37-113-20025

Well Details

Well ID: 37-113-20025
Loading map...
Country: United States
State: Pennsylvania
County: Sullivan
Municipality: Davidson Township
Operator Name: EXCO RESOURCES PA LLC
Well Pad ID: 146905
Farm/Lease Name: MARQUARDT UNIT 1H
License Status: PLUGGED & ABANDONED
Spud Date: 2010-09-29
Permit Date: 2010-08-13
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.352786
Longitude: -76.572981

For data sources see[1][2][3]

Well History

Date Event
2010-08-13 New Permit Application
2010-09-13 Performed Spud Operation
2010-10-16 Drilling Completion
2010-11-30 Perforation
2011-04-08 DEVIATED
2015-09-18 Drilling Completion
2015-11-13 FULLY PLUGGED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-10-18 2012-10-18 9,390 3,732,873

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 DAP-925 Calfrac Well Services Acid Corrosion Inhibitor
Hydrochloric Acid Calfrac Well Services Clean Perforations Quartz 14808-60-7 100.00 16.06
Methanol 67-56-1 60.00 0.00649000
Carbonic acid calcium salt (1:1) 471-34-1 1.00 0.03
Hydrochloric acid 7647-01-0 37.00 0.30
Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.02
Propargyl Alcohol 10.00 0.00013000
Biotite 1302-27-8 0.10 0.00276000
Polyacrylamide polymer 40.00 0.03
Organic phosphonate 1 30.00 0.00568000
Illite 12173-60-3 1.00 0.00345000
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 40.00 0.01
Olefin 5.00 0.00007000
Oxyalkylated polyamine 5.00 0.00095000
Citric acid 77-92-9 60.00 0.00283000
Polyoxyalkylenes 30.00 0.00040000
Formalin 50-00-0 0.10 0.00003000
Organic phosphonate 2 10.00 0.00189000
Amine salt 5.00 0.00095000
Fatty acids 30.00 0.00040000
Nonionic surfactant 5.00 0.00407000
Ammonium chloride 12125-02-9 10.00 0.00114000
Sodium chloride 7647-14-5 1.00 0.00001000
Polyethylene glycol 25322-68-3 70.00 0.01
Apatite 64476-38-6 0.10 0.00276000
Ilmenite (FeTiO3), conc. 98072-94-7 0.10 0.00128000
Polyoxyalkylenes surfactant 5.00 0.00407000
Goethite 1310-14-1 0.10 0.00573000
Acetic acid 64-19-7 1.00 0.00019000
Thiourea polymer 68527-49-1 30.00 0.00040000
Water BaseFluid/Mix Water Water 7732-18-5 100.00 83.51
DAP-901 Calfrac Well Services Scale Inhibitor
DAP-103 Calfrac Well Services Iron Control
DWP-612 Calfrac Well Services Friction Reducer
DWP-944 Calfrac Well Services Biocide
Sand (Proppant) Calfrac Well Services Propping Agent

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2011 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2012 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2013 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2014 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2015 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 EXCO RESOURCES PA LLC Fracing Fluid Waste 6,738.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2011 EXCO RESOURCES PA LLC Drilling Fluid Waste 704.31 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 EXCO RESOURCES PA LLC Fracing Fluid Waste 10,425.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 EXCO RESOURCES PA LLC Fracturing Fluid Waste 32.25 Tons LANDFILL 301358
2014 EXCO RESOURCES PA LLC Fracing Fluid Waste 12,445.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EXCO RESOURCES PA LLC Produced Fluid 220.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 EXCO RESOURCES PA LLC Fracing Fluid Waste 1,980.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2015 EXCO RESOURCES PA LLC Produced Fluid 499.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC009

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1939434 Primary Facility 2010-12-28 Routine/Complete Inspection Violation(s) Noted
1950092 Primary Facility 2011-02-15 Follow-up Inspection Violation(s) Noted
1959108 Primary Facility 2011-03-16 Follow-up Inspection Outstanding Violations - Viols Req'd
1980356 Primary Facility 2011-06-14 Routine/Complete Inspection No Violations Noted no permit # on sign, cellar full of water - no bubbles, 750 psi on prod.
1984377 Primary Facility 2011-06-29 Routine/Complete Inspection No Violations Noted
1993482 Primary Facility 2011-08-04 Routine/Complete Inspection No Violations Noted Signs changed to EXCO.
2000051 Primary Facility 2011-08-30 Follow-up Inspection No Violations Noted Inspection to look at previous violations. Permit number and well tag lacking.
2031134 Primary Facility 2011-12-30 Routine/Complete Inspection No Violations Noted
2059038 Primary Facility 2012-04-12 Routine/Complete Inspection No Violations Noted
2062464 Primary Facility 2012-04-25 Routine/Complete Inspection No Violations Noted
2112824 Primary Facility 2012-10-26 Routine/Partial Inspection No Violations Noted
2117170 Primary Facility 2012-11-20 Routine/Complete Inspection No Violations Noted
2124768 Primary Facility 2012-12-18 Routine/Complete Inspection No Violations Noted
2144079 Primary Facility 2013-02-28 Routine/Complete Inspection No Violations Noted
2187255 Primary Facility 2013-07-24 Routine/Complete Inspection No Violations Noted
2250840 Primary Facility 2014-03-04 Incident- Response to Accident or Event Pending Spill reported 2/27/14. Several barrels flowback blew out of flare stack. Little sign of spill on ground. Results pending site characterization report.
2253420 Primary Facility 2014-02-27 Follow-up Inspection No Violations Noted
2272303 Primary Facility 2014-05-17 Routine/Complete Inspection No Violations Noted
2322936 Primary Facility 2014-11-19 Administrative/File Review No Violations Noted The Department has reviewed the Site Characterization Report for the response to the flowback fluid release which occurred at the Marquardt well pad, Davidson Township, Sullivan County on February 27, 2014. The report for the release was prepared by Envirotrac Environmental Services and received by the Department on September 2, 2014.
2371849 Primary Facility 2015-05-20 Routine/Complete Inspection No Violations Noted Arrived @ 09:00. Cloudy, cold, windy. There was one well, locked and chained, not in production. Cellar: gravel-filled, stained. 1 visible annular vent, open, 0% methane. Water tank parts on location. Recommend cellar be cleaned out. Left location 10:00.
2406259 Primary Facility 2015-09-09 Complaint Inspection Viol(s) Noted & Immediately Corrected Approx 15 gallons cellar water escaped containment. Affect pad area was excavated.
2407776 Primary Facility 2015-09-16 Plugging(Includes Plugged/Mined Through) No Violations Noted Arrived @ 11:30, Weather was sunny and warm. Met with company man Jerry Jones. Site mobilization for this plugging began on 9/14/15. At the time of my inspection, Team workover rig and crew and Cased Hole Solutions truck and crew were onsite. Tubing had been pulled and a Cast Iron Bridge plug had been set @ 8152’ in the middle of a joint. The crew was mixing up 5-gallon buckets of NeoSlurry Class H cement (17 ppg). This was being poured down into the baler to form a 50’ plug. Discussed progress so far with Jones who noted that when the well bore was full of fluid and no gas had been encountered thus far. Discussed plans to cut casing tomorrow morning (9/17/15). Left location @ 12:20.
2407786 Primary Facility 2015-09-17 Plugging(Includes Plugged/Mined Through) No Violations Noted Arrived @ 09:10, Weather was sunny and warm. Met with company man Jerry Jones. At the time of my inspection, Team workover rig and crew, Cased Hole Solutions truck and crew, and Express staff were onsite. Casing had just been cut @ 3468’. Workers removed the well head, the rig speared into the casing and pulled. The casing came free on 180,000 lbs. Portable 5-1/2” casing tongs were rigged up handle the 5-1/2 casing (approximately 85 joints to pull). Cased Hole Solutions left the location. EXCO safety man Tom Livingstone arrived. Once the casing was free, it took 120,000 lbs to lift the second joint. Plan for the rest of the day was to pull casing, and run in tubing in preparation for setting cement plugs on Friday. Left location @ 11:30.
2408569 Primary Facility 2015-09-28 Plugging(Includes Plugged/Mined Through) No Violations Noted Arrived @ 13:25. Well has been plugged and the well head has been buried with a candy cane vent. Field monitoring with an Altair 5X gas meter calibrated on 9/28/15 failed to detect methane. It is worth noting that there were discolored patches in the fill material near the well head. Left location @ 13:45.
2412151 Primary Facility 2015-10-01 Follow-up Inspection No Violations Noted Inspection conducted to follow-up on condition of site after the well was plugged and a release of cellar water that occurred on 09/09/2015. The cellar around the well has been filled in. A crew was on site removing pipeline from the well pad area. Overall vegetative cover on the site is <70%. No signs of accelerated erosion or sedimentation were observed.
2416236 Primary Facility 2015-10-09 Plugging(Includes Plugged/Mined Through) No Violations Noted Arrived @ 14:00. Weather: cold, windy, with rain. Well has been plugged and the well head has been buried with a candy cane vent. Field monitoring with an Altair 5X gas meter calibrated on 9/28/15 failed to detect methane. There appears to be a small land slip on the upslope side of the pad. This well was plugged 3 weeks ago. Plugging appeared to have been successful and there was no detectable expression of combustible gas at the surface. Left location at 15:00.
2495847 Primary Facility 2016-06-24 Routine/Complete Inspection No Violations Noted
2631577 Primary Facility 2017-08-31 Plugging(Includes Plugged/Mined Through) No Violations Noted Routine Inspection of a plugged well. Vent monument in place. No flow or other issues observed.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1939434 602104 12/28/2010 2010-12-28 201H - Failure to properly install the permit number, issued by the department, on a completed well. Administrative
1950092 604868 02/15/2011 2011-02-15 201H - Failure to properly install the permit number, issued by the department, on a completed well. Administrative
1950092 604869 02/15/2011 2011-02-15 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. Administrative
1959108 607073 03/16/2011 2011-03-16 201H - Failure to properly install the permit number, issued by the department, on a completed well. Administrative
1959108 607074 03/16/2011 2011-03-16 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. Administrative
2406259 734455 09/09/2015 2015-09-09 CSL 402(b) - POTENTIAL POLLUTION - Conducting an activity regulated by a permit issued pursuant to Section 402 of The Clean Streams Law to prevent the potential of pollution to waters of the Commonwealth without a permit or contrary to a permit issue Environmental Health & Safety
2406259 734456 09/09/2015 2015-09-09 91.34A - Failure to take all necessary measures to prevent spill. Inadequate diking, potential pollution Environmental Health & Safety

For data sources see[8]