{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.832687,"lon":-75.781529,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: New Milford Township | |
Operator Name: SWN PROD CO LLC | |
Well Pad ID: 148273 | |
Farm/Lease Name: ED RANGE REV TRUST 1 | |
License Status: | |
Spud Date: | |
Permit Date: 2008-03-12 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Vertical Well | |
Conservation: Yes | |
Latitude: 41.832687 | |
Longitude: -75.781529 |
Date | Event |
---|---|
2008-03-12 | New Permit Application |
2008-07-16 | Performed Spud Operation |
2008-09-11 | Drilling Completion |
2008-11-12 | NEWLY DRILLED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2008 | SOUTHWESTERN ENERGY PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2009 | SOUTHWESTERN ENERGY PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2010 | SOUTHWESTERN ENERGY PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | SOUTHWESTERN ENERGY PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | SOUTHWESTERN ENERGY PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | SOUTHWESTERN ENERGY PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2008 | SOUTHWESTERN ENERGY PROD CO | Fracking Fluid | 579.00 Bbl | Brine or Industrial Waste Treatment Plt | PA0101508 |
2012 | SOUTHWESTERN ENERGY PROD CO | Drill Cuttings | 2,598.98 Tons | LANDFILL | 101247 |
2013 | SOUTHWESTERN ENERGY PROD CO | Fracing Fluid Waste | 482.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | SOUTHWESTERN ENERGY PROD CO | Drilling Fluid Waste | 194.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | SOUTHWESTERN ENERGY PROD CO | Drill Cuttings | 50.28 Tons | LANDFILL | 101247 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1722963 | Primary Facility | 2008-07-17 | Drilling/Alteration | No Violations Noted | |
1722998 | Primary Facility | 2008-07-16 | Routine/Complete Inspection | No Violations Noted | |
1723104 | Primary Facility | 2008-07-16 | Routine/Complete Inspection | Violation(s) Noted | |
1723140 | Primary Facility | 2008-07-24 | Routine/Complete Inspection | Outstanding Violations - No Viols Req'd | |
1734909 | Primary Facility | 2008-09-04 | Drilling/Alteration | No Violations Noted | |
1741056 | Primary Facility | 2008-09-16 | Drilling/Alteration | No Violations Noted | |
2093107 | Primary Facility | 2012-08-14 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | CC Forbes rig on site. Plugs have been set. Pulling rig off location. Walked site - on far corner observed sheen on water - collecting on containment. Crews immediately put down absorbent pads. Likely from power washing rig -residual oil and grease. All fluid on containment. Notified Company Man of issue. he said he would have vac truck sent to site to suck up fluid from containment. See plugging schematic in file. operator will cut and weld cap with permit # on top of well tomorrow. Well is cut off below plow depth. |
2106874 | Primary Facility | 2012-09-26 | Follow-up Inspection | No Violations Noted | Operator called to report bubbling observed around well head. WEll had been been recently plugged in August of this year. Crews on site in process of reclaiming site and noticed bubbling. At time of arrival excavator on site loading surface stone from pad into dumptrucks. Well surounded by construction fence. Water around base of well due to rain. WEll cut off below grade and has welded cap. Bubbling was confirmed between 9 5/8" and 13 3/8" casing strings. Bubbling is steady. I met with construction supervisor and informed him I would be contacting Rich Gulyas of SWN to set up meeting to disuss well. I took pictures of well. 16:00 I spoke with Mr. Gulyas and will be setting up meeting to discuss plan going forward to address bubbling. |
2110262 | Primary Facility | 2012-10-16 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Well has been plugged. Upon completion of plugging - observed bubbling around well head. Have met with SWN on 10/1/12. to discuss plans to remediate. At time of inspection, area around well head is full of water, and bubbling present. Crew on site with excavator removing reserve pit. SWN in process of installing gauge on well to monitor pressure. |
2110270 | Primary Facility | 2012-10-17 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | |
2139958 | Primary Facility | 2013-02-05 | Plugging(Includes Plugged/Mined Through) | Violation(s) Noted | NOV written for failure to properly plug and abandon well. See Insp ID 2219034, well plugged. |
2175463 | Primary Facility | 2013-06-05 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | See Insp ID 2219034, well plugged. |
2179914 | Primary Facility | 2013-05-29 | Drilling/Alteration | No Violations Noted | CC Forbes 77 on location. Currently fishing. See Insp ID 2219034, well plugged. |
2217505 | Primary Facility | 2013-09-19 | Plugging(Includes Plugged/Mined Through) | Outstanding Violations - No Viols Req'd | foolowup on well plugging. Checked various annuli (off risers). Unable to differentiate annuli. 0% off two annuli. 90% spike LEL off another. (80% continuous). SWN to provide diagram of wellhead to determine which annuli methane detected. See Insp ID 2219034, well plugged. |
2219034 | Primary Facility | 2013-10-08 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Set balamced plug from 449-349'. 43 sacks, 15.6 ppg, 1.4 bbls displaced. 0% LEL off 9 X 5 and 13 X 9. REsidual gas off of 13 X 20 - .03%. Well plugged, allowed company to begin restoring site. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1723104 | 543977 | 07/16/2008 | 2008-07-16 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | |
1723104 | 543978 | 07/16/2008 | 2008-07-16 | 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used | Administrative | 102.22 |
2139958 | 660888 | 02/05/2013 | 2013-02-05 | 210UNPLUG - Failure to plug a well upon abandonment | Administrative | See Insp ID 2219034, well plugged. |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
543977 | 236811 | NOV - Notice of Violation | Comply/Closed | 2008-09-16 | |||
543978 | 236811 | NOV - Notice of Violation | Comply/Closed | 2008-09-16 |
For data sources see[7]