If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-113-20047 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.560681,"lon":-76.614542,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Sullivan | |
Municipality: Elkland Township | |
Operator Name: CHESAPEAKE APPALACHIA LLC | |
Well Pad ID: 149142 | |
Farm/Lease Name: RAIN 5H | |
License Status: INACTIVE | |
Spud Date: 2011-02-12 | |
Permit Date: 2010-09-30 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.560681 | |
Longitude: -76.614542 |
Date | Event |
---|---|
2010-09-30 | New Permit Application |
2011-01-06 | Performed Spud Operation |
2011-04-15 | Drilling Completion |
2011-12-06 | Perforation |
2013-08-29 | Inactive Well Request Granted |
2014-12-19 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-01-06 | 2012-01-06 | 7,792 | 4,797,702 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Biocide - Bactron K 139 | Champion Technologies | Antibacterial Agent | Quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides |
68424-85-1 | 10.00 | 0.00350000 | |
Ethanol | 64-17-5 | 5.00 | 0.00175000 | |||||
Ottawa Sand | Proppant | Quartz | 14808-60-7 | 100.00 | 11.59 | |||
ACID, HYDROCHLORIC, 15 PCT | Weatherford | Acid | Hydrochloric acid | 7647-01-0 | 15.00 | 0.05 | ||
Water | 7732-18-5 | 85.00 | 0.29 | |||||
Fresh Water | Carrier/Base Fluid | 75.03 | ||||||
Recycled Produced Water | Carrier/Base Fluid | 11.58 | ||||||
Scale Inhibitor - Gyptron T-390 | Champion Technologies | Scale Inhibitor | Methanol | 67-56-1 | 10.00 | 0.00113000 | ||
Iron Control - WIC-641L | Weatherford | Iron Control Agent | Citric acid | 77-92-9 | 50.00 | 0.00149000 | ||
100 Mesh Sand | Proppant | Quartz | 14808-60-7 | 100.00 | 1.32 | |||
Inhibitor - WAI-251LC | Weatherford | Corrosion Inhibitor | 1-Octanol | 111-87-5 | 7.00 | 0.00004000 | ||
2-Butoxyethanol | 111-76-2 | 5.00 | 0.00003000 | |||||
N,N-Dimethylformamide | 68-12-2 | 30.00 | 0.00015000 | |||||
Isopropanol | 67-63-0 | 7.00 | 0.00004000 | |||||
Ethylene glycol | 107-21-1 | 40.00 | 0.00020000 | |||||
Proprietary | 13.00 | 0.00007000 | ||||||
1-Decanol | 112-30-1 | 7.00 | 0.00004000 | |||||
WFR-55LA | Weatherford | Friction Reducer | No Hazardous Components | 0.00 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | CHESAPEAKE APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | CHESAPEAKE APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CHESAPEAKE APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | CHESAPEAKE APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | CHESAPEAKE APPALACHIA LLC | 941,984.00 | 154 | 0.00 | 0 | 0.00 | 0 |
2015 | CHESAPEAKE APPALACHIA LLC | 999,341.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CHESAPEAKE APPALACHIA LLC | 530,060.00 | 300 | 0.00 | 0 | 0.00 | 0 |
2017 | CHESAPEAKE APPALACHIA LLC | 332,722.00 | 320 | 0.00 | 0 | 0.00 | 0 |
2018 | CHESAPEAKE APPALACHIA LLC | 265,096.00 | 333 | 0.00 | 0 | 0.00 | 0 |
2019 | CHESAPEAKE APPALACHIA LLC | 224,887.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | CHESAPEAKE APPALACHIA LLC | Drilling Fluid Waste | 7,477.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CHESAPEAKE APPALACHIA LLC | Produced Fluid | 2,108.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CHESAPEAKE APPALACHIA LLC | Fracing Fluid Waste | 165.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CHESAPEAKE APPALACHIA LLC | Fracturing Fluid Waste | 17.00 Tons | LANDFILL | 301626 |
2014 | CHESAPEAKE APPALACHIA LLC | Fracing Fluid Waste | 205.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC008 |
2014 | CHESAPEAKE APPALACHIA LLC | Produced Fluid | 4,047.15 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | CHESAPEAKE APPALACHIA LLC | Produced Fluid | 85.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2015 | CHESAPEAKE APPALACHIA LLC | Produced Fluid | 2,244.10 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CHESAPEAKE APPALACHIA LLC | Other Oil & Gas Wastes | 110.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CHESAPEAKE APPALACHIA LLC | Produced Fluid | 637.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CHESAPEAKE APPALACHIA LLC | Produced Fluid | 145.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2016 | CHESAPEAKE APPALACHIA LLC | Produced Fluid | 212.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2017 | CHESAPEAKE APPALACHIA LLC | Other Oil & Gas Wastes | 51.00 Bbl | REUSE (AT WELL PAD) | |
2018 | CHESAPEAKE APPALACHIA LLC | Produced Fluid | 106.40 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1929677 | Primary Facility | 2010-10-18 | Routine/Complete Inspection | Violation(s) Noted | |
1939161 | Primary Facility | 2010-12-27 | Follow-up Inspection | No Violations Noted | |
1952108 | Primary Facility | 2011-02-18 | Drilling/Alteration | No Violations Noted | |
1952561 | Primary Facility | 2011-02-25 | Drilling/Alteration | Pending | possible gas escape showing in cellar, rig is gone, crews doing prliminary remidiation on location will follow up |
1956430 | Primary Facility | 2011-03-09 | Drilling/Alteration | No Violations Noted | |
1961861 | Primary Facility | 2011-03-30 | Drilling/Alteration | No Violations Noted | lost tools at 6176/270 ' of iron in hole (see acc. diagram) cement back to 5676 kick off 5 degrees on neww curve maintaining parameters of original platt and permit |
1979224 | Primary Facility | 2011-06-09 | Routine/Complete Inspection | No Violations Noted | doing some E&S work - site good |
1991497 | Primary Facility | 2011-07-29 | Routine/Complete Inspection | No Violations Noted | 5 tanks - on containment |
2073980 | Primary Facility | 2012-06-05 | Routine/Complete Inspection | No Violations Noted | |
2147577 | Primary Facility | 2013-03-06 | Routine/Complete Inspection | No Violations Noted | |
2184624 | Primary Facility | 2013-07-17 | Routine/Complete Inspection | No Violations Noted | |
2451602 | Primary Facility | 2016-02-18 | Routine/Complete Inspection | No Violations Noted | Routine inspection conducted to assess general site conditions. No Chesapeake representatives were present.
Temporary erosion and sediment control BMPs have been removed. Overall, the site has >70% vegetative cover. No evidence of accelerated erosion or sedimentation was observed. No staining or other evidence of spills was observed on the pad surface. No puddles were present on the pad at the time of inspection, so electrical conductance was not screened. This well site is due for restoration. However, Chesapeake indicated in its filing dated September 21, 2015, that a restoration extension request would be submitted for this site. At this time, the Department's records do not include an extension request. This request should be filed as soon as possible. No violations were cited during this inspection. |
2540689 | Primary Facility | 2016-12-01 | Routine/Complete Inspection | No Violations Noted | Routine inspection conducted to assess general site conditions. No Chesapeake representatives were present.
Temporary erosion and sediment control BMPs have been removed. Vegetative cover on the site is greater than 70%. No evidence of accelerated erosion or sedimentation was observed. No staining or other evidence of spills was observed on the pad surface. No puddles were present on the pad at the time of inspection, so electrical conductance was not screened. A request for an extention of time for site restoration was filed with the Department on April 22, 2016. To date, the submitted request has not been approved. No violations were cited during this inspection. |
2643938 | Primary Facility | 2017-10-04 | Routine/Complete Inspection | No Violations Noted | Arrived at 12:15: Weather: sunny, very nice. There was 1 producing well on a 3-slot set-up. All of the cellars were filled with water.
Rain 5H 13-3/8" x 9-5/8": open to dump line, 2.83 psi (digital) 9-5/8" x 5-1/2": closed to dump, -0.26 psi (digital 5-1/2": 356.85 psi (digital) Top gauge: 1282 psi ( digital). Left at 12:50. No violations were observed at the time of my inspection. |
2805500 | Primary Facility | 2018-11-20 | Routine/Complete Inspection | No Violations Noted | Arrived onsite for a routine inspection at 09:45; the weather was ~34°F, calm, and the area was snow covered.
The access road and an area around the wells was plowed. There were several puddles in the plowed area. Conductivity of these puddles was below 100 µS/cm. The snow cover prevented assessment of site stabilization but there was a considerable amount of taller grasses and vegetation visible above the snow. There was 1 properly tagged Marcellus well staged for production. There was a total of 3 well cellars onsite and filled with water; no bubbling was observed. There was 1 GPU, 1 sand separator, and 2 produced water tanks onsite and in secondary containment. There was some water in the produced water tanks containment that was frozen. According to Department records the ESCGP for this site expired on 10/7/15. It is recommended that once site stabilization has been achieved and any erosional issues resolved an NOT be submitted in the spring or summer. No violations noted at the time of inspection. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1929677 | 600042 | 10/18/2010 | 2010-10-18 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | |
1929677 | 600043 | 10/18/2010 | 2010-10-18 | 401 CSL - Discharge of pollultional material to waters of Commonwealth. | Environmental Health & Safety |
For data sources see[8]