If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-20428 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.671611,"lon":-75.855528,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Springville Township | |
Operator Name: CHIEF OIL & GAS LLC | |
Well Pad ID: 149338 | |
Farm/Lease Name: SQUIER UNIT 2H | |
License Status: | |
Spud Date: | |
Permit Date: 2010-08-13 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.671611 | |
Longitude: -75.855528 |
Date | Event |
---|---|
2010-08-13 | New Permit Application |
2010-10-08 | Performed Spud Operation |
2010-11-05 | Drilling Completion |
2012-05-07 | Perforation |
2012-05-10 | Performed Stimulation |
2013-05-23 | DEVIATED |
2016-02-03 | Perforation |
2016-02-03 | Performed Stimulation |
2016-02-20 | Drilling Completion |
2016-05-12 | REWORKED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-05-10 | 2012-05-10 | 7,582 | 3,750,096 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | FRW-600 | Frac Tech Services (FTS) | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 0.07 | ||
Hydrochloric Acid 15 | Frac Tech Services (FTS) | Acid | Water | 7732-18-5 | ||||
Hydrochloric acid | 7647-01-0 | 0.64 | ||||||
Scale Inhibitor - Gyptron T-390 | Champion Technologies | Scale Inhibitor | ||||||
Methanol | 67-56-1 | 0.00900000 | ||||||
Fresh Water | Base Fluid | |||||||
Fresh Water | 100.00 | 77.04 | ||||||
Sand (Proppant) | Frac Tech Services (FTS) | Propping Agent | Quartz | 14808-60-7 | 99.90 | 22.19 | ||
Biocide - Bactron K 139 | Champion Technologies | Biocide | Quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides |
68424-85-1 | ||||
Ethanol | 64-17-5 | |||||||
Glutaraldehyde | 111-30-8 | 0.03 | ||||||
benzyl-C12-16 alkyldimethyl,chlorides |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2016-02-03 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CHIEF OIL & GAS LLC | 1,182,020.49 | 188 | 0.00 | 0 | 0.00 | 0 |
2013 | CHIEF OIL & GAS LLC | 1,374,030.00 | 360 | 0.00 | 0 | 0.00 | 0 |
2014 | CHIEF OIL & GAS LLC | 667,461.00 | 359 | 0.00 | 0 | 0.00 | 0 |
2015 | CHIEF OIL & GAS LLC | 505,998.62 | 320 | 0.00 | 0 | 0.00 | 0 |
2016 | CHIEF OIL & GAS LLC | 304,758.08 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CHIEF OIL & GAS LLC | 470,917.06 | 364 | 0.00 | 0 | 0.00 | 0 |
2018 | CHIEF OIL & GAS LLC | 307,087.19 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CHIEF OIL & GAS LLC | 296,151.48 | 323 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2010 | CHIEF OIL & GAS LLC | Drilling Fluid Waste | 833.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0008451 |
2012 | CHIEF OIL & GAS LLC | Produced Fluid | 1,974.30 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CHIEF OIL & GAS LLC | Produced Fluid | 439.60 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CHIEF OIL & GAS LLC | Produced Fluid | 87.40 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | CHIEF OIL & GAS LLC | Produced Fluid | 32.40 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CHIEF OIL & GAS LLC | Produced Fluid | 29.22 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | CHIEF OIL & GAS LLC | Produced Fluid | 16.55 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2019 | CHIEF OIL & GAS LLC | Produced Fluid | 5.73 Tons | LANDFILL | 301358 |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1924128 | Primary Facility | 2010-10-27 | Follow-up Inspection | Viol(s) Noted & Immediately Corrected | Patterson 251. Reported spill of water-based mud due to gas bubble while drilling. Mud sprayed off location due to discharge hose being blocked with cement. Hose bucked and sprayed off pad. Hose was not chained down. Area impacted approximately 30 x30'. Excavated top 6" of soil from area and place soils in rolloff container for T&D. Reported @5gallon overspray. Majority of mud contained on plastic on site. Violation immediately corrected. |
1973719 | Primary Facility | 2011-05-13 | Routine/Complete Inspection | No Violations Noted | |
2035230 | Primary Facility | 2012-01-17 | Routine/Complete Inspection | No Violations Noted | |
2062244 | Primary Facility | 2012-04-17 | Incident- Response to Accident or Event | No Violations Noted | |
2316776 | Primary Facility | 2014-10-16 | Complaint Inspection | Pending | |
2549605 | Primary Facility | 2016-01-04 | Routine/Partial Inspection | No Violations Noted | |
2737084 | Primary Facility | 2018-04-17 | Follow-up Inspection | No Violations Noted | The Department was on site to meet with representatives of Chief Oil & Gas to conduct a Follow Up Inspection to the Department's 4/17/2012 inspection which was conducted in response to a self-reported and assumed vandalism incident causing the release of an approximate 500 bbl. of what was reported to be freshwater to the pad's surface. During the inspection conductivity screening revealed elevated readings in the perimeter ditch (Collection Ditch #1) and sediment trap below the location of the release. Additionally, dead amphibians were found within the confines of said sediment trap. A copy of the sample collected during the 4/17/2012 inspection is attached for your reference.
During this inspection, Eric Rooney (DEP-PG) and I met with Mike Walor (Woodard and Curran-Scientist) and Kellon Balum (Chief). At this time, Mr. Walor began to use an auger and a shovel to reach a depth of approximately 28" so that samples collected would be from the base of the sediment trap. The material was soft and water |
2822315 | Primary Facility | 2018-12-26 | Routine/Complete Inspection | No Violations Noted | I arrived on site at 1450 to perform a site restoration inspection.
After performing an administrative review of the plan and a site inspection, I do not agree that site conditions meet the requirements for the termination of this permit. Namely, the site did not meet 70 percent vegetative cover stabilization requirements for permit termination, and the footprint restored pad did not match the site plan. No violations were noted. |
2822872 | Primary Facility | 2018-12-26 | Routine/Complete Inspection | No Violations Noted | I arrived on site at 1450 to perform a site restoration inspection.
After performing an administrative review of the plan and a site inspection, I do not agree that site conditions meet the requirements for the termination of this permit. Namely, the site did not meet the 70 percent perennial vegetative cover stabilization requirements for permit termination, and the footprint of the restored pad did not match the site plan. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1924128 | 598381 | 10/27/2010 | 2010-10-27 | 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation. | Administrative |
For data sources see[9]