If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-113-20305 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.545897,"lon":-76.694553,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Sullivan | |
Municipality: Elkland Township | |
Operator Name: CHIEF OIL & GAS LLC | |
Well Pad ID: 151576 | |
Farm/Lease Name: KUZIAK UNIT B 3H | |
License Status: | |
Spud Date: 2014-10-17 | |
Permit Date: 2014-08-21 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.545897 | |
Longitude: -76.694553 |
Date | Event |
---|---|
2014-08-21 | New Permit Application |
2014-10-17 | Performed Spud Operation |
2015-04-07 | Drilling Completion |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2016-12-27 | 2017-01-02 | 7,054 | 8,890,510 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Methanol | 67-56-1 | 45 | 0.01061 | 9157 | |||
Propargyl alcohol | 107-19-7 | 10 | 0.00002000 | 21 | ||||
Ethylene glycol | 107-21-1 | 30 | 0.0016 | 1385 | ||||
Ethoxylated alcohol | 68551-12-2 | 30 | 0.00007000 | 63 | ||||
Methanol | 67-56-1 | 60 | 0.00015 | 125 | ||||
Quaternary ammonium compound | 68424-85-1 | 10 | 0.00236 | 2035 | ||||
Water | 7732-18-5 | 40 | 0.00943 | 8139 | ||||
Water | 7732-18-5 | 40 | 0.00214 | 1846 | ||||
Acetophenone, thiourea, formaldehyde polymer | 68527-49-1 | 30 | 0.00007000 | 63 | ||||
Acrylamide sodium acrylate copolymer | 25085-02-3 | 30 | 0.02073 | 17895 | ||||
Water | 7732-18-5 | 85 | 0.12246 | 105718 | ||||
Ethanol, 2,2',2-nitrilotris-, 1,1',1-tris(dihydrogen phosphate), sodium salt |
68171-29-9 | 30 | 0.0016 | 1385 | ||||
Fatty acid, tall-oil | 61790-12-3 | 30 | 0.00007000 | 63 | ||||
Hydrochloric acid | 7647-01-0 | 15 | 0.02161 | 18656 | ||||
Crystallilne silica | 14808-60-7 | 100 | 13.8148 | 11,925,800.0 | ||||
Water | 7732-18-5 | 100 | 85.9429 | 74,191,300.0 | ||||
Hydrotreated light petroleum distillate | 64742-47-8 | 30 | 0.02073 | 17895 | ||||
Glutaraldehyde | 111-30-8 | 5 | 0.00118 | 1017 | ||||
Carbonic acid, calcium salt | 471-34-1 | 30 | 0.02073 | 17895 | ||||
Alpha olefins (petroleum), (C11-12) | 64743-02-8 | 5 | 0.00001000 | 10 | ||||
Sand | Haliburton | Propant | Listed Below | |||||
Water | Chief Oil & Gas | Carrier/Base Fluid | Listed Below | |||||
FR-76 | Haliburton | Friction Reducer | Listed Below | |||||
HAI-OS | Haliburton | Acid Inhibitor | Listed Below | |||||
Bioc11219A | Nalco Champion | Biocide | Listed Below | |||||
Hydrochloric Acid (15%) | Haliburton | Acidizing | Listed Below | |||||
EC - 6486A | Nalco Champion | Scale Inhibitor | Listed Below |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2014 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | CHIEF OIL & GAS LLC | 2,008,106.08 | 294 | 0.00 | 0 | 0.00 | 0 |
2018 | CHIEF OIL & GAS LLC | 487,699.06 | 354 | 0.00 | 0 | 0.00 | 0 |
2019 | CHIEF OIL & GAS LLC | 234,198.81 | 318 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2014 | CHIEF OIL & GAS LLC | Drill Cuttings | 58.83 Tons | LANDFILL | 100933 |
2014 | CHIEF OIL & GAS LLC | Drilling Fluid Waste | 769.50 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2014 | CHIEF OIL & GAS LLC | Drill Cuttings | 383.03 Tons | LANDFILL | 301358 |
2015 | CHIEF OIL & GAS LLC | Drilling Fluid Waste | 110.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015 | CHIEF OIL & GAS LLC | Drill Cuttings | 701.31 Tons | LANDFILL | 301358 |
2015 | CHIEF OIL & GAS LLC | Drilling Fluid Waste | 760.76 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2017 | CHIEF OIL & GAS LLC | Produced Fluid | 14,590.48 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2017 | CHIEF OIL & GAS LLC | Produced Fluid | 4,132.35 Bbl | REUSE (AT WELL PAD) | |
2017 | CHIEF OIL & GAS LLC | Produced Fluid | 360.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018 | CHIEF OIL & GAS LLC | Produced Fluid | 1,734.74 Bbl | REUSE (AT WELL PAD) | |
2019 | CHIEF OIL & GAS LLC | Produced Fluid | 482.61 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2340527 | Primary Facility | 2015-01-30 | Preoperation Inspection | No Violations Noted | Arrived on 1/30/15 @14:35, cold, windy, intermittent snow, pad snow-covered. There were 5 cellars in a linear array on the location (photos 3 & 4). Wells may have been tagged, but tags were obscured by snow (photo 1). The wells were not drilled to TD at the time of my inspection. Two vent lines were plumbed into the annuli on each well: (photos 1 &2): |
2359811 | Primary Facility | 2015-04-06 | Drilling/Alteration | No Violations Noted | Arrived @ 13:00, weather sunny, v warm. Haliburton cement trucks were on site at the time of my inspection, having finished the 3H well production casing cement job earlier in the morning. TD for the well was 14,719’. Orion 15 preparing to move to State Game Lands 12 A. Met with company men Bill Delecambre and Denny Lambert. Cement job started @7:20, delayed because getting production casing in place took longer than anticipated. The drilling plan called for a bend in the lateral to get around the Kuziak B 1H and the casing got temporarily stuck. Left location at 13:50. |
2363203 | Primary Facility | 2015-04-13 | Routine/Complete Inspection | No Violations Noted | Arrived @ 12:40. Orion 15 rig left last week. Could not access well heads as pad was still being cleaned. Met Chief representative Aaron Stredny, mentioned clean up issues on the Kuziak pad. Stredny agreed to investigate. Left @13:00. |
2363205 | Primary Facility | 2015-04-13 | Routine/Complete Inspection | No Violations Noted | Arrived @ 12:40. Orion 15 rig left last week. Could not access well heads as pad was still being cleaned. Met Chief representative Aaron Stredny, mentioned clean up issues on the Kuziak pad. Stredny agreed to investigate. Left @13:00. |
2377825 | Primary Facility | 2015-06-09 | Routine/Complete Inspection | No Violations Noted | Arrived on site at 12:30 and Departed at 12:50. Weather conditions were intermittent showers and ~70°F. No Chief representatives were present during the inspection. |
2483290 | Primary Facility | 2016-05-11 | Routine/Complete Inspection | No Violations Noted | Routine inspection to assess overall site conditions. No Chief representatives were present during the inspection.
Overall vegetative cover was >70%; no evidence of accelerated erosion or sedimentation was observed. Conductance was not screened as there were no puddles on the pad surface. A request for a 2-year extension of time for site restoration was received by the Department on 04/07/2016 and is not yet approved. No violations were cited during this inspection. |
2498127 | Primary Facility | 2016-06-30 | Routine/Complete Inspection | No Violations Noted | Arrived @ 10:10. Weather: sunny, warm. No company representatives were present during the inspection. There were 5 wells on the site. There was no GPU or produced water tanks. There were two annular vent pipes for each well. These were open and venting to three 500-gallon polytanks.
Kuziak B 3H, shared a polytank with the 4H well. Cellar full of cloudy fluid. 13-3/8” x 9-5/8”: 0% methane 9-5/8” x 5-1/2”: 0% methane. Left location @ 11:10. |
2509984 | Primary Facility | 2016-08-04 | Follow-up Inspection | No Violations Noted | Arrived @ 10:10. Weather: sunny, warm. No company representatives were present during the inspection. There were 5 wells on the site. There were no GPUs or produced water tanks on site. There were two annular vent pipes for each well. This follow-up inspection was prompted by an Inactive Well Status application for Kuziak Unit B 3H. Previously on 6/30/16, combustible gas was detected on the Kuziak Unit B 5H and 6H wells at the 13-3/8” x 9-5/8” annulus. Typically, the 1” , 13-3/8” x 9-5/8” annular vent T’s into the 2” 13-3/8” x 9-5/8” annular vent, allowing for cross-contamination. To eliminate that possibility in this follow-up inspection, the annuli were open and isolated from each other prior to my arrival on site. Monitoring was conducted with Altair 5X gas meter (calibrated: 7/26/16).
Kuziak B 3H:.13-3/8” x 9-5/8”: 0% /volume combustible gas 9-5/8” x 5-1/2”: 0%/volume combustible gas Left location @ 10:20. |
2516492 | Primary Facility | 2016-08-31 | Follow-up Inspection | No Violations Noted | Arrived @ 13:00. Weather: sunny, warm. Met with Jon Hafer and Peg Farrell (Chief). The purpose of this inspection was to evaluate flow on the Kuziak B 6H and 4H wells and begin PBTs, as a follow-up to previous Inactive Well Status Application inspections for top-hole only wells on this location: Kuziak Unit B 2H, 4H, 5H and 6H wells.
The Kuziak Unit B 3H is TD’ed. Kuziak B 6H: 9-5/8” casing flow: 6180 ft3/day, (differential pressure reading across a 3/8” orifice plate restriction). Kuziak B 4H: 9-5/8” casing flow: 5.28 ft3/day. Jon Hafer set up pressure transducers for the PBT testing and shut-in the annuli. At approximately 14:32 bubbles began to appear in the cellar of the Kuziak B 6H. We agreed to meet back at the site at 09:00 the following day and vac out the cellar to determine the source of the bubbling. Left location @ 14:45. |
2516625 | Primary Facility | 2016-09-01 | Follow-up Inspection | No Violations Noted | Arrived @ 13:00. Weather: sunny, warm. Met with Jon Hafer and Peg Farrell (Chief). The purpose of this inspection was to evaluate flow on the Kuziak B 6H and 4H wells and begin PBTs, as a follow-up to previous Inactive Well Status Application inspections for top-hole only wells on this location: Kuziak Unit B 2H, 4H, 5H and 6H wells.
The Kuziak Unit B 3H is TD’ed. Kuziak B 6H: 9-5/8” casing flow: 6180 ft3/day, (differential pressure reading across a 3/8” orifice plate restriction). Kuziak B 4H: 9-5/8” casing flow: 5.28 ft3/day. Jon Hafer set up pressure transducers for the PBT testing and shut-in the annuli. At approximately 14:32 bubbles began to appear in the cellar of the Kuziak B 6H. We agreed to meet back at the site at 09:00 the following day and vac out the cellar to determine the source of the bubbling. Left location @ 14:45 |
2531981 | Primary Facility | 2016-10-07 | Follow-up Inspection | No Violations Noted | Arrived 11:20 Weather: sunny. Met with company man Floyd Roberts and environmental compliance specialist Jon Hafer (Chief). Workover rig and drilling mud management equipment onsite. To prepare the topholed Kuziak B 2H, 4H, 5H, and 6H wells for Inactive Status, the plan was to remove SOBM, clean and repurpose the mud when possible, and then set balanced cement plugs in the topholed well. During discussions on the pad it emerged that 1ppg brine was being used in between the cement plugs. At the time of my inspection operations were completed on the 2H, 4H, and 5H, and starting on the 6H. Mud in the 5H and 6H mud had separated out to base oil and weighting agent. Fluid level was also down on the 6H. Plan to conduct a follow-up inspection to determine whether the vertical flow of gas has been stopped. No violations were noted during my inspection. Left location @ 12:40. |
2531999 | Primary Facility | 2016-10-24 | Follow-up Inspection | No Violations Noted | Arrived 12:00 Weather: cold, cloudy, windy. Met with environmental compliance specialist Jon Hafer (Chief) for this follow-up inspection at the completion of a 72-hour PBT for the 4H, 5H, and 6H wells. The PBT for the 2H was completed on 10/10/16. There was a frac head on the 3H which had been toe prepped. A DFIT test was underway. For each well, there was no pressure build on the 9-5/8” casing and on the 13-3/8” x 9-5/8” annulus. No violations were noted at the time of this inspection. Left location @ 13:17. |
2553032 | Primary Facility | 2017-01-11 | Routine/Complete Inspection | No Violations Noted | Routine inspection to assess site conditions after fracing operations. No Chief representatives were present during the inspection.
Containment was still in place over a large area of the site. Approximately 1/2" of fresh snow cover was present. No evidence of any spills or relases, such as staining, sheens, or odors, was observed both on and off containment. Puddles that were present on the site were frozen, and thus not screened for electrical conductivity. A request for a 2-year extension of time for site restoration was received by the Department of Environmental Protection on April 07, 2016. To date, that extension request has not been processed. No violations were cited during this inspection. |
2576393 | Primary Facility | 2017-03-28 | Routine/Complete Inspection | No Violations Noted | One well in production phase. Four Wells in regulatory inactive status. One separator within containment. No leaks from production equipment. |
2628069 | Primary Facility | 2017-08-16 | Routine/Complete Inspection | No Violations Noted | Arrived @ 10:30. Weather: hot. There were no personnel onsite at the time of my inspection. 5 wells on site. The Kuziak B 3H was in production. Kuziak B 2H, 4H, 5H, and 6H had Regulatory Inactive Status and were top-holed, and temporarily plugged.
Kuziak B 2H: night cap, annuli plumbed to 500 gallon polytank, no methane detected, very little fluid in tank. Cellar full, no bubbles. Kuziak B 3H: in production, cellar water-filled, no bubbles. Top gauge : 1000 psi (0-5000 psi, analog), 5-1/2” 1100 (0-5000 psi analog). Annuli plumbed to same polytank as Kuziak B4H – no methane detected. Cellar very full, no bubbles, Kuziak B 4H: night cap, annuli plumbed to same polytank as Kuziak B 3H. Cellar very full no bubbles. Kuziak B 5H: night cap, annuli plumbed to same polytank as Kuziak B 6H, no methane detected at polytank. Cellar approx.. ½ full of water, no bubbles. Kuziak B 6H: night cap, annuli plumbed to same polytank as Kuziak B 5H, no methane detected at tank. Cellar full, no bubbles. Previously, prior to th |
2740988 | Primary Facility | 2018-06-13 | Routine/Complete Inspection | No Violations Noted | One well in active status with four wells in regulatory inactive status. No leaks from production equipment. |
For data sources see[8]