If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-20466 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.884172,"lon":-75.992253,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Forest Lake Township | |
Operator Name: BKV OPR LLC | |
Well Pad ID: 145322 | |
Farm/Lease Name: BAKER 6H | |
License Status: | |
Spud Date: | |
Permit Date: 2010-11-17 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.884172 | |
Longitude: -75.992253 |
Date | Event |
---|---|
2010-11-17 | New Permit Application |
2010-12-03 | Performed Spud Operation |
2011-06-02 | Drilling Completion |
2012-08-17 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-03-02 | 2012-03-02 | 6,238 | 3,828,468 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Sand, White, 100 | Baker Hughes | Proppant | Quartz | 14808-60-7 | 100.00 | 1.66 | |
Sand, White, 40/70 | Baker Hughes | Proppant | Quartz | 14808-60-7 | 100.00 | 7.57 | ||
Hydrochloric Acid 5.1-7.5 | Baker Hughes | Acidizing | Hydrochloric acid | 7647-01-0 | 7.50 | 0.05 | ||
Water | 7732-18-5 | 92.50 | 0.66 | |||||
InFlo 250W | Baker Hughes | Surfactant | 2-Butoxyethanol | 111-76-2 | 5.00 | 0.00003000 | ||
Methanol | 67-56-1 | 30.00 | 0.00018000 | |||||
Surfactants | 80.00 | 0.00049000 | ||||||
Sand, White, 30/50 | Baker Hughes | Proppant | Quartz | 14808-60-7 | 100.00 | 5.64 | ||
Ferrotrol 300L | Baker Hughes | Iron Control | Citric acid | 77-92-9 | 60.00 | 0.00140000 | ||
CI-14 | Baker Hughes | Corrosion Inhibitor | Methanol | 67-56-1 | 100.00 | 0.00054000 | ||
Fatty acids, tall-oil | 61790-12-3 | 10.00 | 0.00005000 | |||||
Propargyl alcohol | 107-19-7 | 5.00 | 0.00003000 | |||||
Ethoxylated C14-15 alcohols | 68951-67-7 | 30.00 | 0.00016000 | |||||
Alkenes, C>10 .alpha.- | 64743-02-8 | 5.00 | 0.00003000 | |||||
FRW-18 | Baker Hughes | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.02 | ||
Ingredients shown above are subject to 29 CFR 1910.1200(i) and appear on Material Safety Data Sheets (MSDS). Ingredients shown below are Non-MSDS. |
Baker Hughes | Surfactant | ||||||
Alpha 1427 | Baker Hughes | Biocide | Quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides |
68424-85-1 | 5.00 | 0.00120000 | ||
Didecyl dimethyl ammonium chloride | 7173-51-5 | 10.00 | 0.00240000 | |||||
Ethanol | 64-17-5 | 5.00 | 0.00120000 | |||||
Glutaraldehyde | 111-30-8 | 30.00 | 0.00721000 | |||||
Scaletrol 720 | Baker Hughes | Scale Inhibitor | Calcium chloride | 10043-52-4 | 5.00 | 0.00083000 | ||
Ethylene glycol | 107-21-1 | 30.00 | 0.00500000 | |||||
Ingredients shown above are subject to 29 CFR 1910.1200(i) and appear on Material Safety Data Sheets (MSDS). Ingredients shown below are Non-MSDS. |
Formalin | 50-00-0 | ||||||
Thiourea polymer | 68527-49-1 | |||||||
Salt | 0.00468800 | |||||||
Poly (acrylamide-co-acrylic acid) | 0.02 | |||||||
Hydrochloric acid | 7647-01-0 | |||||||
Sodium chloride | 7647-14-5 | 0.00000500 | ||||||
Potassium chloride | 7447-40-7 | 0.00000833 | ||||||
Sorbitan Monooleate | 0.00468800 | |||||||
Polyacrylate | 0.00333073 | |||||||
Ethoxylated Alcohol | 0.00187520 | |||||||
Water | 7732-18-5 | 0.07 | ||||||
mesh | Hughes | Proppant | ||||||
Water | Operator | Carrier | Water | 7732-18-5 | 100.00 | 84.24 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | CARRIZO (MARCELLUS) LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | CARRIZO (MARCELLUS) LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CARRIZO (MARCELLUS) LLC | 1,195,101.00 | 285 | 0.00 | 0 | 0.00 | 0 |
2013 | CARRIZO (MARCELLUS) LLC | 532,476.00 | 279 | 0.00 | 0 | 0.00 | 0 |
2014 | CARRIZO (MARCELLUS) LLC | 6,752.25 | 7 | 0.00 | 0 | 0.00 | 0 |
2015 | CARRIZO (MARCELLUS) LLC | 1,046,551.07 | 317 | 0.00 | 0 | 0.00 | 0 |
2016 | CARRIZO (MARCELLUS) LLC | 356,398.72 | 268 | 0.00 | 0 | 0.00 | 0 |
2017 | CARRIZO (MARCELLUS) LLC | 213,919.01 | 345 | 0.00 | 0 | 0.00 | 0 |
2018 | BKV OPR LLC | 132,164.78 | 363 | 0.00 | 0 | 0.00 | 0 |
2019 | BKV OPR LLC | 80,811.88 | 319 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | CARRIZO (MARCELLUS) LLC | Drilling Fluid Waste | 281.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0102784 |
2011 | CARRIZO (MARCELLUS) LLC | Drill Cuttings | 756.00 Tons | LANDFILL | THR029 |
2011 | CARRIZO (MARCELLUS) LLC | Drill Cuttings | 1,580.00 Tons | LANDFILL | NY STATE #32S11 |
2011 | CARRIZO (MARCELLUS) LLC | Drilling Fluid Waste | 1,290.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2012 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 13,356.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 222.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 215.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 147.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 735.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 805.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 227.99 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 151.72 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 207.31 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 600.17 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 1,620.50 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CARRIZO (MARCELLUS) LLC | Other Oil & Gas Wastes | 15.18 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 43.55 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 32.43 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 69.22 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 119.48 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 93.83 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 44.83 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 100.87 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 48.98 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 230.74 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 31.62 Bbl | REUSE (AT WELL PAD) | |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 113.04 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 9.28 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018 | BKV OPR LLC | Produced Fluid | 15.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2018 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 59.20 Bbl | REUSE (AT WELL PAD) | |
2018 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 199.60 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2019 | BKV OPR LLC | Produced Fluid | 15.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
2019 | BKV OPR LLC | Produced Fluid | 271.43 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2019 | BKV OPR LLC | Produced Fluid | 15.00 Bbl | REUSE (AT WELL PAD) | |
2019 | BKV OPR LLC | Produced Fluid | 75.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1976951 | Primary Facility | 2011-05-31 | Drilling/Alteration | No Violations Noted | nabors Rig MO5. Currently WOC trucks to cement 5 1/2 string. Rigging up to cement and should be doing that later this evening. containment in place. Excessive amount of drill mud on plastic containment near solids mixing area nd mud storage tanks. Recommended containment be cleaned to prevent material from reaching ground surface. Followed up on reported spill of 1 1/2 bbl of drill mud. Appears to have been contained on plastic. Operator in process of cleaning up spill. Spoke with Nabors Driling Mgr about keeping site cleaner. |
1985319 | Primary Facility | 2011-06-27 | Routine/Complete Inspection | Pending | Bubbling observed in cellar around outside of 9 5/8" casing. Operator to clean out cellar so source of bubbling can be better determined. |
2007327 | Primary Facility | 2011-09-29 | Routine/Complete Inspection | No Violations Noted | |
2014431 | Primary Facility | 2011-10-25 | Routine/Complete Inspection | Pending | DEP arrived on site at 11 am. The purpose of the inspection was to check the status of the wells and not any activity on site. At the time of inspection, crews were installing new plastic secondary containment for upcoming frac. Six wells have been drilled (1H - 6H). All six wells are currently shut in and not vented. Inspection of the Baker 6H cellar revealed steady rolling bubbling alongside the 9 5/8" casing. It is requested by the DEP that the Operator identify the source of the leak. The Operator is to notify the DEP when this work is to be completed. The Operator shall provide a summary of the findings, and a description fo what repairs need to be completed. According to Chapter 78 Section 78.86...the Operator has the option to correct the defect or submit a plan to correct the defect for approval by the Department within 30 days. |
2053182 | Primary Facility | 2012-03-13 | Routine/Complete Inspection | No Violations Noted | Please refer to Baker 1H 3-13-12 inspection report regarding details of the investigation. Permit number is 115-20471. |
2077201 | Primary Facility | 2012-06-18 | Routine/Complete Inspection | Violation(s) Noted | See inspection report for full details |
2357033 | Primary Facility | 2015-04-01 | Routine/Complete Inspection | No Violations Noted | |
2414166 | Primary Facility | 2015-10-08 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 11:30 a.m., the wells were shut in with a crew working on the production lines, the cellar was about a quarter full of water with no bubbling detected, the (9x5) vent pipe was open and venting to a tank, there was 708psi on the production casing and 664psi on the production line. I took a walk around the site and everything looked OK. |
2451828 | Primary Facility | 2016-01-21 | Routine/Complete Inspection | No Violations Noted | The Department was on site to inspect the Baker well pad (ESX10-115-0029). The wells associated with the pad are as follows:
115-20471 115-20470 115-20469 115-20468 115-20467 115-20466 115-20465 The site was stable and well vegetated with no apparent erosional issues. There were no violations. If there are any issues please feel free to contact me |
2509567 | Primary Facility | 2016-07-28 | Routine/Complete Inspection | No Violations Noted | The Department was on site to inspect the Baker well pad (ESX10-115-0029). The wells associated with the pad are as follows:
115-20471 115-20470 115-20469 115-20468 115-20467 115-20466 115-20465 The site was stable and well vegetated with no apparent erosional issues. There were no violations. If there are any issues please feel free to contact me. |
2511745 | Primary Facility | 2016-08-17 | Site Restoration | No Violations Noted | The Department was on site to conduct a Notice of Termination on the Baker well pad (ESX10-115-0029 (1)). The wells associated with the pad are as follows:
115-20471 115-20470 115-20469 115-20468 115-20467 115-20466 115-20465 The site was rocky, but where there was enough soil for growth, vegetation was meeting or exceeding the 70% vegetative standard. There were a few remaining BMPs (silt sock) and these were promptly removed by Carrizo employees. Off the access road to the Impoundment and Well Site the landowner constructed an earthwork gun range, well vegetated and stable. This is causing no impact to the site or access road. The area was stable and had no erosional issues at this time and it is recommended that this Notice of Termination be APPROVED. There were no violations. If there are any issues please feel free to contact me. |
2512490 | Primary Facility | 2016-08-22 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 13:00p.m., the cellar had water at the bottom with no bubbling noticed; the (9x5) vent pipe was open and venting into a tank. There was 649psi on the production casing and 371psi on the production line. I took a walk around the location and everything looked OK.
I left the site at 13:40p.m. |
2606527 | Primary Facility | 2017-06-21 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 10:35a.m.
The cellar had water at the bottom with no bubbling noticed. The (9x5) annulus vent pipe was open and venting into the production tank. There was 472psi on the production casing and 449psi on the production line. I took a walk around the location and there were no obvious concerns noticed. I left the site at 11:20a.m. |
2713029 | Primary Facility | 2018-03-28 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. The cellar was empty and there was no gas detected. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2817019 | Primary Facility | 2018-12-18 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. The cellar was empty and there was no gas detected with a MSA Altair 5X multi gas detector that was calibrated on 12/3/18. The permit number for the 4H on the entrance sign was incorrect (see photo #2). It was 155-20468 and should be 115-20468. I contacted Jesse Bonnice of BKV to have it corrected. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2851753 | Primary Facility | 2019-03-11 | Routine/Complete Inspection | No Violations Noted | I performed a Routine Complete (RTNC) inspection of the Baker Well Pad on March 11, 2019. The weather was sunny and relatively warm, around 38 degrees.
The access road was a bit muddy but not unstable. The access road is quite long, passing some small logging operations, as well as a target shooting range situated along its length. The well pad surface was plowed and mostly wet but stable. The wellheads were encased in a carport structure. They were surrounded by clean gravel and were properly labeled. The containment surrounding the production tanks and apparatus was mostly empty and had sufficient freeboard. The cut and fill slopes of the site were rocky and stable. Where there was sufficient soil, there was adequate vegetation. No areas of instability were noted. The impoundment on site was full to capacity. It would be recommended to draw down the impoundment to prevent overflow and possible resulting E&S issues. There were no violations noted |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2077201 | 642176 | 06/18/2012 | 2012-06-18 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety | |
2077201 | 642177 | 06/18/2012 | 2012-06-18 | 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | Environmental Health & Safety |
For data sources see[8]