37-115-20469

Well Details

Well ID: 37-115-20469
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Forest Lake Township
Operator Name: BKV OPR LLC
Well Pad ID: 145322
Farm/Lease Name: BAKER 3H
License Status:
Spud Date:
Permit Date: 2010-11-17
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.884131
Longitude: -75.992408

For data sources see[1][2][3]

Well History

Date Event
2010-11-17 New Permit Application
2010-12-01 Performed Spud Operation
2011-05-12 Drilling Completion
2012-04-30 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-12-05 2011-12-05 6,245 6,798,540

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Hydrochloric Acid 5.1-7.5 Baker Hughes Acidizing Water 7732-18-5 92.50 0.02
Hydrochloric acid 7647-01-0 7.50 0.00219000
CI-14 Baker Hughes Corrosion Inhibitor Alkenes, C>10 .alpha.- 64743-02-8 5.00 0.00003000
Propargyl alcohol 107-19-7 5.00 0.00003000
Methanol 67-56-1 100.00 0.00063000
Fatty acids, tall-oil 61790-12-3 10.00 0.00006000
Ethoxylated C14-15 alcohols 68951-67-7 30.00 0.00019000
Scaletrol 720 Baker Hughes Scale Inhibitor Ethylene glycol 107-21-1 45.00 0.00680000
Diethylene glycol 111-46-6 5.00 0.00076000
Alpha 1427 Baker Hughes Biocide Quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides
68424-85-1 7.00 0.00162000
Ethanol 64-17-5 5.00 0.00116000
Glutaraldehyde 111-30-8 30.00 0.00695000
Didecyl dimethyl ammonium chloride 7173-51-5 10.00 0.00232000
Water 7732-18-5 60.00 0.01
InFlo 250W Baker Hughes Surfactant Methanol 67-56-1 30.00 0.00022000
2-Butoxyethanol 111-76-2 20.00 0.00015000
Surfactants 80.00 0.00058000
Ferrotrol 300L Baker Hughes Iron Control Citric acid 77-92-9 60.00 0.00165000
Sand, White, 30/50 Baker Hughes Proppant Quartz 14808-60-7 100.00 5.76
Sand, White, 100 mesh Baker Hughes Proppant Quartz 14808-60-7 100.00 1.49
Sand, White, 40/70 Baker Hughes Proppant Quartz 14808-60-7 100.00 6.73
Water Operator Carrier Water 7732-18-5 100.00 85.48
Additional Ingredients Baker Hughes Surfactant
Additional Ingredients Surfactant Hydrochloric acid 7647-01-0
Water 7732-18-5
Thiourea polymer 68527-49-1
Calcium chloride 10043-52-4
Formalin 50-00-0
2-Propenoic, Polymer with Sodium Phosphinate, Sodium Salt 71050-62-9
FRW-18 Baker Hughes Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.04
Hydrochloric Acid 10.1-15 Baker Hughes Acidizing Hydrochloric acid 7647-01-0 15.00 0.06
Water 7732-18-5 85.00 0.34

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CARRIZO (MARCELLUS) LLC 0.00 0 0.00 0 0.00 0
2011 CARRIZO (MARCELLUS) LLC 12,644.00 5 0.00 0 0.00 0
2012 CARRIZO (MARCELLUS) LLC 1,261,946.00 275 0.00 0 0.00 0
2013 CARRIZO (MARCELLUS) LLC 651,741.00 268 0.00 0 0.00 0
2014 CARRIZO (MARCELLUS) LLC 10,729.68 11 0.00 0 0.00 0
2015 CARRIZO (MARCELLUS) LLC 339,996.63 99 0.00 0 0.00 0
2016 CARRIZO (MARCELLUS) LLC 1,085,158.41 353 0.00 0 0.00 0
2017 CARRIZO (MARCELLUS) LLC 749,931.96 357 0.00 0 0.00 0
2018 BKV OPR LLC 566,820.44 364 0.00 0 0.00 0
2019 BKV OPR LLC 477,157.63 362 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 CARRIZO (MARCELLUS) LLC Drilling Fluid Waste 530.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2011 CARRIZO (MARCELLUS) LLC Drill Cuttings 360.00 Tons LANDFILL THR029
2011 CARRIZO (MARCELLUS) LLC Drill Cuttings 2,098.00 Tons LANDFILL NY STATE #32S11
2011 CARRIZO (MARCELLUS) LLC Produced Fluid 6,969.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CARRIZO (MARCELLUS) LLC Produced Fluid 39,218.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CARRIZO (MARCELLUS) LLC Produced Fluid 1,267.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CARRIZO (MARCELLUS) LLC Produced Fluid 216.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE003
2014 CARRIZO (MARCELLUS) LLC Produced Fluid 147.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2014 CARRIZO (MARCELLUS) LLC Produced Fluid 735.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014 CARRIZO (MARCELLUS) LLC Produced Fluid 805.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 CARRIZO (MARCELLUS) LLC Produced Fluid 49.48 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 CARRIZO (MARCELLUS) LLC Produced Fluid 59.65 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2015 CARRIZO (MARCELLUS) LLC Produced Fluid 14.32 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015 CARRIZO (MARCELLUS) LLC Produced Fluid 124.57 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE003
2015 CARRIZO (MARCELLUS) LLC Produced Fluid 169.66 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CARRIZO (MARCELLUS) LLC Other Oil & Gas Wastes 15.18 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2016 CARRIZO (MARCELLUS) LLC Produced Fluid 256.07 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2016 CARRIZO (MARCELLUS) LLC Produced Fluid 114.97 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2016 CARRIZO (MARCELLUS) LLC Produced Fluid 271.57 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE003
2016 CARRIZO (MARCELLUS) LLC Produced Fluid 255.08 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016 CARRIZO (MARCELLUS) LLC Produced Fluid 634.32 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE003
2016 CARRIZO (MARCELLUS) LLC Produced Fluid 208.95 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2016 CARRIZO (MARCELLUS) LLC Produced Fluid 222.39 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2017 CARRIZO (MARCELLUS) LLC Produced Fluid 149.39 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 CARRIZO (MARCELLUS) LLC Produced Fluid 750.93 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017 CARRIZO (MARCELLUS) LLC Produced Fluid 156.98 Bbl REUSE (AT WELL PAD)
2017 CARRIZO (MARCELLUS) LLC Produced Fluid 449.90 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE003
2017 CARRIZO (MARCELLUS) LLC Produced Fluid 28.99 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 BKV OPR LLC Produced Fluid 15.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE003
2018 CARRIZO (MARCELLUS) LLC Produced Fluid 100.89 Bbl REUSE (AT WELL PAD)
2018 CARRIZO (MARCELLUS) LLC Produced Fluid 366.56 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 BKV OPR LLC Produced Fluid 15.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119
2019 BKV OPR LLC Produced Fluid 271.43 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 BKV OPR LLC Produced Fluid 15.00 Bbl REUSE (AT WELL PAD)
2019 BKV OPR LLC Produced Fluid 75.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE003

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2007322 Primary Facility 2011-09-29 Routine/Complete Inspection No Violations Noted
2014417 Primary Facility 2011-10-25 Routine/Complete Inspection Pending DEP arrived on site at 11 am. The purpose of the inspection was to check the status of the wells and not any activity on site. At the time of inspection, crews were installing new plastic secondary containment for upcoming frac. Six wells have been drilled (1H - 6H). All six wells are currently shut in and not vented. Inspection of the Baker 3H cellar revealed steady bubbling alongside the 9 5/8" casing. Bubbling was also present @ 1' away from well head. Due to the level of fluid in the cellar the source could not be determined. It is requested by the DEP that the Operator identify the source of the leak. The Operator is to notify the DEP when this work is to be completed. The Operator shall provide a summary of the findings, and a description fo what repairs need to be completed. According to Chapter 78 Section 78.86...the Operator has the option to correct the defect or submit a plan to correct the defect for approval by the Department within 30 days.
2053179 Primary Facility 2012-03-13 Routine/Complete Inspection No Violations Noted Please refer to Baker 1H 3-13-12 inspection report regarding details of the investigation. Permit number is 115-20471.
2077195 Primary Facility 2012-06-18 Routine/Complete Inspection Violation(s) Noted See inspection report for full details
2357022 Primary Facility 2015-04-01 Routine/Complete Inspection No Violations Noted
2414141 Primary Facility 2015-10-08 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 11:30 a.m., the wells were shut in with a crew working on the production lines, the cellar had water at the bottom with no bubbling detected, the (9x5) vent pipe was open and venting to a tank, there was 0psi on the production casing and 0psi on the production line. I took a walk around the site and everything looked OK.
2451824 Primary Facility 2016-01-21 Routine/Complete Inspection No Violations Noted The Department was on site to inspect the Baker well pad (ESX10-115-0029). The wells associated with the pad are as follows:

115-20471 115-20470 115-20469 115-20468 115-20467 115-20466 115-20465

The site was stable and well vegetated with no apparent erosional issues. There were no violations.

If there are any issues please feel free to contact me

2509563 Primary Facility 2016-07-28 Routine/Complete Inspection No Violations Noted The Department was on site to inspect the Baker well pad (ESX10-115-0029). The wells associated with the pad are as follows:

115-20471 115-20470 115-20469 115-20468 115-20467 115-20466 115-20465

The site was stable and well vegetated with no apparent erosional issues. There were no violations.

If there are any issues please feel free to contact me.

2511742 Primary Facility 2016-08-17 Site Restoration No Violations Noted The Department was on site to conduct a Notice of Termination on the Baker well pad (ESX10-115-0029 (1)). The wells associated with the pad are as follows:

115-20471 115-20470 115-20469 115-20468 115-20467 115-20466 115-20465

The site was rocky, but where there was enough soil for growth, vegetation was meeting or exceeding the 70% vegetative standard.  There were a few remaining BMPs (silt sock) and these were promptly removed by Carrizo employees.  Off the access road to the Impoundment and Well Site the landowner constructed an earthwork gun range, well vegetated and stable.  This is causing no impact to the site or access road.  
The area was stable and had no erosional issues at this time and it is recommended that this Notice of Termination be APPROVED. 

There were no violations.

If there are any issues please feel free to contact me.

2512480 Primary Facility 2016-08-22 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 13:00p.m., the cellar had water at the bottom with no bubbling noticed; the (9x5) vent pipe was open and venting into a tank. There was 902psi on the production casing and 648psi on the production line. I took a walk around the location and everything looked OK.

I left the site at 13:40p.m.

2606523 Primary Facility 2017-06-21 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 10:35a.m.

The cellar was about half full of water with no bubbling noticed. The (9x5) annulus vent pipe was open and venting into the production tank. There was 556psi on the production casing and 496psi on the production line. I took a walk around the location and there were no obvious concerns noticed. I left the site at 11:20a.m.

2713025 Primary Facility 2018-03-28 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water 3.5' below grade in the cellar with no bubbling noticed and no gas detected in the remainder of the cellar. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2817027 Primary Facility 2018-12-18 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water 4' below grade in the cellar with no bubbling noticed and there was no gas detected in the remainder of the cellar with a MSA Altair 5X multi gas detector that was calibrated on 12/3/18. The permit number for the 4H on the entrance sign was incorrect (see photo #2). It was 155-20468 and should be 115-20468. I contacted Jesse Bonnice of BKV to have it corrected. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2851759 Primary Facility 2019-03-11 Routine/Complete Inspection No Violations Noted I performed a Routine Complete (RTNC) inspection of the Baker Well Pad on March 11, 2019. The weather was sunny and relatively warm, around 38 degrees.

The access road was a bit muddy but not unstable. The access road is quite long, passing some small logging operations, as well as a target shooting range situated along its length.

The well pad surface was plowed and mostly wet but stable. The wellheads were encased in a carport structure. They were surrounded by clean gravel and were properly labeled.

The containment surrounding the production tanks and apparatus was mostly empty and had sufficient freeboard.

The cut and fill slopes of the site were rocky and stable. Where there was sufficient soil, there was adequate vegetation. No areas of instability were noted.

The impoundment on site was full to capacity. It would be recommended to draw down the impoundment to prevent overflow and possible resulting E&S issues.

There were no violations noted

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2077195 642169 06/18/2012 2012-06-18 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. Environmental Health & Safety
2077195 642170 06/18/2012 2012-06-18 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. Environmental Health & Safety

For data sources see[8]