Noted | At the time of this inspection this well was conductor only. Conductor is 20" x 98' set in a 240' bore hole. |
2754593 | Primary Facility | 2018-07-23 | Routine/Complete Inspection | No Violations Noted | At the time of this inspection the Patterson triple 583 rig was advancing 12 1/4" pipe at an average of approximately 80' per hour. Depth of pipe was at 2402' at this inspection. No gas encountered . Jerry Nietert drilling consultant was at this inspection as was PGE company rep Zach Firduko(drilling engineer). |
2761834 | Primary Facility | 2018-08-07 | Follow-up Inspection | Viol(s) Noted & Immediately Corrected | The DEP conducted a Follow-Up Inspection of the PGE – Pine Hill 2382 (Pine Hill Sylvania Pad B) located in Sylvania Twp., Potter Co. on 8/7/2018 @1100 hours. The weather was 77° overcast, 71% humidity. Korey Starkey, DEP Env Trainee and Zach Fadurko, PGE were present onsite for the inspection.
The access road, well pad, containment and onsite inspection logs were inspected. The Patterson PeakeRig 83 is currently onsite drilling the Pine Hill 2740 (API#105-21910), a Utica well. At the time of the inspection the rig was at 11,036’. Mr. Fadurko stated drilling is utilizing freshwater from the onsite impoundment along with collected rainwater being stored in tanks onsite. We departed the site at 1300 hours. |
2762312 | Primary Facility | 2018-08-08 | Routine/Complete Inspection | No Violations Noted | At the time of this inspection Brad Cantwell(drilling consultant) was at this inspection. The Patterson 583 Triple Rig and crew were advancing 9 5/8" production casing at an average of 9' per hour at the time of this inspection. At the time of this inspection no measurable gas was noted in drillers/ mud loggers log record. At the time of this inspection Zach Ferduko was also present. No violations were noted at the time of this inspection. |
2823730 | Primary Facility | 2019-01-08 | Routine/Complete Inspection | No Violations Noted | The Department of Environmental Protection conducted a routine inspection of the PGE - Pine Hill 2382 well pad located in Sylvania Twp, Potter Co. on 1/8/2019 @1200 hours. The weather was rain, 38 degrees, winds SSW @8mph. Ice had accumulated on the ground the previous evening.
The Pad B 2740 well appears to be shut-in after PGE flared the well the end of last year. No activity or personnel was observed onsite. The temporary water line from the impoundment appears to still be in place. Puddles on the pad surface were screened for conductivity and found to be in normal range. No violations are noted at this time. I departed the site @1300 hours. |
2825918 | Primary Facility | 2019-01-11 | Routine/Complete Inspection | No Violations Noted | At the time of this inspection the drilling of this well was complete. Drilling was started on 7-19-18 and was finished on 9-14-18. Hydraulic fracturing (stimulation) was started on 10-15-18 with 39 total stages scheduled to be hydraulic fractured. A total of 21 stages were fractured out of the proposed 39 stages on 10-21-18. Flow back of the fractured stages was started on 11-8-18. The well as then flared from 11-12-18 until 12-9-18. There are 18 more stages proposed to finish the stimulation of this well with an undetermined date as to when the stimulation will be completed. A gauge on top of the wellhead assembly that is attached to the frac head assembly was showing 0 psi. No violations were noted at this inspection. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2740109 | 819545 | 2018-06-05 | 2018-08-07 | 102.11(a)1 | Environmental Health & Safety | Person failed to design, implement and maintain E&S BMPs to minimize the potential for accelereated erosion and sedimentation to protect, maintain, reclaim and restore water quality and esisting designated uses |
2740109 | 819546 | 2018-06-05 | 2018-08-07 | 102.4(b)8 | Administrative | E&S plan, inspection reports and monitoring records were not available at hte project sitre during all stages of earth disturbance activity. |
2740109 | 819547 | 2018-06-05 | 2018-08-07 | 102.5(c) | Environmental Health & Safety | A violation of 25 Pa Code 102.5(c) is issued at this time for failure to obtain an E&S Permit under this chapter prior to commencing the earth disturbance activity. |
2761834 | 824794 | 2018-08-07 | 2018-08-07 | 78a64a(b) | Environmental Health & Safety |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
819545 | 364820 | NOV - Notice of Violation | 2018-08-07 | ||||
819546 | 364820 | NOV - Notice of Violation | 2018-08-07 | ||||
819547 | 364820 | NOV - Notice of Violation | 2018-08-07 |