37-115-20474

Well Details

Well ID: 37-115-20474
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Forest Lake Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 148373
Farm/Lease Name: FRASER 8
License Status:
Spud Date:
Permit Date: 2010-11-19
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.864539
Longitude: -75.944828

For data sources see[1][2][3]

Well History

Date Event
2010-11-19 New Permit Application
2011-01-21 Performed Spud Operation
2011-07-05 Drilling Completion
2011-07-20 Perforation
2011-07-20 Performed Stimulation
2011-12-09 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-07-29 2011-07-29 6,199 5,894,364

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FRW-18 BJ Services Company Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.02
CI-14 BJ Services Company Corrosion Inhibitor Propargyl alcohol 5.00 0.00004000
Methanol 67-56-1 68.00 0.00060000
Ferrotrol 300L BJ Services Company Iron Control Product Citric acid 77-92-9 70.00 0.00089000
15 HCl BJ Services Company Acid Package Hydrochloric acid 7647-01-0 15.00 0.08
Water Carrier/Base Fluid 100.00 88.33
Sand (Proppant) Proppant 100.00 11.53
Clay Master-5C BJ Services Company Clay Stabilization No hazardous ingredients 0.00058000
Scaletrol 720 BJ Services Company Scale Inhibitor Diethylene glycol 111-46-6 5.00 0.00052000
Ethylene glycol 107-21-1 35.00 0.00365000
Alpha 1427 BJ Services Company Antibacterial Agent Quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides
68424-85-1 7.00 0.00159000
Didecyl dimethyl ammonium chloride 7173-51-5 10.00 0.00227000
Ethanol 64-17-5 5.00 0.00113000
Glutaraldehyde 111-30-8 30.00 0.00681000

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2011-07-20 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2011 CABOT OIL & GAS CORP 100,949.41 46 0.00 0 0.00 0
2012 CABOT OIL & GAS CORP 609,399.96 363 0.00 0 0.00 0
2013 CABOT OIL & GAS CORP 441,281.80 353 0.00 0 0.00 0
2014 CABOT OIL & GAS CORP 342,343.15 364 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 243,431.60 355 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 281,552.08 366 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 320,179.38 325 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 308,790.00 365 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 263,324.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 CABOT OIL & GAS CORP Fracturing Fluid Waste 26.71 Tons LANDFILL 101534
2011 CABOT OIL & GAS CORP Drilling Fluid Waste 122.53 Bbl REUSE OTHER THAN ROAD SPREADING
2011 CABOT OIL & GAS CORP Drill Cuttings 0.12 Tons LANDFILL 101534
2011 CABOT OIL & GAS CORP Basic Sediment 5.96 Bbl LANDFILL 100081
2011 CABOT OIL & GAS CORP Drill Cuttings 1,298.21 Tons LANDFILL 101247
2011 CABOT OIL & GAS CORP Drill Cuttings 1,056.38 Tons LANDFILL THR029
2011 CABOT OIL & GAS CORP Produced Fluid 2,574.71 Bbl REUSE OTHER THAN ROAD SPREADING
2011 CABOT OIL & GAS CORP Fracturing Fluid Waste 37.19 Tons LANDFILL 100081
2011 CABOT OIL & GAS CORP Drill Cuttings 0.22 Tons LANDFILL 100081
2011 CABOT OIL & GAS CORP Fracing Fluid Waste 22,929.73 Bbl REUSE OTHER THAN ROAD SPREADING
2011 CABOT OIL & GAS CORP Drill Cuttings 46.21 Tons LANDFILL 100945
2012 CABOT OIL & GAS CORP Fracturing Fluid Waste 5.23 Tons LANDFILL 101534
2012 CABOT OIL & GAS CORP Produced Fluid 11,064.67 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CABOT OIL & GAS CORP Basic Sediment 34.49 Bbl LANDFILL THR029
2012 CABOT OIL & GAS CORP Fracturing Fluid Waste 7.04 Tons LANDFILL 100081
2012 CABOT OIL & GAS CORP Fracing Fluid Waste 3,456.59 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CABOT OIL & GAS CORP Fracturing Fluid Waste 75.14 Tons LANDFILL 100945
2012 CABOT OIL & GAS CORP Basic Sediment 36.95 Bbl LANDFILL 100081
2012 CABOT OIL & GAS CORP Basic Sediment 54.99 Bbl LANDFILL 101534
2012 CABOT OIL & GAS CORP Produced Fluid 136.65 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE001
2013 CABOT OIL & GAS CORP Produced Fluid 3,866.50 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE002
2013 CABOT OIL & GAS CORP Produced Fluid 1,133.30 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2013 CABOT OIL & GAS CORP Produced Fluid 73.75 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE001
2013 CABOT OIL & GAS CORP Produced Fluid 15.80 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2014 CABOT OIL & GAS CORP Produced Fluid 3,794.89 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Produced Fluid 24.67 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2015 CABOT OIL & GAS CORP Produced Fluid 1,624.84 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 32.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2016 CABOT OIL & GAS CORP Produced Fluid 859.23 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2016 CABOT OIL & GAS CORP Produced Fluid 1,251.89 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 379.26 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 3,149.88 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017 CABOT OIL & GAS CORP Produced Fluid 42.46 Bbl REUSE (AT WELL PAD)
2017 CABOT OIL & GAS CORP Synthetic Liner Materials 1.09 Tons LANDFILL 101247
2017 CABOT OIL & GAS CORP Waste Water Treatment Sludge 1.22 Tons REUSE (AT WELL PAD)
2017 CABOT OIL & GAS CORP Produced Fluid 476.78 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 54.57 Bbl REUSE (AT WELL PAD)
2018 CABOT OIL & GAS CORP Produced Fluid 1,774.25 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 1,426.42 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018 CABOT OIL & GAS CORP Other Oil & Gas Wastes 0.21 Tons LANDFILL 100933
2019 CABOT OIL & GAS CORP Produced Fluid 2,901.12 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019 CABOT OIL & GAS CORP Produced Fluid 14.06 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1939559 Primary Facility 2010-12-29 Routine/Complete Inspection No Violations Noted
1984087 Primary Facility 2011-06-27 Drilling/Alteration No Violations Noted Pioneer 61. Lost tools in hole. 153.6'. Pin sheared between two collars. Planning to tag top of fish and cement in place. Company man provided copy of Bottom hole assembly. No radioactive source in hole. Drillers log on site and up to date.
2018901 Primary Facility 2011-11-09 Routine/Complete Inspection No Violations Noted DEP on site 11:30. WEll is online. Well tenders on site doing production work. 6" water in cellar. No bubbling observed. WEll tag present. Site id sign present. Vents are open and vented to poly tank. Four other wells drilled and completed on site. 1V (not online), and 3H, 5H and 7H which are online. No violations observed.
2045905 Primary Facility 2012-02-13 Incident- Response to Accident or Event No Violations Noted Violations and specifics associated with this inspection report can be referred to in the Fraser 1 inspection report for 2-13-12. Permit number is 115-20447.
2052584 Primary Facility 2012-03-13 Follow-up Inspection No Violations Noted Violations and specifics associated with this inspection report can be referred to in the Fraser 1 3-13-12 inspection report. Permit number is 115-20447.
2354529 Primary Facility 2015-03-24 Routine/Complete Inspection No Violations Noted
2377273 Primary Facility 2015-06-04 Routine/Complete Inspection No Violations Noted The Department was on site to conduct a routine complete inspection of the erosion and sedimentation controls at the Fraser E. well pad (ESX10-115-0020) on June 4, 2015. The wells associated with this pad are as follows:
2422220 Primary Facility 2015-11-04 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 11:20, the cellar was full of water, the (20x13) vent pipe was open and venting to a tank, the (13x9) vent pipe was open and venting to a tank, the (9x5) vent pipe was open and venting to a tank, there were no pressure gauges on the well, I took a walk around the location and everything looked OK.
2502287 Primary Facility 2016-07-13 Routine/Complete Inspection No Violations Noted The Department was on site to conduct a routine complete inspection of the erosion and sedimentation controls at the Fraser E. well pad (ESX10-115-0020) on June 4, 2015. The wells associated with this pad are as follows:

1V 115-20447 2H 115-20477 3H 115-20473 4H 115-20493 5H 115-20463 7H 115-20464 8H 115-20474

The site was in production, and not under any major construction at this time and the site was very well vegetated (>70%) and graded well. Surrounding the site active agriculture (haying operation) was occurring. There were no erosion and sedimentation issues on site and the access road was holding up well.


There were no violations

If there are any questions please feel free to contact me at (570)346-5539.

2516415 Primary Facility 2016-08-30 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 9:30a.m., the cellar was full of water with no bubbling noticed, the (20x13) vent pipe was open and venting into a tank, the (13x9) vent pipe was open and venting into a tank, the (9x5) vent pipe was open and venting into a tank. There was 471psi on the production casing. I took a walk around the location and everything looked OK.

I left the site at 10:15a.m.

2549893 Primary Facility 2017-01-05 Routine/Complete Inspection No Violations Noted The Department was on site to conduct a routine complete inspection of the erosion and sedimentation controls at the Fraser E. well pad (ESX10-115-0020) on June 4, 2015. The wells associated with this pad are as follows:

1V 115-20447 2H 115-20477 3H 115-20473 4H 115-20493 5H 115-20463 7H 115-20464 8H 115-20474

The site was in production, and not under any major construction at this time and the site was very well vegetated (>70%) and graded well. The vegetation surrounding the site has been mowed, and is in great shape. There were no erosion and sedimentation issues on site and the access road was holding up well.


There were no violations

If there are any questions please feel free to contact me at (570)346-5539.

2568312 Primary Facility 2017-02-23 Routine/Complete Inspection No Violations Noted The Department was on site to conduct a Routine Complete Inspection. This well site's ESCGP permit number is 5809802. I reviewed the E&S Inspection Log to find that Mike Brilla (TEC) conducted the most recent inspection on 2-14-17. He identified it as a post precipitation inspection.
2596338 Primary Facility 2017-05-17 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 10:20a.m.

There was a service crew on site to run 2¿ tubing in the wells to enhance production. I met with company man Jim Restly of Restly Oil & Gas Consulting. The tubing was pulled out of the 1V well and will be run in the 5H well. The 3H well has tubing in it and an additional 300' to 400' will be added. The 7H and 8H wells do not have tubing in them but will have new tubing run in them. The production units are also being refurbished. I took a walk around the location and there were no obvious concerns noticed. I left the site at 11:25a.m.

2703567 Primary Facility 2018-03-06 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was snow and ice 4' below grade in the cellar and was unable to check for gas. The (20x13), (13x9) and (9x5) annuli vent pipes were connected together and going to the same tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2710121 Primary Facility 2018-03-26 Routine/Complete Inspection No Violations Noted I inspected the site on March 26, 2018. The weather was sunny and approximately 40 degrees. The access road was solid and stable. The pad surface was solid and the cut and fill slopes were well vegetated and stable. The wells were labeled clearly. The wells associated with this site were as follows:

115-20447 115-20463 115-20464 115-20473 115-20474 115-20477 115-20493 (plugged)

2740434 Primary Facility 2018-06-12 Routine/Complete Inspection No Violations Noted I performed a RTNC inspection of the Fraser Pad. The wells associated with this are the 115-20447, 115-20463, 115-20464, 115-20473, 115-20474, 115-20477 (plugged), 115-20493 (plugged). The wells were properly labeled.

The access road was solid and stable as was the pad surface. There was no puddling onsite. There did not appear to be any issues of concern with the site stability.

The cut slope as well as the fill slope was stable and well vegetated. They were gently sloped and there did not appear to be any erosional issues.

There were no violations.

2800735 Primary Facility 2018-11-08 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water .5' below grade in the cellar and there was no bubbling noticed. The (20x13), (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was gas detected at the poly vent tank with a MSA Altair 5X multi gas detector that was calibrated on 11/2/18. There were five 55 gallon drums on containment (see photo) marked paint waste, a crew from Covanta Environmental Solutions arrived on site to remove the drums as I was about to leave. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

For data sources see[9]

References