Well Details

Well ID: 37-113-20010
Loading map...
Country: United States
State: Pennsylvania
County: Sullivan
Municipality: Elkland Township
Operator Name: CHIEF OIL & GAS LLC
Well Pad ID: 146347
Farm/Lease Name: MCCARTY UNIT 1
License Status: INACTIVE
Spud Date: 2010-07-28
Permit Date: 2010-07-20
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: No
Latitude: 41.529436
Longitude: -76.683178

For data sources see[1][2][3]

Well History

Date Event
2010-07-20 New Permit Application
2010-07-26 Performed Spud Operation
2010-08-26 Drilling Completion
2010-11-02 New Permit Application
2010-11-30 DEVIATED
2011-01-21 NEWLY DRILLED
2011-02-28 Perforation
2013-03-20 Inactive Well Request Granted
2013-06-24 Perforation
2013-10-24 Drilling Completion
2015-02-04 REWORKED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-09-04 2013-09-21 8,207 6,032,960

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Hydrochloric Acid 10-30% Halliburton Acid Hydrochloric Acid 7647-01-0 30 0.11 0
Water Provided by Customer Base Fluid Fresh Water 0000-00-0 100 99.83 0
FR-66 Halliburton Friction Reducer Hydrotreated Light Petroleum Distillate 64742-47-8 30 0.03 0
MCB-8614 MULTI-CHEM BIOCIDE GLUTARALDEHYDE 111-30-8 30 0.02 0
ALKYL (C12-16) DIMETHYLBENZXYLAMMONIUM CHLORIDE 68424-85-1 5 0.003 0
MCS-2510T MULTI-CHEM Scale Inhibitor ETHYLENE GLYCOL 107-21-1 60 0.005 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2011 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2012 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2013 CHIEF OIL & GAS LLC 141,163.00 67 0.00 0 0.00 0
2014 CHIEF OIL & GAS LLC 569,528.00 362 0.00 0 0.00 0
2015 CHIEF OIL & GAS LLC 355,942.09 362 0.00 0 0.00 0
2016 CHIEF OIL & GAS LLC 312,758.59 364 0.00 0 0.00 0
2017 CHIEF OIL & GAS LLC 292,467.42 365 0.00 0 0.00 0
2018 CHIEF OIL & GAS LLC 150,405.56 360 0.00 0 0.00 0
2019 CHIEF OIL & GAS LLC 90,471.91 278 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 CHIEF OIL & GAS LLC Produced Fluid 130.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2010 CHIEF OIL & GAS LLC Drilling Fluid Waste 1,049.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2010 CHIEF OIL & GAS LLC Drilling Fluid Waste 1,140.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0008451
2010 CHIEF OIL & GAS LLC Fracing Fluid Waste 2,080.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2011 CHIEF OIL & GAS LLC Drill Cuttings 90.65 Tons LANDFILL 301626
2011 CHIEF OIL & GAS LLC Drilling Fluid Waste 100.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2011 CHIEF OIL & GAS LLC Fracing Fluid Waste 368.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0008451
2013 CHIEF OIL & GAS LLC Produced Fluid 110.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2013 CHIEF OIL & GAS LLC Fracturing Fluid Waste 11.95 Tons RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC006
2013 CHIEF OIL & GAS LLC Fracing Fluid Waste 19.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC006
2013 CHIEF OIL & GAS LLC Produced Fluid 4,298.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHIEF OIL & GAS LLC Fracing Fluid Waste 7,394.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHIEF OIL & GAS LLC Produced Fluid 4,391.81 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHIEF OIL & GAS LLC Produced Fluid 3,537.01 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHIEF OIL & GAS LLC Produced Fluid 2,607.51 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHIEF OIL & GAS LLC Produced Fluid 1,878.25 Bbl REUSE (AT WELL PAD)
2017 CHIEF OIL & GAS LLC Produced Fluid 296.28 Bbl REUSE OTHER THAN ROAD SPREADING
2018 CHIEF OIL & GAS LLC Produced Fluid 870.75 Bbl REUSE (AT WELL PAD)
2019 CHIEF OIL & GAS LLC Produced Fluid 741.49 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1902280 Primary Facility 2010-07-29 Drilling/Alteration No Violations Noted
1945303 Primary Facility 2010-12-14 Drilling/Alteration No Violations Noted
1949603 Primary Facility 2011-02-11 Drilling/Alteration No Violations Noted
1954312 Primary Facility 2011-03-01 Drilling/Alteration No Violations Noted atteempt at nitro foam frac, created pressures too high during treatment to remain within safe paramiters, upto 9000# , shut down nitro and will return at later date with conventional hydro-frac, treated broke stage with sand an water before leaving
1963890 Primary Facility 2011-04-06 Drilling/Alteration No Violations Noted well shut in after nitro frac need to have gauge on 9 5/8' x 5 1/2' annulus
1965459 Primary Facility 2011-04-13 Routine/Complete Inspection Violation(s) Noted
1971999 Primary Facility 2011-05-09 Routine/Partial Inspection No Violations Noted
1979328 Primary Facility 2011-06-08 Routine/Complete Inspection No Violations Noted has been fraced, line out to tank as requested by Kevin Costello, site looks good
2050926 Primary Facility 2012-03-15 Routine/Complete Inspection No Violations Noted
2140680 Primary Facility 2013-02-14 Routine/Complete Inspection No Violations Noted
2189335 Primary Facility 2013-08-05 Routine/Complete Inspection No Violations Noted
2205298 Primary Facility 2013-09-17 Routine/Complete Inspection No Violations Noted
2217886 Primary Facility 2013-10-29 Incident- Response to Accident or Event Violation(s) Noted Flowback discovered under liner on 10/24/13. Called in on 10/25/13. Volume uncertain. Viols closed 3/24/2014 with approval of Remedial Activity Report
2227053 Primary Facility 2013-11-22 Incident- Response to Accident or Event Outstanding Violations - No Viols Req'd Gas buster not yet moved so pad beneath not evaluated, Elevated conductivity puddle adjacent.
2255163 Primary Facility 2014-03-19 Routine/Complete Inspection No Violations Noted
2481080 Primary Facility 2016-05-04 Routine/Complete Inspection No Violations Noted The site currently has >70% coverage of perennial vegetation and temporary erosion and sediment control BMPs have been removed. No evidence of accelerated erosion or sedimentation was observed.

The electrical conductance of puddles was not screened due to the absence of puddles.

Because the site is under 5 acres in size, no Erosion and Sediment Control General Permit exists for this site. No current well permits exist. Chief has indicated that it plans to partially restore the well pad by spring 2019. In order to remain in compliance with the Department's regulations regarding site restoration (Title 58 Pa. C.S. § 3216), Chief should obtain a new drilling permit or request a 2-year extension of time for site restoration.

No violations were cited during this inspection.

2562284 Primary Facility 2017-02-16 Routine/Complete Inspection No Violations Noted No violations cited.
2589676 Primary Facility 2017-05-03 Routine/Complete Inspection No Violations Noted One well in production phase. One separator within containment. One suction engine on location. No leaks detected from production equipment. Site stabile. No violations.
2650789 Primary Facility 2017-10-23 Routine/Complete Inspection No Violations Noted Arrived at 14:34. Weather: overcast. 1 producing well onsite. Cellar gravel-filled. One annular vent, open plumbed to 550-galllon polytank (no combustible gas detected at tank vent). Well on compression with artifical lift. 350 psi(0-3000psi analog) at top gauge.
2784680 Primary Facility 2018-10-03 Routine/Complete Inspection No Violations Noted Arrived onsite for a routine inspection. Previous rainfall formed a few puddles on the pad. One of these puddles had a conductivity of 138.5 µS/cm.

There is 1 properly tagged Marcellus well staged for production. There is 1 GPU, 1 compressor, and 2 produced water tanks onsite and in secondary containment. Water in GPU and produced water tank secondary containment had conductivities of 43.8 µS/cm and 119.4 µS/cm respectively.

The pad has been reduced in size and is well vegetated. PCSM BMPs were present and appeared to be functioning as designed. E&S inspections are being conducted and the log was present onsite. All other pertinent paperwork was also available in the mailbox.

No violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1965459 608791 04/13/2011 2011-04-13 401 CSL - Discharge of pollultional material to waters of Commonwealth. Environmental Health & Safety
2217886 681680 10/29/2013 2013-10-29 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. Environmental Health & Safety Flowback iron appears to have leaked at joint, got under liner, accumulated and spread over an area some 50 x 75' in the northeastern quadrant of the pad.
2217886 681681 10/29/2013 2013-10-29 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety Brine discharged onto pad

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
681680 304042 NOV - Notice of Violation Comply/Closed 2014-03-24
681681 304042 NOV - Notice of Violation Comply/Closed 2014-03-24