37-115-20175

Well Details

Well ID: 37-115-20175
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Forest Lake Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 145829
Farm/Lease Name: IVEY 1H
License Status:
Spud Date:
Permit Date: 2009-06-11
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.890005
Longitude: -75.938138

For data sources see[1][2][3]

Well History

Date Event
2009-06-11 New Permit Application
2009-12-09 Performed Spud Operation
2010-02-28 Drilling Completion
2012-02-26 Perforation
2012-02-26 Performed Stimulation
2012-06-22 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-03-03 2012-03-03 6,666 1,961,292

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 SP Breaker Halliburton Energy Services Breaker Sodium persulfate 7775-27-1 100.00 0.00127000
Cla-Web Halliburton Energy Services Clay Control
Proprietary 60.00 0.02
GBW-30 Breaker Halliburton Energy Services Breaker Carbohydrates 95.00 0.00121000
Hemicellulase enzyme 9012-54-8 15.00 0.00019000
Hydrochloric Acid Halliburton Energy Services Acid Hydrochloric acid 7647-01-0 30.00 0.13
WG-36 Gelling Agent Halliburton Energy Services Gel
Guar gum 9000-30-0 100.00 0.00169000
LP-65 Halliburton Energy Services Scale Inhibitor Ammonium chloride 12125-02-9 10.00 0.00388000
BE-9M Halliburton Energy Services Biocide Tri-n-butyl tetradecyl phosphonium chloride 81741-28-8 10.00 0.00095000
Methanol 67-56-1 30.00 0.00285000
Sand- Silica Sand Halliburton Energy Services Proppant Quartz 14808-60-7 100.00 14.88
Water Carrier/Base Fluid Water 100.00 84.92
FR-66 Friction Reducer Halliburton Energy Services Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.01

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2012-02-26 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 XPR RESOURCES LLC 0.00 0 0.00 0 0.00 0
2011 XPR RESOURCES LLC 0.00 0 0.00 0 0.00 0
2012 XPR RESOURCES LLC 218,658.80 75 0.00 0 0.00 0
2013 XPR RESOURCES LLC 577,381.56 364 0.00 0 0.00 0
2014 XPR RESOURCES LLC 390,018.69 325 0.00 0 0.00 0
2015 SWN PROD CO LLC 277,057.16 356 0.00 0 0.00 0
2016 SWN PROD CO LLC 219,181.00 363 0.00 0 0.00 0
2017 SWN PROD CO LLC 135,568.00 261 0.00 0 0.00 0
2018 SWN PROD CO LLC 126,972.00 346 0.00 0 0.00 0
2019 SWN PROD CO LLC 110,936.00 364 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 XPR RESOURCES LLC Drill Cuttings 1,422.72 Tons CENTRALIZED TREATMENT PLANT FOR RECYCLE PAD085690592
2010 XPR RESOURCES LLC Drilling Fluid Waste 1,528.60 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 301353
2012 XPR RESOURCES LLC Produced Fluid 227.12 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2013 XPR RESOURCES LLC Produced Fluid 153.73 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2013 XPR RESOURCES LLC Produced Fluid 646.29 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013 XPR RESOURCES LLC Produced Fluid 383.08 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2013 XPR RESOURCES LLC Produced Fluid 409.90 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2013 XPR RESOURCES LLC Produced Fluid 398.43 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2013 XPR RESOURCES LLC Produced Fluid 417.86 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC010
2013 XPR RESOURCES LLC Produced Fluid 215.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2014 XPR RESOURCES LLC Produced Fluid 232.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2014 XPR RESOURCES LLC Produced Fluid 1,650.60 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2014 XPR RESOURCES LLC Produced Fluid 349.72 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014 XPR RESOURCES LLC Produced Fluid 429.14 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 SWN PROD CO LLC Servicing Fluid 220.00 Bbl RESIDUAL WASTE TRANSFER FACILITY 101532
2015 SOUTHWESTERN ENERGY PROD CO Produced Fluid 874.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Produced Fluid 778.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Produced Fluid 51.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2017 SWN PROD CO LLC Other Oil & Gas Wastes 70.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Produced Fluid 1,197.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Other Oil & Gas Wastes 50.00 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Produced Fluid 330.00 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Produced Fluid 110.00 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Produced Fluid 330.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Other Oil & Gas Wastes 294.15 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 436.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Other Oil & Gas Wastes 21.74 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 104.00 Bbl SURFACE IMPOUNDMENT 826342

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1852637 Primary Facility 2009-11-17 Routine/Complete Inspection No Violations Noted
1852642 Primary Facility 2009-12-03 Routine/Complete Inspection No Violations Noted
1864547 Primary Facility 2010-02-18 Drilling/Alteration No Violations Noted : Rig on site is Pioneer 60. At the time of inspection drilling depth was at TD of 9790'. Operator will be setting 5.5" production casing downhole which will be cemented from KOP to approximately 2500' with 15% excess. 7-7/8" rigid type centralizers will be run in middle of 1st joint, and then floated on every other joint through top of curve. 8-3/4" bow type centralizers will be run every third joint to 2500'.
1884335 Primary Facility 2010-04-20 Routine/Complete Inspection Violation(s) Noted
1884339 Primary Facility 2010-04-22 Follow-up Inspection Violation(s) Noted
1884928 Primary Facility 2010-05-17 Follow-up Inspection Outstanding Violations - No Viols Req'd
1941210 Primary Facility 2011-01-05 Routine/Complete Inspection No Violations Noted
2218443 Primary Facility 2013-10-28 Routine/Partial Inspection No Violations Noted
2355140 Primary Facility 2015-03-26 Routine/Complete Inspection No Violations Noted
2422677 Primary Facility 2015-11-05 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 12:30, the cellar was full of gravel, the vent pipe was open and set up with a Taylor plug, there was no gas detected at the perimeter of the cellar, there was about 245psi on the production casing and 176psi on the production line. I took a walk around the location, everything looked OK.
2484448 Primary Facility 2016-05-03 Routine/Partial Inspection No Violations Noted The Department was on site at the Ivey Well Site to conduct a Routine Partial Inspection. At the time of the inspection, the Department noted that the E&S Inspection Checklist noted that an inspection was conducted on 4/28/16. The Department noticed that there was a redline change on the plan map from 10/18/11 that stated that Carrizo’s access road is in a forested wetland and that they were notified. Also noted on the plan map was that the UNT to Fall Brook was unclassified under Chapter 93. The Department requests that the operator investigate the stream classification of the UNT to Fall Brook. Between the forest and the access drive is an area that appears to have been re-vegetated. Tree tubes and wetland vegetation were noted in the area.

A large mulch pile is situated at the base of the fill slope. There is also an area of the fill slope that has been rock lined. A large rock pile is present in the corner of the well site. The perimeter ditch does not appear to meet temporary stabilization requi

2513782 Primary Facility 2016-08-25 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 13:25p.m., the cellar was full of gravel and no gas was detected. The vent pipe was open and set up with a Taylor plug to check for pressure, there was 257psi on the production casing and 240psi on the production line. I took a walk around the location and everything looked OK.

I left the site at 13:45p.m.

2528853 Primary Facility 2016-09-29 Routine/Complete Inspection No Violations Noted The Department, represented by Frank Hoehle and Jon Sassi were on site to conduct a RTNC inspection of the Ivey GU1H well site. The ESX number for this site is ESX11-115-0019.

The well associated with this site is:

115-20175.

There was a large spoil pile on the North Northwest corner of the pad, and according to Afton Sterling, SWN representative, it was inherited when SWN took control of Alta holdings. The material appears to be rock and there was no sheen or high conductivity in the area. The well has its own compressor station and has a plunger lift installed to help boost production. There is no containment under GPU.

There were no erosional issues with the site, all slopes were stable and there were no failures of BMPs to note.

There were no violations.

If there are any questions please feel free to call me at (570) 346-5539.

2608740 Primary Facility 2017-06-28 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 11:15a.m.

The cellar was full of gravel and there was no gas detected at the perimeter of the cellar. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure with a Crystal pressure gauge. There was 471psi on the production casing and there was no reading on the Schneider digital pressure gauge on the production line. The well was not producing at time of inspection, the valve at the GPU was closed. I took a walk around the location and there were no obvious concerns noticed. I left the site at 11:45a.m.

2714825 Primary Facility 2018-04-05 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was full of gravel and there was no gas detected at the perimeter of the cellar. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2816409 Primary Facility 2018-12-17 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was full of gravel and there was no gas detected at the perimeter of the cellar. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1884335 586997 04/20/2010 2010-04-20 78.56PITCNST - Impoundment not structurally sound, impermeable, 3rd party protected, greater than 20" of seasonal high ground water table Administrative 78.56(a)(4)- Tears in liner
1884335 586998 04/20/2010 2010-04-20 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used Administrative 691.402- black fluid noted on ground around tanks, and leaking from hose
1884335 586999 04/20/2010 2010-04-20 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used Administrative 6018.301- Failure to manage solid waste
1884339 590767 04/22/2010 2010-04-22 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used Administrative 691.402- Tophole cuttings washed down the fill slope and into a small pond
1884339 590768 04/22/2010 2010-04-22 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used Administrative 6018.301- Failure to manage residual waste

For data sources see[9]

References