37-115-20461

Well Details

Well ID: 37-115-20461
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Franklin Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 148221
Farm/Lease Name: DEPUE 8H
License Status:
Spud Date:
Permit Date: 2010-11-09
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.924375
Longitude: -75.8729

For data sources see[1][2][3]

Well History

Date Event
2010-11-09 New Permit Application
2010-11-18 Performed Spud Operation
2011-03-10 Drilling Completion
2011-09-17 Perforation
2011-09-17 Performed Stimulation
2012-04-30 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-09-23 2011-09-23 5,901 5,040,726

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 SP Breaker Halliburton Energy Services Breaker Sodium persulfate 7775-27-1 100.00 0.00053000
WG-36 Gelling Agent Halliburton Energy Services Gel Guar gum 9000-30-0 100.00 0.00219000
GBW-30 Breaker Halliburton Energy Services Breaker
Hemicellulase enzyme 9012-54-8 15.00 0.00008000
Carbohydrates 95.00 0.00050000
Water Carrier/Base Fluid Water 100.00 83.41
Sand- Silica Sand Halliburton Energy Services Proppant Quartz 14808-60-7 100.00 16.40
LP-65 Halliburton Energy Services Scale Inhibitor Ammonium chloride 12125-02-9 10.00 0.00346000
Hydrochloric Acid Halliburton Energy Services Acid Hydrochloric acid 7647-01-0 30.00 0.12
BE-9M Halliburton Energy Services Biocide
Tri-n-butyl tetradecyl phosphonium chloride 81741-28-8 10.00 0.00183000
Methanol 67-56-1 30.00 0.00548000
FR-66 Friction Reducer Halliburton Energy Services Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.01
Cla-Web Halliburton Energy Services Clay Control Proprietary 60.00 0.02

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2011-09-17 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 XPR RESOURCES LLC 0.00 0 0.00 0 0.00 0
2011 XPR RESOURCES LLC 0.00 0 0.00 0 0.00 0
2012 XPR RESOURCES LLC 746,731.83 343 0.00 0 0.00 0
2013 XPR RESOURCES LLC 726,649.21 365 0.00 0 0.00 0
2014 XPR RESOURCES LLC 501,265.65 364 0.00 0 0.00 0
2015 SWN PROD CO LLC 325,365.83 362 0.00 0 0.00 0
2016 SWN PROD CO LLC 313,471.00 365 0.00 0 0.00 0
2017 SWN PROD CO LLC 262,363.00 363 0.00 0 0.00 0
2018 SWN PROD CO LLC 189,967.00 342 0.00 0 0.00 0
2019 SWN PROD CO LLC 161,418.00 359 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 XPR RESOURCES LLC Drilling Fluid Waste 7,143.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0008451
2011 XPR RESOURCES LLC Drilling Fluid Waste 340.64 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PAD014286009
2012 XPR RESOURCES LLC Fracing Fluid Waste 192.50 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC006
2013 XPR RESOURCES LLC Produced Fluid 200.17 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2013 XPR RESOURCES LLC Produced Fluid 1,274.43 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013 XPR RESOURCES LLC Produced Fluid 820.06 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2013 XPR RESOURCES LLC Produced Fluid 520.62 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2013 XPR RESOURCES LLC Produced Fluid 947.21 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2013 XPR RESOURCES LLC Produced Fluid 543.91 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC010
2013 XPR RESOURCES LLC Produced Fluid 620.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2014 XPR RESOURCES LLC Produced Fluid 406.19 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2014 XPR RESOURCES LLC Produced Fluid 1,664.76 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2014 XPR RESOURCES LLC Produced Fluid 933.51 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014 XPR RESOURCES LLC Produced Fluid 1,327.83 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 SOUTHWESTERN ENERGY PROD CO Produced Fluid 1,994.25 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Produced Fluid 725.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016 SWN PROD CO LLC Produced Fluid 214.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2016 SWN PROD CO LLC Spent Lubricant Waste 10.00 Bbl RESIDUAL WASTE TRANSFER FACILITY 101532
2016 SWN PROD CO LLC Produced Fluid 2,587.75 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWN PROD CO LLC Other Oil & Gas Wastes 4.50 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Produced Fluid 3,120.42 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Produced Fluid 385.00 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Other Oil & Gas Wastes 30.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Produced Fluid 621.67 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Produced Fluid 669.01 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Produced Fluid 1,862.67 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Other Oil & Gas Wastes 16.67 Bbl REUSE (AT WELL PAD)
2019 SWN PROD CO LLC Produced Fluid 874.68 Bbl SURFACE IMPOUNDMENT 826342
2019 SWN PROD CO LLC Produced Fluid 69.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC035
2019 SWN PROD CO LLC Produced Fluid 1,662.34 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Other Oil & Gas Wastes 7.25 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 176.11 Bbl REUSE (AT WELL PAD)

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1942790 Primary Facility 2011-01-05 Routine/Complete Inspection No Violations Noted
1950413 Primary Facility 2011-02-15 Drilling/Alteration Pending Brad Thompson Company Man. Pioneer 60. Trippin gout of hole to pick up another set of jars. Fish stuck at 4000'. Were drilling on air, and will be switching over to synthetic. Proposed TD=10,993'. Walked site with Co. Man. Drillers log on site and up to date. Observed bubbling in cellar. Having cellar pumped down while on site. Observed bubbling in between 13 3/8" x 9 5/8" casings. Minor consistent bubbling on one side of casing. Discussed with Co. Man to monitor and DEP will follow up on issue.
1950415 Primary Facility 2011-02-15 Follow-up Inspection Violation(s) Noted BAsed on earlier inspection of the site, bubbling was observed in the cellar of the well. The bubbling identified was detemined to be between 13 3/8" x 9 5/8" annulus. Violation cited= Defective casing/cement job on intermediate casing string. Operator has 30 days to respond with plan or fix the defect. DEP will follow up. GMI closed 4/24/13 via non-impact determ ltr.
1954842 Primary Facility 2011-03-04 Follow-up Inspection Violation(s) Noted FUI on reported spill of drilling mud. Ocurred on 2/17/11. Reported on 3/3/11. Ovrfilled hole with mud and spilled out of BOP onto plastic and into cellar. Crews on site sucking up mud and cleaning area. Reprtedly lost 10 bbls of fluid. Inspected cellar. bubling still present arond base of well. DEP will be returning to site to sample for gas around well head next week.
1959370 Primary Facility 2011-03-11 Routine/Complete Inspection No Violations Noted See inspection# 1959348 for violations
1959391 Primary Facility 2011-03-15 Routine/Complete Inspection No Violations Noted
1974964 Primary Facility 2011-05-11 Routine/Complete Inspection Pending At time of inspection crews on site cleaning up pad-removing plastic and scraping pad. Observed bubbling at well head in between 9 x 13 3/8" annulus and 13 3/8" x 16" annulus. Further investigation will be performed by DEP to confirm source of bubbling. Rathole not filled in. Met Williams rep. on site who informed DEP that rathole will be filled in within next day or so. DEP will follow up.
2000370 Primary Facility 2011-08-24 Drilling/Alteration No Violations Noted Ziegenfuss on site. Preparing to set 7" casing as conductor to @ 60'. Then drilling to just below 13 3/8" to perform squeeze. Have gauge on 9 5/8" x 5 1/2". Reading @ 100 psi. Have drilled 15' of hole. Drilling on air with hammer hole 1/2' from well on south side. Cellar full of water. Bubbling present. Ran Gyro and Noise log. Will drill to a depth of 477' then run image log and triple combo.
2000371 Primary Facility 2011-08-25 Drilling/Alteration No Violations Noted Ran logs. Reviewing logs today to determine where any gas shows might exist. Will run another noise log down further on 8H to 4200' in 5 1/2". Will run gyro on test hole and then cement tomorrow.
2026419 Primary Facility 2011-12-08 Routine/Complete Inspection No Violations Noted Please refer to Depue 2H 12-8-11 inspection report for comments. Permit number is 115-20418.
2027758 Primary Facility 2011-12-12 Follow-up Inspection No Violations Noted arrived at the site at 13:00. R&T Oilfield Services Inc. was on-site and in the process of filtering frac flowback fluid related to the OG-71 I approved of. I spoke with Jason Ridgeway and Zach Cook of R&T regarding the filtering operation. Gas flaring at the site still on-going as observed in the 12-8-11 inspection.
2053535 Primary Facility 2012-03-20 Routine/Complete Inspection Pending Well is online. Observed bubbling on 9 x 1 3/8" annulus.Bubbling is conistent. No other bubbling was observed at time of this inspection. There was no activity on site.
2066964 Primary Facility 2012-05-10 Drilling/Alteration No Violations Noted Routine Inspection of well condition. Well is online. Gauge on production string @ 750 psi. Intermittent bubbling observed between 9 x 13 3/8" casings. No activity on site.
2363011 Primary Facility 2015-04-20 Routine/Complete Inspection No Violations Noted
2434500 Primary Facility 2015-12-21 Routine/Complete Inspection Violation(s) Noted At time of inspection, arrived on site at 9:15 a.m., a crew was on site plugging the 6H, the cellar was full of water, the (13x9) vent pipe was open and venting into the atmosphere with gas detected at 100% LEL and 15% methane, the (9x5) vent pipe was open and set up with a Taylor plug, there was 310psi on the production casing and the valves were closed on the production line while the 6H was being plugged. I took a walk around the location and everything looked OK.
2530421 Primary Facility 2016-10-20 Routine/Complete Inspection Outstanding Violations - No Viols Req'd At time of inspection, arrived on site at 12:45p.m., the cellar was full of water with no bubbling noticed. The (13x9) vent pipe was open and venting into the atmosphere with gas detected at 100% LEL and peaked at 13% methane with no measurable flow. The (9x5) vent pipe was open and set up with a Taylor plug to check for pressure. There was 225psi on the production casing and 181psi on the production line. I took a walk around the location and there were no obvious concerns noticed.

I left the site at 13:35p.m.

2619644 Primary Facility 2017-07-26 Routine/Complete Inspection Outstanding Violations - Viols Req'd At time of inspection, arrived on site at 13:40p.m.

The cellar was full of water with no bubbling noticed. The (13x9) annulus vent pipe was open and venting into the atmosphere with gas detected at 100% LEL and peaked at 16% methane. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure with a Crystal pressure gauge and a 2000psi pressure gauge with about 70psi on it. There was 216psi on the production casing and 168psi on the production line. I took a walk around the location and there were no obvious concerns noticed. I left the site at 14:35p.m.

2727566 Primary Facility 2018-05-08 Routine/Complete Inspection Outstanding Violations - Viols Req'd At time of inspection.

The well was in production. There was water 0' below grade in the cellar and there was no bubbling noticed. The (13x9) annulus was venting into the atmosphere with gas detected at 100% LEL and 15% methane with no measurable flow. There were two 2100 gallon tanks labeled 70% Non Potable Water and 30% methanol on containment and the containment appeared to be in good condition. I took a walk around the location and there were no obvious concerns noticed.

2826604 Primary Facility 2019-01-14 Routine/Complete Inspection Outstanding Violations - Viols Req'd At time of inspection.

The well was shut in at the GPU by a pneumatic valve. The cellar was full of ice. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1950415 604972 02/15/2011 2011-02-15 78.86* - Failure to report defective, insufficient, or improperly cemented casing w/in 24 hrs or submit plan to correct w/in 30 days Administrative Gas well completions report ultimately reviewed 2/17/12. Related follow-up insp 5/10/12 found no viols. Integrity evaluation of gas well done 8/17-20/12 during GMI investigation found no viols. GMI closed 4/24/13 via non-impact determ ltr.
1954842 605918 03/04/2011 2011-03-04 91.33A - Failure to notify DEP of pollution incident. No phone call made forthwith Administrative
1954842 605919 03/04/2011 2011-03-04 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. Environmental Health & Safety
2434500 741716 12/21/2015 2015-12-21 78.86 - CASING AND CEMENTING - DEFECTIVE CASING OR CEMENTING - Operator failed to report defect in a well that has defective, insufficient or improperly cemented casing to the Department within 24 hours of discovery. Operator failed to correct defec Environmental Health & Safety
2619644 792539 2017-07-26 78a86 Environmental Health & Safety
2727566 817233 2015-12-21 78.86 Environmental Health & Safety Gas detected at the (13x9) annulus

Continuing violation

2826604 838911 2015-12-21 78.86 Environmental Health & Safety This is not a new violation.

This is an outstanding violation for gas detected at the (13x9) annulus.

For data sources see[9]