37-115-20188

Well Details

Well ID: 37-115-20188
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Liberty Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 149477
Farm/Lease Name: TURNER 1H
License Status:
Spud Date:
Permit Date: 2009-07-16
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.969817
Longitude: -75.887829

For data sources see[1][2][3]

Well History

Date Event
2009-07-16 New Permit Application
2009-12-09 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-04-25 2012-04-25 5,802 3,497,613

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1
Cla-Web Halliburton Energy Services Clay Control Proprietary 60.00 0.02
BE-9M Halliburton Energy Services Biocide
Methanol 67-56-1 30.00 0.01
Tri-n-butyl tetradecyl phosphonium chloride 81741-28-8 10.00 0.00478000
FR-66 Friction Reducer Halliburton Energy Services Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.01
GBW-30 Breaker Halliburton Energy Services Breaker Hemicellulase enzyme 9012-54-8 15.00 0.00013000
Carbohydrates 95.00 0.00080000
LP-65 Halliburton Energy Services Scale Inhibitor Ammonium chloride 12125-02-9 10.00 0.00396000
SP Breaker Halliburton Energy Services Breaker Sodium persulfate 7775-27-1 100.00 0.00084000
WG-36 Gelling Agent Halliburton Energy Services Gel Guar gum 9000-30-0 100.00 0.00165000
Water Carrier/Base Fluid Water 100.00 85.76
Hydrochloric Acid Halliburton Energy Services Acid Hydrochloric acid 7647-01-0 30.00 0.12
Sand- Silica Sand Halliburton Energy Services Proppant Quartz 14808-60-7 100.00 14.04

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 XPR RESOURCES LLC 0.00 0 0.00 0 0.00 0
2011 XPR RESOURCES LLC 0.00 0 0.00 0 0.00 0
2012 XPR RESOURCES LLC 0.00 0 0.00 0 0.00 0
2013 XPR RESOURCES LLC 380,962.56 242 0.00 0 0.00 0
2014 XPR RESOURCES LLC 313,321.03 365 0.00 0 0.00 0
2015 SWN PROD CO LLC 276,082.24 364 0.00 0 0.00 0
2016 SWN PROD CO LLC 240,651.00 366 0.00 0 0.00 0
2017 SWN PROD CO LLC 120,747.00 274 0.00 0 0.00 0
2018 SWN PROD CO LLC 105,807.00 285 0.00 0 0.00 0
2019 SWN PROD CO LLC 120,514.00 351 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 XPR RESOURCES LLC Drill Cuttings 525.62 Tons CENTRALIZED TREATMENT PLANT FOR RECYCLE PAD085690592
2010 XPR RESOURCES LLC Drilling Fluid Waste 1,523.80 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 301353
2013 XPR RESOURCES LLC Produced Fluid 510.99 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2013 XPR RESOURCES LLC Fracing Fluid Waste 110.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2013 XPR RESOURCES LLC Produced Fluid 1,963.31 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013 XPR RESOURCES LLC Produced Fluid 1,366.30 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2013 XPR RESOURCES LLC Produced Fluid 2,673.90 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2013 XPR RESOURCES LLC Produced Fluid 903.21 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2013 XPR RESOURCES LLC Produced Fluid 633.38 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC010
2013 XPR RESOURCES LLC Produced Fluid 781.05 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2013 XPR RESOURCES LLC Produced Fluid 314.94 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2014 XPR RESOURCES LLC Produced Fluid 217.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2014 XPR RESOURCES LLC Produced Fluid 2,674.21 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2014 XPR RESOURCES LLC Produced Fluid 419.62 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014 XPR RESOURCES LLC Produced Fluid 608.07 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 SWN PROD CO LLC Fracing Fluid Waste 20.00 Bbl LANDFILL THR029
2015 SOUTHWESTERN ENERGY PROD CO Produced Fluid 3,051.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Produced Fluid 361.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016 SWN PROD CO LLC Produced Fluid 1,870.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWN PROD CO LLC Other Oil & Gas Wastes 278.50 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Produced Fluid 1,886.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Produced Fluid 88.00 Bbl REUSE (AT WELL PAD)
2017 SWN PROD CO LLC Produced Fluid 110.00 Bbl REUSE OTHER THAN ROAD SPREADING
2018 SWN PROD CO LLC Other Oil & Gas Wastes 50.00 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Produced Fluid 664.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Produced Fluid 330.00 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Produced Fluid 440.00 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Other Oil & Gas Wastes 117.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 108.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC035
2019 SWN PROD CO LLC Produced Fluid 830.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Other Oil & Gas Wastes 21.74 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 475.00 Bbl SURFACE IMPOUNDMENT 826342

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1910530 Primary Facility 2010-08-30 Drilling/Alteration No Violations Noted
1916793 Primary Facility 2010-09-29 Drilling/Alteration Violation(s) Noted
1919668 Primary Facility 2010-10-13 Follow-up Inspection Outstanding Violations - No Viols Req'd Well is shut in. No activity on site. Observed constant bubbling around well head in between 9 5/8" and 13 3/8" casing strings. Violation has already been cited for the well conditions. no additional violations were cited during this inspection.
1942726 Primary Facility 2010-12-29 Routine/Complete Inspection No Violations Noted
1944047 Primary Facility 2011-01-19 Routine/Complete Inspection No Violations Noted
2144073 Primary Facility 2013-02-28 Routine/Complete Inspection No Violations Noted At time of inspection there was no activity on site. Access road gated. Only well drilled on pad. Well is shut in. Guage on production string shows 2250 lbs. Well tag in place. Site ID sign in place. Well has been fracced as of 8/04/12. Inspected cellar - cellar is filled in with gravel. No violations observed at time of inspection.
2316091 Primary Facility 2014-09-30 Routine/Partial Inspection No Violations Noted
2364599 Primary Facility 2015-04-27 Routine/Complete Inspection No Violations Noted
2423968 Primary Facility 2015-11-10 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 11:00 a.m., the cellar was full of gravel, there were two vent pipes with no tags venting into the atmosphere, there was no gas detected from either vent pipe, there was gas detected at the perimeter of the cellar at 18% combustible, there was 357psi on the production casing and 267psi on the production line. I met with well tender Tyler Rowe to determine the source of the gas. Tyler dug a hole about one foot deep where gas was detected, I checked for gas at the flange of the well head and there was no gas detected. I noticed a drip from a fitting on the well head, Tyler tightened the fitting and it was determined that it was the source of the reading. I took a walk around the location and everything looked OK.
2508828 Primary Facility 2016-04-20 Routine/Complete Inspection No Violations Noted Inspection of the Turner well pad in conjunction with the Silver Lake Gathering System South - Line 419 pipeline notice of termination inspection. There were no issues observed on the well pad at the time of the inspection.
2508855 Primary Facility 2016-05-10 Routine/Complete Inspection No Violations Noted Inspection of the Turner well pad in conjunction with the Northeast Gathering Phase 3 Gathering System - Line 418 pipeline notice of termination inspection. There were no issues observed on the well pad at the time of the inspection.
2519025 Primary Facility 2016-09-13 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 12:45p.m., the cellar was full of gravel and no gas was detected. The vent pipe was open and set up with a Taylor plug to check for pressure, there was 217psi on the production casing and 111psi on the production line. I took a walk around the location and everything looked OK.

I left the site at 13:10p.m.

2538282 Primary Facility 2016-11-21 Site Restoration No Violations Noted The Department (Steve Brokenshire and I) was on site to conduct a Restoration Inspection in response to the submittal of a Notice of Termination (NOT).

The E&S Inspection Checklist indicated that on 11/14/2016, S. Maya performed a weekly inspection and noted that no attention was needed.

There appears to be landowner disturbance on the NW side of the well site. Palletized stone and 5 gallon buckets are situated in this area.

The cut slope and fill slope are comprised of a mixture of vegetation and stone.

Areas adjacent to the access road do not appear to meet permanent stabilization requirements. Included with the NOT was an email explaining that the landowner would seed and mulch this area but regardless, it does not meet permanent stabilization requirements, therefore I recommend that this NOT be denied.

2613971 Primary Facility 2017-07-10 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 13:55p.m.

The cellar was full of gravel and there was no gas detected at the perimeter of the cellar. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure with a Crystal pressure gauge. There was 205psi on the production casing and 166psi on the production line. I took a walk around the location and there were no obvious concerns noticed. I left the site at 14:25p.m.

2716363 Primary Facility 2018-04-09 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was full of gravel and dirt, I was unable to check for gas at the perimeter of the cellar because the ground was frozen. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2818055 Primary Facility 2018-12-20 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was shut in at the GPU. The cellar was full of gravel and was unable to check for gas at the perimeter of the cellar because the gravel was frozen. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1916793 596319 09/29/2010 2010-09-29 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days Administrative Viols response rec'vd 10/7/2010. Gas well completions report ultimately reviewed 10/29/12. Related follow-up insp 2/28/13 found no viols.
1916793 596320 09/29/2010 2010-09-29 78.66A - Failure to report release of substance threatening or causing pollution Administrative Viols response rec'vd 10/7/2010. Gas well completions report ultimately reviewed 10/29/12. Related follow-up insp 2/28/13 found no viols. Failure to Report bubbling gas from btw. 13-3/8" and 9-5/8". Small leak could have been missed by operator.

For data sources see[8]

References