If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-20401 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.782742,"lon":-75.965458,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Jessup Township | |
Operator Name: CABOT OIL & GAS CORP | |
Well Pad ID: 148623 | |
Farm/Lease Name: JOSEPH BLAISURE 5 | |
License Status: | |
Spud Date: | |
Permit Date: 2010-07-27 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.782742 | |
Longitude: -75.965458 |
Date | Event |
---|---|
2010-07-27 | New Permit Application |
2010-08-13 | Performed Spud Operation |
2010-12-05 | Drilling Completion |
2010-12-16 | Perforation |
2010-12-16 | Performed Stimulation |
2011-11-09 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2011-05-24 | 2011-05-24 | 6,601 | 5,567,814 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | 15 HCl | BJ Services Company | Acid Package | Hydrochloric acid | 7647-01-0 | 15.00 | 0.08 | |
Alpha 1427 | BJ Services Company | Antibacterial Agent | Quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides |
68424-85-1 | 7.00 | 0.00159000 | ||
Ethanol | 64-17-5 | 5.00 | 0.00113000 | |||||
Didecyl dimethyl ammonium chloride | 7173-51-5 | 10.00 | 0.00226000 | |||||
Glutaraldehyde | 111-30-8 | 30.00 | 0.00679000 | |||||
Water | Carrier/Base Fluid | 100.00 | 88.30 | |||||
Clay Master-5C | BJ Services Company | Clay Stabilization | No hazardous ingredients | 0.00058000 | ||||
FRW-18 | BJ Services Company | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.02 | ||
Ferrotrol 300L | BJ Services Company | Iron Control Product | Citric acid | 77-92-9 | 70.00 | 0.00088000 | ||
CI-14 | BJ Services Company | Corrosion Inhibitor | Propargyl alcohol | 5.00 | 0.00004000 | |||
Methanol | 67-56-1 | 68.00 | 0.00059000 | |||||
Scaletrol 720 | BJ Services Company | Scale Inhibitor | Diethylene glycol | 111-46-6 | 5.00 | 0.00052000 | ||
Ethylene glycol | 107-21-1 | 35.00 | 0.00362000 | |||||
Sand (Proppant) | Proppant | 100.00 | 11.56 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2010-12-16 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | CABOT OIL & GAS CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | CABOT OIL & GAS CORP | 573,031.03 | 138 | 0.00 | 0 | 0.00 | 0 |
2012 | CABOT OIL & GAS CORP | 1,123,434.83 | 365 | 0.00 | 0 | 0.00 | 0 |
2013 | CABOT OIL & GAS CORP | 617,521.59 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | CABOT OIL & GAS CORP | 670,299.21 | 359 | 0.00 | 0 | 0.00 | 0 |
2015 | CABOT OIL & GAS CORP | 200,676.81 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CABOT OIL & GAS CORP | 464,061.91 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CABOT OIL & GAS CORP | 370,100.55 | 361 | 0.00 | 0 | 0.00 | 0 |
2018 | CABOT OIL & GAS CORP | 295,547.00 | 364 | 0.00 | 0 | 0.00 | 0 |
2019 | CABOT OIL & GAS CORP | 269,647.00 | 357 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2010 | CABOT OIL & GAS CORP | Basic Sediment | 2.96 Bbl | LANDFILL | 101534 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 181.50 Tons | LANDFILL | THR029 |
2010 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 238.20 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 72.10 Tons | LANDFILL | 101247 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 20.40 Tons | LANDFILL | NY # 50S08 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 117.40 Tons | LANDFILL | NY # 02S17 |
2010 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 143.40 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 553.50 Tons | LANDFILL | 100955 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 117.40 Tons | LANDFILL | 8-4630-00010/00 |
2011 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 903.69 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | CABOT OIL & GAS CORP | Drill Cuttings | 4.03 Tons | LANDFILL | 101247 |
2011 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 11.67 Bbl | LANDFILL | 100955 |
2011 | CABOT OIL & GAS CORP | Basic Sediment | 3.52 Bbl | LANDFILL | 101534 |
2011 | CABOT OIL & GAS CORP | Drill Cuttings | 1.78 Tons | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PAD014286009 |
2011 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 9.42 Bbl | LANDFILL | 301626 |
2011 | CABOT OIL & GAS CORP | Produced Fluid | 1,612.41 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | CABOT OIL & GAS CORP | Drill Cuttings | 1.06 Tons | LANDFILL | 101534 |
2011 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 11,047.25 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | CABOT OIL & GAS CORP | Drill Cuttings | 54.57 Tons | LANDFILL | THR029 |
2011 | CABOT OIL & GAS CORP | Drill Cuttings | 1.44 Tons | LANDFILL | 100081 |
2011 | CABOT OIL & GAS CORP | Drill Cuttings | 23.81 Tons | LANDFILL | 100945 |
2011 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 5.04 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | |
2011 | CABOT OIL & GAS CORP | Fracturing Fluid Waste | 17.48 Tons | LANDFILL | 101534 |
2011 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 1.32 Bbl | LANDFILL | 301626 |
2011 | CABOT OIL & GAS CORP | Basic Sediment | 13.56 Bbl | LANDFILL | 100081 |
2011 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 6.87 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PAD014286009 |
2011 | CABOT OIL & GAS CORP | Drill Cuttings | 4.35 Tons | LANDFILL | 132310 |
2012 | CABOT OIL & GAS CORP | Basic Sediment | 3.74 Bbl | LANDFILL | THR029 |
2012 | CABOT OIL & GAS CORP | Basic Sediment | 7.82 Bbl | LANDFILL | 100081 |
2012 | CABOT OIL & GAS CORP | Basic Sediment | 8.02 Bbl | LANDFILL | 101534 |
2012 | CABOT OIL & GAS CORP | Produced Fluid | 1,653.25 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CABOT OIL & GAS CORP | Produced Fluid | 277.31 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2013 | CABOT OIL & GAS CORP | Produced Fluid | 314.38 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NE002 |
2014 | CABOT OIL & GAS CORP | Produced Fluid | 916.17 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015 | CABOT OIL & GAS CORP | Produced Fluid | 209.91 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 140.72 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 269.74 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2017 | CABOT OIL & GAS CORP | Waste Water Treatment Sludge | 1.97 Tons | REUSE (AT WELL PAD) | |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 122.64 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 99.22 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 200.42 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 66.42 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2019 | CABOT OIL & GAS CORP | Produced Fluid | 350.40 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1934071 | Primary Facility | 2010-11-23 | Drilling/Alteration | No Violations Noted | Patterson 538. David Blood - Company man. Drilling depth 3729'. Drilling on air to kick off point. Drillers log on site and up to date. All equipment on secondary containment. Reported 83 bbls return on 13 3/8" which was set at 578'. Reported 32 bls returns on 9 5/8" which is set at 1578'. |
2054291 | Primary Facility | 2012-03-22 | Routine/Complete Inspection | No Violations Noted | |
2366120 | Primary Facility | 2015-05-01 | Routine/Complete Inspection | No Violations Noted | |
2467360 | Primary Facility | 2016-03-23 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 11:15 a.m., the cellar was about half full of water with no bubbling noticed, the (13x9) vent pipe was open and venting to a tank, the (9x5) vent pipe was open and venting to a tank, there was 647psi on the production casing. I took a walk around the location and everything looked OK.
I left the site at 12:25 a.m. |
2517055 | Primary Facility | 2016-08-31 | Site Restoration | No Violations Noted | The Department was on site to conduct a Notice of Termination (NOT) for the Joseph Blaisure Pad 1 well site (Erosion and sediment permit 58-09-802). The wells associated with this site are as follows:
115-20401
There were no violations I recommend approval of the NOT for this site. If there are any questions please feel free to contact me at (570) 346-5539 |
2548711 | Primary Facility | 2016-12-22 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 12:30p.m., the cellar was about half full of ice and water with no bubbling noticed. The (13x9) vent pipe was open and venting into the production tank, the (9x7) vent pipe was open and venting into the production tank. There was 562psi on the production casing. I took a walk around the location and there were no obvious concerns noticed.
I left the site at 13:15p.m. |
2636141 | Primary Facility | 2017-09-14 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. All the annuli vent pipes were connected together and venting into the same tank. I took a walk around the location and there were no obvious concerns noticed. |
2728169 | Primary Facility | 2018-05-08 | Routine/Complete Inspection | No Violations Noted | I performed a RTNC inspection for the Jo Blaisure pad. The wells associated with this pad are as follows: 115-20239, 115-20245, 115-20399, 115-20400, 115-20401. The wells were all properly labeled.
The access road and pad surface were solid and stable with no erosional issues. The cut and fill slopes were stable and well vegetated and were greening up nicely. There did not appear to be any erosional issues. There were no violations noted. |
2743783 | Primary Facility | 2018-06-20 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was gas detected at the poly vent tank at 100% LEL and 100% methane. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2838590 | Primary Facility | 2019-02-11 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. There was ice 2' below grade in the cellar and I was unable to check for gas. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was gas detected at the poly vent tank with a MSA Altair 5X multi gas detector that was calibrated on 2/5/19. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
For data sources see[9]