If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-20169 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.861885,"lon":-76.018836,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Forest Lake Township | |
Operator Name: SWN PROD CO LLC | |
Well Pad ID: 150596 | |
Farm/Lease Name: POWERS 1H | |
License Status: | |
Spud Date: | |
Permit Date: 2009-05-18 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.861885 | |
Longitude: -76.018836 |
Date | Event |
---|---|
2009-05-18 | New Permit Application |
2009-09-17 | Performed Spud Operation |
2009-09-22 | Drilling Completion |
2009-10-10 | Perforation |
2009-10-10 | Performed Stimulation |
2009-11-23 | DEVIATED |
For data sources see[4]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2009-10-10 | 0 | 0 | 0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2009 | ALTA OPR CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2010 | XPR RESOURCES LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | XPR RESOURCES LLC | 165,742.00 | 39 | 0.00 | 0 | 0.00 | 0 |
2012 | XPR RESOURCES LLC | 747,043.14 | 355 | 0.00 | 0 | 0.00 | 0 |
2013 | XPR RESOURCES LLC | 588,147.13 | 362 | 0.00 | 0 | 0.00 | 0 |
2014 | XPR RESOURCES LLC | 504,536.08 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | SWN PROD CO LLC | 427,542.64 | 363 | 0.00 | 0 | 0.00 | 0 |
2016 | SWN PROD CO LLC | 343,695.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | SWN PROD CO LLC | 299,357.00 | 364 | 0.00 | 0 | 0.00 | 0 |
2018 | SWN PROD CO LLC | 249,433.00 | 361 | 0.00 | 0 | 0.00 | 0 |
2019 | SWN PROD CO LLC | 216,567.00 | 335 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2013 | XPR RESOURCES LLC | Produced Fluid | 107.29 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2013 | XPR RESOURCES LLC | Produced Fluid | 209.43 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2013 | XPR RESOURCES LLC | Produced Fluid | 102.38 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
2013 | XPR RESOURCES LLC | Produced Fluid | 109.24 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NC010 |
2014 | XPR RESOURCES LLC | Produced Fluid | 50.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2014 | XPR RESOURCES LLC | Produced Fluid | 577.88 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2014 | XPR RESOURCES LLC | Produced Fluid | 191.91 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2014 | XPR RESOURCES LLC | Produced Fluid | 210.24 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015 | SOUTHWESTERN ENERGY PROD CO | Produced Fluid | 433.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SWN PROD CO LLC | Produced Fluid | 440.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | SWN PROD CO LLC | Produced Fluid | 826.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017 | SWN PROD CO LLC | Other Oil & Gas Wastes | 304.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 177.44 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018 | SWN PROD CO LLC | Produced Fluid | 110.00 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 160.00 Bbl | REUSE (AT WELL PAD) | |
2019 | SWN PROD CO LLC | Other Oil & Gas Wastes | 21.74 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019 | SWN PROD CO LLC | Produced Fluid | 93.77 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2019 | SWN PROD CO LLC | Produced Fluid | 125.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019 | SWN PROD CO LLC | Spent Lubricant Waste | 110.00 Bbl | RESIDUAL WASTE TRANSFER FACILITY | 101532 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1817540 | Primary Facility | 2009-07-31 | Routine/Complete Inspection | No Violations Noted | An existing road was used to access the well site. The road and drill pad are stoned with limestone. The Site ID sign and E/S Plan were present at the entrance of the access road. At the time of inspection, there was no drill rig on site. The contractor (Barber and Deline) were on site loading materials to be moved off location. Barber and Deline were contracted to set the conductor and mouse hole, which were observed on location. Metal caps were welded on each. |
1825891 | Primary Facility | 2009-08-27 | Drilling/Alteration | No Violations Noted | An existing road was used to access the well site. The road and drill pad are stoned with limestone. The Site ID sign and E/S Plan were present at the entrance of the access road. At the time of inspection, drill rig Pioneer #60 was on site. I met with Company Man John Mode who informed me that the current depth of drilling was 1226'. Mr Mode indicated that they were currently drilling down to a projected depth of 1445' at which point they will be setting 9-5/8" surface casing. Cementing of the surface casing would likely occur sometime this evening according to Mr. Mode. |
1833755 | Primary Facility | 2009-07-21 | Routine/Complete Inspection | No Violations Noted | |
1846056 | Primary Facility | 2009-11-24 | Routine/Complete Inspection | Violation(s) Noted | |
1895762 | Primary Facility | 2010-06-29 | Follow-up Inspection | No Violations Noted | |
1941208 | Primary Facility | 2011-01-05 | Routine/Complete Inspection | No Violations Noted | |
1965928 | Primary Facility | 2011-04-15 | Routine/Complete Inspection | No Violations Noted | Inspected well head. Appears to be small leak on 2 vent line. Could not determine what 2" vent line is connected to due to cellar being filled in with gravel. There is also a 2500lb gauge on top of the well head which is connectedto teh production strin. Threre is a crew on site spreading hay on rear fill slope of the well pad and also installing super silt fence. |
1968301 | Primary Facility | 2011-04-13 | Routine/Complete Inspection | Violation(s) Noted | |
1968796 | Primary Facility | 2011-04-27 | Follow-up Inspection | No Violations Noted | |
2314892 | Primary Facility | 2014-10-22 | Site Restoration | No Violations Noted | |
2404503 | Primary Facility | 2015-09-03 | Routine/Complete Inspection | No Violations Noted | |
2448286 | Primary Facility | 2016-01-21 | Routine/Complete Inspection | No Violations Noted | The Department was on site to conduct a routine complete inspection of the Powers 1H well site (WR-65 Pad)(ESX11-115-0008). The well associated with this site is the 115-20169.
The site was in good shape, and had no issues of any consequence. The site work followed the plans. There were no erosional issues with the site, all slopes were stable and there were no failures of BMPs to note. There were no violations. If there are any questions please feel free to call me at (570) 346-5539. |
2505614 | Primary Facility | 2016-07-26 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 10:25a.m., the cellar was full of gravel and no gas was detected. The vent pipe was open and set up with a Taylor plug; there was 199psi on the production casing and 112psi on the production line. I took a walk around the location and everything looked OK.
I left the site at 10:50a.m. |
2599629 | Primary Facility | 2017-05-31 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 8:30a.m.
The cellar was full of gravel with water setting on top with bubbling noticed. I detected gas at 100% LEL and peaked at 26% methane. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure with a Crystal pressure gauge. There was 395psi on the production casing and 109psi on the production line. I took a walk around the location and there were no other obvious concerns noticed. I left the site at 9:00a.m. I contacted Steve Moyer of SWN to set up a follow up inspection to determine where the bubbling is coming from. |
2602042 | Primary Facility | 2017-06-06 | Follow-up Inspection | No Violations Noted | At time of inspection, arrived on site at 8:50a.m. for a follow up inspection.
During a routine inspection conducted on 5/31/17, bubbling was noticed in the cellar and gas was detected. I met with Cody Stanton (production foreman for SWN). The cellar was full of water and a water truck was on site to vac the water level down so the source of the bubbling could be determined. The bubbling was coming from the treads of a bull plug that was screwed into the production head across from the (9x5) annulus vent pipe. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure with a Crystal pressure gauge, Cody check the pressure at 117psi. I left the site at 9:20a.m. |
2704687 | Primary Facility | 2018-03-13 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The cellar was set up with a corrugated pipe around the well for inspection access with water 1' below grade. The (20x13) and (13x9) annuli were below the water level and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2804352 | Primary Facility | 2018-11-16 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. The cellar was set up with a plastic corrugated pipe around the well for inspection access. There was water 1' below grade in the cellar and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1846056 | 576548 | 11/24/2009 | 2009-11-24 | 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used | Administrative | See Insp ID 1895762 done 6/29/10, past viols closed. Failure to contain pollutional substances in a lined pit or tank 25 PA Code 78.56(a) |
1846056 | 576549 | 11/24/2009 | 2009-11-24 | 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used | Administrative | See Insp ID 1895762 done 6/29/10, past viols closed. Failure to manage residual waste. 35 PA 6018.301 |
1846056 | 576550 | 11/24/2009 | 2009-11-24 | 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used | Administrative | See Insp ID 1895762 done 6/29/10, past viols closed. Potential pollution 35 PS 691.402 |
1846056 | 576551 | 11/24/2009 | 2009-11-24 | 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used | Administrative | See Insp ID 1895762 done 6/29/10, past viols closed. Failure to report an incident. 25 PA Code 91.33(a) |
1968301 | 609527 | 04/13/2011 | 2011-04-13 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
576548 | 252969 | NOV - Notice of Violation | Comply/Closed | 2010-06-29 | |||
576549 | 252969 | NOV - Notice of Violation | Comply/Closed | 2010-06-29 | |||
576550 | 252969 | NOV - Notice of Violation | Comply/Closed | 2010-06-29 | |||
576551 | 252969 | NOV - Notice of Violation | Comply/Closed | 2010-06-29 |
For data sources see[8]