If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-20211 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.877746,"lon":-75.887918,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Bridgewater Township | |
Operator Name: SWN PROD CO LLC | |
Well Pad ID: 149668 | |
Farm/Lease Name: MARKOVITCH 1H | |
License Status: | |
Spud Date: | |
Permit Date: 2009-09-03 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.877746 | |
Longitude: -75.887918 |
Date | Event |
---|---|
2009-09-03 | New Permit Application |
2009-09-16 | Performed Spud Operation |
2009-10-24 | Drilling Completion |
2009-11-30 | DEVIATED |
2010-01-13 | Perforation |
2010-01-13 | Performed Stimulation |
For data sources see[4]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2010-01-13 | 0 | 0 | 0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2009 | ALTA OPR CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2010 | XPR RESOURCES LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | XPR RESOURCES LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | XPR RESOURCES LLC | 202,502.29 | 127 | 0.00 | 0 | 0.00 | 0 |
2013 | XPR RESOURCES LLC | 372,603.80 | 359 | 0.00 | 0 | 0.00 | 0 |
2014 | XPR RESOURCES LLC | 312,163.11 | 353 | 0.00 | 0 | 0.00 | 0 |
2015 | SWN PROD CO LLC | 262,281.14 | 364 | 0.00 | 0 | 0.00 | 0 |
2016 | SWN PROD CO LLC | 225,883.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | SWN PROD CO LLC | 187,051.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | SWN PROD CO LLC | 155,002.00 | 363 | 0.00 | 0 | 0.00 | 0 |
2019 | SWN PROD CO LLC | 144,650.00 | 360 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | XPR RESOURCES LLC | Produced Fluid | 113.56 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW018 |
2013 | XPR RESOURCES LLC | Produced Fluid | 1,249.45 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2013 | XPR RESOURCES LLC | Produced Fluid | 205.19 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW018 |
2013 | XPR RESOURCES LLC | Produced Fluid | 817.49 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2013 | XPR RESOURCES LLC | Produced Fluid | 291.17 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2013 | XPR RESOURCES LLC | Produced Fluid | 109.21 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW018 |
2013 | XPR RESOURCES LLC | Produced Fluid | 263.86 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2013 | XPR RESOURCES LLC | Produced Fluid | 199.57 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
2013 | XPR RESOURCES LLC | Produced Fluid | 742.75 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NC010 |
2014 | XPR RESOURCES LLC | Produced Fluid | 210.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2014 | XPR RESOURCES LLC | Produced Fluid | 163.90 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2014 | XPR RESOURCES LLC | Produced Fluid | 424.95 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2014 | XPR RESOURCES LLC | Produced Fluid | 2,687.55 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015 | SOUTHWESTERN ENERGY PROD CO | Produced Fluid | 2,689.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SWN PROD CO LLC | Produced Fluid | 1,118.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2016 | SWN PROD CO LLC | Produced Fluid | 1,465.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | SWN PROD CO LLC | Produced Fluid | 2,473.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017 | SWN PROD CO LLC | Other Oil & Gas Wastes | 3.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017 | SWN PROD CO LLC | Produced Fluid | 215.00 Bbl | REUSE (AT WELL PAD) | |
2017 | SWN PROD CO LLC | Produced Fluid | 110.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2018 | SWN PROD CO LLC | Produced Fluid | 1,220.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018 | SWN PROD CO LLC | Produced Fluid | 674.00 Bbl | REUSE (AT WELL PAD) | |
2018 | SWN PROD CO LLC | Produced Fluid | 336.00 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 370.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019 | SWN PROD CO LLC | Produced Fluid | 110.00 Bbl | REUSE (AT WELL PAD) | |
2019 | SWN PROD CO LLC | Produced Fluid | 548.00 Bbl | SURFACE IMPOUNDMENT | 826342 |
2019 | SWN PROD CO LLC | Other Oil & Gas Wastes | 131.74 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019 | SWN PROD CO LLC | Produced Fluid | 1,009.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1852643 | Primary Facility | 2009-12-03 | Routine/Complete Inspection | No Violations Noted | |
1860519 | Primary Facility | 2010-01-22 | Drilling/Alteration | Violation(s) Noted | At the time of inspection, well was being flared. Well was on third day of flaring and was expected to be flared for several additional days. While driving up the access road to the well pad, I observed an area where black fluid resembling drilling mud appeared to have been spilled onto the ground. It was evident that the black fluid migrated downhill approximately 200 feet in the drainage ditch of the access road. I took several pictures of the spill, and notified Alta of the incident. At approximately 2:00, I met with Joe Hill of Alta at the site and identified the area of concern to him. He indicated he was not aware of the spilled fluid or how the incident occurred. Mr. Hill stated that he would have his contractor on site start scraping up the impacted soils immediately and would collect pre and post remediation soil samples. |
2200449 | Primary Facility | 2013-08-30 | Routine/Complete Inspection | No Violations Noted | |
2200653 | Primary Facility | 2013-09-02 | Administrative/File Review | No Violations Noted | Reviewed Inspection Reports for 7/2/2012 thru 5/21/2013. |
2363220 | Primary Facility | 2015-04-21 | Routine/Complete Inspection | Pending | On 4/21/2015 the Department was on site to conduct a routine full inspection of the Markovitch Well Pad. |
2368975 | Primary Facility | 2015-05-12 | Routine/Complete Inspection | No Violations Noted | |
2433311 | Primary Facility | 2015-12-16 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 12:35 p.m., the cellar was full of gravel with water at the perimeter of the well with no bubbling observed, the vent pipe was open and set up with a Taylor plug, there was 324psi on the production casing and 205psi on the production line. I took a walk around the location and everything looked OK. |
2466750 | Primary Facility | 2016-03-17 | Routine/Complete Inspection | No Violations Noted | On 3/17/2016 the Department was on site to conduct a routine full inspection of the Markovitch Well Pad. The ESX number for this site is ESX11-115-0104.
The wells associated with this site are as follows: The 115-20211, 115-21388, 115-21875. The area along the roadway that was repaired last year is holding up well. The landowner has been skidding logs alongside the roadway, but no impact to the site or access road has been observed. There were no erosion and sedimentation problems, and the vegetation covering the site seems adequate. The site is stable and there were no issues at this time. There were no violations.
If there are any questions please feel free to contact me. |
2493516 | Primary Facility | 2016-06-13 | Incident- Response to Accident or Event | Viol(s) Noted & Immediately Corrected | Inspection of the Range 84 Markovitch Well Pad in response to a spill report by the operator. The incident occurred on Friday, June 10, 2016 at approximately 8:30 p.m. Initially, the spill was reported to Southwestern Energy (SWN) by the carrier as less than 5-gallons and clean-up began. A visual inspection by SWN personnel on the morning of Saturday, June 11th revealed the spill may have been more than initially thought and the spill was reported to DEP NERO's Emergency Response at 9:00 a.m. The information reached the Scranton O&G office at 9:00 a.m. on June 13, 2016. I spoke to SWN's Afton Sterling via telephone while on-site to obtain the details of the spill. I also received follow-up emails from SWN’s Mike Deming that relayed some other details of the incident. A summary of both sources indicates that a waste water truck was in the process of loading production water from the production tank on the pad when the production fluid foamed in the truck and spilled over. The process was halted and clean up b |
2520022 | Primary Facility | 2016-08-31 | Routine/Partial Inspection | No Violations Noted | |
2534048 | Primary Facility | 2016-11-02 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 13:00p.m., the cellar was full of gravel with water on top and no bubbling noticed. The vent pipe was open and set up with a Taylor plug to check for pressure. There was 217psi on the production casing and 147psi on the production line. I took a walk around the location and there were no obvious concerns noticed.
I left the site at 13:15p.m. |
2568238 | Primary Facility | 2017-03-07 | Routine/Complete Inspection | No Violations Noted | Logs from forestry operation outside lod being staged just outside access road. No impact to access road observed. There are no erosion issues apparent on site at this time.
There are no volations If there are any questions contact me at 570-346-5539 |
2622715 | Primary Facility | 2017-08-03 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 14:10p.m.
The cellar was set up with a plastic corrugated pipe around the well for inspection access; there was cement between the (20x13) and (13x9) annuli with no gas detected. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure with a Crystal pressure gauge. I took a walk around the location and there were no obvious concerns noticed. I left the site at 14:35p.m. |
2730107 | Primary Facility | 2018-05-15 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. The cellar was set up with a corrugated pipe around the well for inspection access. The (20x13) annulus was below the water level and there was no bubbling noticed. There was cement between the (13x9) annulus and there was no gas detected. There was an 1100 gallon tank on containment with 70% non-potable water and 30% methanol, the containment appeared to be in good condition. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2753517 | Primary Facility | 2018-07-12 | Routine/Complete Inspection | No Violations Noted | I inspected the Markovitch well pad on July 12, 2018. The well on site was the 115-20211. It was properly labeled.
The access road was solid and stable. The pad surface was as well. The cut and fill slopes were vegetated and stable with no erosional issues apparent. There were no violations noted. |
2830957 | Primary Facility | 2019-01-24 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. The cellar was set up with a plastic corrugated pipe around the well for inspection access. There was water 3' below grade in the cellar with no bubbling noticed and there was no gas detected in the remainder of the cellar with a MSA Altair 5X multi gas detector that was calibrated on 1/2/19. There was a 1100 gallon tank on containment and the containment appeared to be in good condition (see photo #3). I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1860519 | 580629 | 01/22/2010 | 2010-01-22 | 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used | Administrative | Site cleaned up |
2493516 | 761581 | 2016-06-13 | CSL 402(b) | Environmental Health & Safety | ||
2493516 | 761582 | 2016-06-13 | 78.56(a) | Environmental Health & Safety | ||
2493516 | 761583 | 2016-06-13 | SWMA301 | Environmental Health & Safety | ||
2493516 | 761585 | 2016-06-13 | OGA3218.2(A) | Environmental Health & Safety |