37-115-20169

Well Details

Well ID: 37-115-20169
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Forest Lake Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 150596
Farm/Lease Name: POWERS 1H
License Status:
Spud Date:
Permit Date: 2009-05-18
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.861885
Longitude: -76.018836

For data sources see[1][2][3]

Well History

Date Event
2009-05-18 New Permit Application
2009-09-17 Performed Spud Operation
2009-09-22 Drilling Completion
2009-10-10 Perforation
2009-10-10 Performed Stimulation
2009-11-23 DEVIATED

For data sources see[4]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2009-10-10 0 0 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 ALTA OPR CO LLC 0.00 0 0.00 0 0.00 0
2010 XPR RESOURCES LLC 0.00 0 0.00 0 0.00 0
2011 XPR RESOURCES LLC 165,742.00 39 0.00 0 0.00 0
2012 XPR RESOURCES LLC 747,043.14 355 0.00 0 0.00 0
2013 XPR RESOURCES LLC 588,147.13 362 0.00 0 0.00 0
2014 XPR RESOURCES LLC 504,536.08 365 0.00 0 0.00 0
2015 SWN PROD CO LLC 427,542.64 363 0.00 0 0.00 0
2016 SWN PROD CO LLC 343,695.00 366 0.00 0 0.00 0
2017 SWN PROD CO LLC 299,357.00 364 0.00 0 0.00 0
2018 SWN PROD CO LLC 249,433.00 361 0.00 0 0.00 0
2019 SWN PROD CO LLC 216,567.00 335 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 XPR RESOURCES LLC Produced Fluid 107.29 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013 XPR RESOURCES LLC Produced Fluid 209.43 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2013 XPR RESOURCES LLC Produced Fluid 102.38 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2013 XPR RESOURCES LLC Produced Fluid 109.24 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC010
2014 XPR RESOURCES LLC Produced Fluid 50.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2014 XPR RESOURCES LLC Produced Fluid 577.88 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014 XPR RESOURCES LLC Produced Fluid 191.91 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014 XPR RESOURCES LLC Produced Fluid 210.24 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2015 SOUTHWESTERN ENERGY PROD CO Produced Fluid 433.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Produced Fluid 440.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWN PROD CO LLC Produced Fluid 826.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Other Oil & Gas Wastes 304.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Other Oil & Gas Wastes 177.44 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Produced Fluid 110.00 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Other Oil & Gas Wastes 160.00 Bbl REUSE (AT WELL PAD)
2019 SWN PROD CO LLC Other Oil & Gas Wastes 21.74 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 93.77 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 SWN PROD CO LLC Produced Fluid 125.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Spent Lubricant Waste 110.00 Bbl RESIDUAL WASTE TRANSFER FACILITY 101532

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1817540 Primary Facility 2009-07-31 Routine/Complete Inspection No Violations Noted An existing road was used to access the well site. The road and drill pad are stoned with limestone. The Site ID sign and E/S Plan were present at the entrance of the access road. At the time of inspection, there was no drill rig on site. The contractor (Barber and Deline) were on site loading materials to be moved off location. Barber and Deline were contracted to set the conductor and mouse hole, which were observed on location. Metal caps were welded on each.
1825891 Primary Facility 2009-08-27 Drilling/Alteration No Violations Noted An existing road was used to access the well site. The road and drill pad are stoned with limestone. The Site ID sign and E/S Plan were present at the entrance of the access road. At the time of inspection, drill rig Pioneer #60 was on site. I met with Company Man John Mode who informed me that the current depth of drilling was 1226'. Mr Mode indicated that they were currently drilling down to a projected depth of 1445' at which point they will be setting 9-5/8" surface casing. Cementing of the surface casing would likely occur sometime this evening according to Mr. Mode.
1833755 Primary Facility 2009-07-21 Routine/Complete Inspection No Violations Noted
1846056 Primary Facility 2009-11-24 Routine/Complete Inspection Violation(s) Noted
1895762 Primary Facility 2010-06-29 Follow-up Inspection No Violations Noted
1941208 Primary Facility 2011-01-05 Routine/Complete Inspection No Violations Noted
1965928 Primary Facility 2011-04-15 Routine/Complete Inspection No Violations Noted Inspected well head. Appears to be small leak on 2 vent line. Could not determine what 2" vent line is connected to due to cellar being filled in with gravel. There is also a 2500lb gauge on top of the well head which is connectedto teh production strin. Threre is a crew on site spreading hay on rear fill slope of the well pad and also installing super silt fence.
1968301 Primary Facility 2011-04-13 Routine/Complete Inspection Violation(s) Noted
1968796 Primary Facility 2011-04-27 Follow-up Inspection No Violations Noted
2314892 Primary Facility 2014-10-22 Site Restoration No Violations Noted
2404503 Primary Facility 2015-09-03 Routine/Complete Inspection No Violations Noted
2448286 Primary Facility 2016-01-21 Routine/Complete Inspection No Violations Noted The Department was on site to conduct a routine complete inspection of the Powers 1H well site (WR-65 Pad)(ESX11-115-0008). The well associated with this site is the 115-20169.

The site was in good shape, and had no issues of any consequence. The site work followed the plans.

There were no erosional issues with the site, all slopes were stable and there were no failures of BMPs to note.

There were no violations.

If there are any questions please feel free to call me at (570) 346-5539.

2505614 Primary Facility 2016-07-26 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 10:25a.m., the cellar was full of gravel and no gas was detected. The vent pipe was open and set up with a Taylor plug; there was 199psi on the production casing and 112psi on the production line. I took a walk around the location and everything looked OK.

I left the site at 10:50a.m.

2599629 Primary Facility 2017-05-31 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 8:30a.m.

The cellar was full of gravel with water setting on top with bubbling noticed. I detected gas at 100% LEL and peaked at 26% methane. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure with a Crystal pressure gauge. There was 395psi on the production casing and 109psi on the production line. I took a walk around the location and there were no other obvious concerns noticed. I left the site at 9:00a.m. I contacted Steve Moyer of SWN to set up a follow up inspection to determine where the bubbling is coming from.

2602042 Primary Facility 2017-06-06 Follow-up Inspection No Violations Noted At time of inspection, arrived on site at 8:50a.m. for a follow up inspection.

During a routine inspection conducted on 5/31/17, bubbling was noticed in the cellar and gas was detected. I met with Cody Stanton (production foreman for SWN). The cellar was full of water and a water truck was on site to vac the water level down so the source of the bubbling could be determined. The bubbling was coming from the treads of a bull plug that was screwed into the production head across from the (9x5) annulus vent pipe. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure with a Crystal pressure gauge, Cody check the pressure at 117psi. I left the site at 9:20a.m.

2704687 Primary Facility 2018-03-13 Routine/Complete Inspection No Violations Noted At time of inspection.

The cellar was set up with a corrugated pipe around the well for inspection access with water 1' below grade. The (20x13) and (13x9) annuli were below the water level and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2804352 Primary Facility 2018-11-16 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was set up with a plastic corrugated pipe around the well for inspection access. There was water 1' below grade in the cellar and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1846056 576548 11/24/2009 2009-11-24 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used Administrative See Insp ID 1895762 done 6/29/10, past viols closed. Failure to contain pollutional substances in a lined pit or tank 25 PA Code 78.56(a)
1846056 576549 11/24/2009 2009-11-24 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used Administrative See Insp ID 1895762 done 6/29/10, past viols closed. Failure to manage residual waste. 35 PA 6018.301
1846056 576550 11/24/2009 2009-11-24 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used Administrative See Insp ID 1895762 done 6/29/10, past viols closed. Potential pollution 35 PS 691.402
1846056 576551 11/24/2009 2009-11-24 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used Administrative See Insp ID 1895762 done 6/29/10, past viols closed. Failure to report an incident. 25 PA Code 91.33(a)
1968301 609527 04/13/2011 2011-04-13 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
576548 252969 NOV - Notice of Violation Comply/Closed 2010-06-29
576549 252969 NOV - Notice of Violation Comply/Closed 2010-06-29
576550 252969 NOV - Notice of Violation Comply/Closed 2010-06-29
576551 252969 NOV - Notice of Violation Comply/Closed 2010-06-29

For data sources see[8]

References