{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.506917,"lon":-76.600547,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Sullivan | |
Municipality: Elkland Township | |
Operator Name: SWN PROD CO LLC | |
Well Pad ID: 147407 | |
Farm/Lease Name: CASTROGIOVANNI UNIT | |
License Status: Plugged and Abandoned | |
Spud Date: 2010-12-12 | |
Permit Date: 2010-06-11 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.506917 | |
Longitude: -76.600547 |
Date | Event |
---|---|
2010-06-11 | New Permit Application |
2010-10-28 | New Permit Application |
2010-12-12 | Performed Spud Operation |
2011-01-06 | Drilling Completion |
2011-01-12 | Drilling Completion |
2011-02-03 | Deviated |
2011-02-03 | Newly Drilled |
2011-02-24 | Perforation |
2011-02-24 | Performed Stimulation |
2011-02-26 | Perforation |
2011-02-26 | Performed Stimulation |
2013-03-20 | Inactive Well Request Granted |
2017-07-15 | Begin Plugging |
2017-11-30 | Finished Plugging |
For data sources see[4]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2011-02-24 | 0 | 0 | 0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | SWN PROD CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | SWN PROD CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | CHIEF OIL & GAS LLC | Drill Cuttings | 927.46 Tons | LANDFILL | 100955 |
2011 | CHIEF OIL & GAS LLC | Drill Cuttings | 52.75 Tons | LANDFILL | 301626 |
2011 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 3,333.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0008451 |
2015 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 120.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2016 | SWN PROD CO LLC | Other Oil & Gas Wastes | 33.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | SWN PROD CO LLC | Other Oil & Gas Wastes | 220.00 Bbl | REUSE (AT WELL PAD) | |
2017 | SWN PROD CO LLC | Produced Fluid | 1,100.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017 | SWN PROD CO LLC | Servicing Fluid | 80.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2017 | SWN PROD CO LLC | Servicing Fluid | 214.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017 | SWN PROD CO LLC | Synthetic Liner Materials | 11.00 Tons | LANDFILL | 101247 |
2017 | SWN PROD CO LLC | Servicing Fluid | 40.00 Bbl | SURFACE IMPOUNDMENT | 826342 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1927539 | Primary Facility | 2010-11-15 | Routine/Complete Inspection | Violation(s) Noted | |
1928629 | Primary Facility | 2010-11-18 | Follow-up Inspection | Violation(s) & Outstanding Violations | |
1939013 | Primary Facility | 2010-12-27 | Follow-up Inspection | No Violations Noted | |
1945373 | Primary Facility | 2010-12-14 | Drilling/Alteration | No Violations Noted | |
1952554 | Primary Facility | 2011-02-25 | Drilling/Alteration | No Violations Noted | started liquid nitro frac, formation would not accept fluid, waiting on wire line truck to re-perforate |
1953470 | Primary Facility | 2011-03-01 | Routine/Complete Inspection | Violation(s) Noted | |
1954332 | Primary Facility | 2011-03-01 | Drilling/Alteration | No Violations Noted | violent bubbling in water filled cellar, upon further inspection revealed emmision from 5 1/2 x 9 5/8 annulus remmnant from nitro frac, disturbance dissapated (frac 1 stg.) |
1963725 | Primary Facility | 2011-04-04 | Follow-up Inspection | No Violations Noted | |
1966451 | Primary Facility | 2011-04-18 | Drilling/Alteration | Pending | bubbling in filled pit mousehole not filled |
1972121 | Primary Facility | 2011-05-09 | Routine/Partial Inspection | Violation(s) Noted | |
1978151 | Primary Facility | 2011-06-01 | Routine/Partial Inspection | No Violations Noted | |
1979312 | Primary Facility | 2011-06-08 | Routine/Complete Inspection | No Violations Noted | well tag says 1 not 1H |
1995524 | Primary Facility | 2011-08-09 | Routine/Complete Inspection | No Violations Noted | |
2032634 | Primary Facility | 2012-01-09 | Routine/Complete Inspection | No Violations Noted | |
2067106 | Primary Facility | 2012-05-09 | Routine/Complete Inspection | No Violations Noted | |
2142210 | Primary Facility | 2013-02-21 | Routine/Complete Inspection | No Violations Noted | |
2240952 | Primary Facility | 2014-01-29 | Routine/Partial Inspection | No Violations Noted | |
2272248 | Primary Facility | 2014-05-17 | Routine/Complete Inspection | No Violations Noted | |
2426798 | Primary Facility | 2015-11-12 | Routine/Complete Inspection | No Violations Noted | Arrived at 15:27. This well was transferred from Chief Oil & Gas LLC to SWN Production Company LLC on 10-14-15. The site ID sign reflected the change. |
2462549 | Primary Facility | 2016-03-08 | Drilling/Alteration | No Violations Noted | Weather: warm and sunny. The 1H was the only well on the pad. It was not in production. The 9-5/8” x 5-1/2” was the only annular vent, it was shut-in at the time of my inspection although plumbing to a vented polytank was on site.
On 3/7/16, observed bubbling in the well cellar. Contacted Jason Petlock and arranged to meet with staff on 3/8/16 to investigate. Arrived at 13:30, Mountain Energy vac truck was on site. Met with Mike Hronich (SWN). As cellar was vacc’ed out we could see that the bubbles on both sides were coming from leaking valves on the 9-5/8” x 5-1/2” casing vent, which was shut-in. Pressure on the vent was 170.7 psi, it blew down in a few seconds. The annulus was shut-in when I left the location. On 3/9/16 I contacted Afton Sterling (SWN) to discuss the rationale for allowing the casing to vent. She agreed to do this. No violations were noted at the time of my inspection. Left location @ 14:45. |
2471518 | Primary Facility | 2016-04-05 | Routine/Complete Inspection | No Violations Noted | Routine inspection conducted to assess site conditions. No Southwestern representatives were present.
Overall vegetative cover on site is greater than 70 percent. Temporary erosion and sediment control BMPs have been removed. No evidence of accelerated erosion or sedimentation was observed. The drilled well on site is not in production, and no active drilling permits exist for the site. The Erosion and Sediment Control General Permit (ESCGP) was set to expire on 10/03/2015. On 10/1/2015, the Department issued a six-month extension which extended the permit expiration until 04/01/2016. To maintain compliance with the Department's regulations pertaining to site restoration (58 Pa. C.S. § 3216), a 2-year restoration extension should be requested for this site. No violations were cited during this inspection. |
2534870 | Primary Facility | 2016-11-02 | Routine/Complete Inspection | No Violations Noted | Weather: warm and sunny. Arrived at 11:10. The 1H was the only well on the pad. It was locked, tagged, and not in production. Cellar was filled with water, no bubbles. The 9-5/8” x 5-1/2” was the only annular vent, it plumbing to a vented 550-gal polytank was on site. The vent pipe entered the polytank at the base, below the water line. Bubbles were emitted approximately for a few seconds, once every 5 seconds. The concentration of combustible gas in the tank was 16%/volume (Altair 5X gas meter calibrated 11/2/16).
There were no violations noted at the time of this inspection. Left location @ 10:45. |
2544499 | Primary Facility | 2016-12-13 | Routine/Complete Inspection | No Violations Noted | Routine inspection conducted to assess site conditions. No Southwestern representatives were present.
Overall vegetative cover on site is greater than 70 percent. Temporary erosion and sediment control BMPs have been removed. No evidence of accelerated erosion or sedimentation was observed. The Erosion and Sediment Control General Permit (ESCGP) was expired on 04/01/2016. Currently, no active well permits exist for the site. To maintain compliance with the Department's regulations pertaining to site restoration (58 Pa. C.S. § 3216), a 2-year restoration extension should be requested for this site. Southwestern is reminded that a current ESCGP is required to conduct site restortation activities. No violations were cited during this inspection. |
2618893 | Primary Facility | 2017-07-25 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Inspection of SWN’s Castrogiovanni 1H conducted July 25, 2017 at approximately 1 pm. Crew was off location, well was shut in with master valve on b section. CIBP has been set in the 5 ½” production casing. Analog gauge showed ~650 PSI on the prod. csg.. Gauge for backside of production casing read 0 PSI, may be isolated at needle valve. I called the operator, they called back and confirmed the needle valve is just shut on the backside and the production casing gauge was just trapped pressure at the wellhead; production csg. is dead after setting CIBP. The rig plans to return after monitoring pressures on this well and finish the P&A |
2620130 | Primary Facility | 2017-07-28 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Inspection of SWN’s Castrogiovanni 1H conducted July 28, 2017 at approximately 12 pm. Crew was off location, well was shut in with master valve on b section. CIBP has previously been set in the 5 ½” production casing. Analog gauge showed 0 PSI on the prod. csg.. Gauge for backside of production casing read 0 PSI (isolated at needle valve.) The cellar was full of water with some minor bubbling noted, it is unclear where it was coming from. |
2627854 | Primary Facility | 2017-08-16 | Routine/Complete Inspection | No Violations Noted | Inspection of SWN’s Castrogiovanni 1H conducted July 16, 2017 at approximately 2:30 pm. No one on location, well was shut in with master valve on b section. CIBP has previously been set in the 5 ½” production casing. Analog gauge showed 0 PSI on the prod. csg.. Gauge for backside of production casing read 0 PSI (isolated at needle valve.) I could now see the source of the bubbling was from a fitting on the well wellhead for the backside of production casing. |
2629551 | Primary Facility | 2017-08-28 | Routine/Complete Inspection | No Violations Noted | Well is Shut in with master valve. Crew is expected to return to site to finish P&A. Analog pressure gauges isolated from well. Cellar dry. No obvious issues observed at time of inspection |
2633428 | Primary Facility | 2017-09-07 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Routine Inspection of a well being plugged. Well is shut-in, isolated from gauges. Location vacant. Rig scheduled to return to location to finish P&A. No violations observed. |
2636493 | Primary Facility | 2017-09-15 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Rig back on location fo P&A. CIBP was previously set at 9000'. No pressure on casing upon rig's arrival on location. Rig ran in hole w/ tbg to tag CIBP, reverse circulated well and encountered pressure after pumping 37 bbls. Bled off, gas, pressure built back up. Discussed w/ operator about setting additional CIBP at 8900' assuming first one failed. Rig pulled tbg, currently no pressure on casing. Operator suspects it may have been a trapped gas between first CIBP and wellhead rather than formation pressure, and will decide on setting the additional CIBP and cement or cement on top of first CIBP at this point. Backside of casing still ~290 psi, no significant change |
2638897 | Primary Facility | 2017-09-22 | Routine/Complete Inspection | No Violations Noted | Rig off location. P&A Operations have temporarily ceased following squeeze work behind production casing. Backside of production casing was open and venting to a tank. Checked vented cap w/ Altair 5x gas meter, peaked at 25% gas. No obvious violations were observed. |
2640467 | Primary Facility | 2017-09-27 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Well is shut in at mastervalve on b section. Blanked flange on mastervalve with analog gauge isolated from wellbore, 0 psi. Backside of production casing is open and piped into a vent tank, lid was loose with vented cap on lid, 9% gas detected at vent port on lid. Cellar had water below surface casing and inside the casing, no bubbling. Rig has ceased operations during this P&A to monitor. |
2660838 | Primary Facility | 2017-11-14 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Routine inspection, post-plugging ops. B section and master valve are on well. Cellar is full of water with no bubbling. Backside of production casing was open with 2" iron rigged up to vent away from well. The pipe was partially submerged in water, no bubbling. No gas was detected at the vent, and there was no flow observed. No obvious issues were observed. |
2667839 | Primary Facility | 2017-12-06 | Administrative/File Review | No Violations Noted | December 6, 2017: Certificate of Well Plugging for the Castrogiovanni 1 (113-20005) has been received, reviewed, signed, and sent to file. |
2668561 | Primary Facility | 2017-12-06 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Routine inspection of a plugged well. The well has been plugged, cut, capped, and buried below grade. At the time of inspection, there some standing water above the wells approximate location. No bubbling was observed. I used an altair 5x gas meter to monitor for gas in several spots at the wells surface location. No gas was detected. There were no obvious issues observed. Attached are photos from the inspection in addition to a photo of the marker cap before burial. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1927539 | 599341 | 11/15/2010 | 2010-11-15 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | |
1928629 | 599684 | 11/18/2010 | 2010-11-18 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | |
1928629 | 599685 | 11/18/2010 | 2010-11-18 | 401 CSL - Discharge of pollultional material to waters of Commonwealth. | Environmental Health & Safety | |
1953470 | 605673 | 03/01/2011 | 2011-03-01 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | |
1953470 | 605674 | 03/01/2011 | 2011-03-01 | 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation. | Administrative | |
1953470 | 605675 | 03/01/2011 | 2011-03-01 | 402POTNLPOLL - There is a potential for polluting substance(s) reaching Waters of the Commonwealth and may require a permit. | Environmental Health & Safety | |
1972121 | 610727 | 05/09/2011 | 2011-05-09 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | Eroded sediment trap with sediment discharge outside LOD |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
605673 | 268408 | NOV - Notice of Violation | Comply/Closed | 2011-08-09 | |||
605674 | 268408 | NOV - Notice of Violation | Comply/Closed | 2011-08-09 | |||
605675 | 268408 | NOV - Notice of Violation | Comply/Closed | 2011-08-09 |