If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-20487 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.831631,"lon":-75.928547,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Jessup Township | |
Operator Name: BKV OPR LLC | |
Well Pad ID: 145337 | |
Farm/Lease Name: BONNICE 1H | |
License Status: | |
Spud Date: | |
Permit Date: 2010-12-20 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.831631 | |
Longitude: -75.928547 |
Date | Event |
---|---|
2010-12-20 | New Permit Application |
2011-05-04 | New Permit Application |
2011-05-06 | Performed Spud Operation |
2011-08-09 | Drilling Completion |
2012-04-30 | DEVIATED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | CARRIZO (MARCELLUS) LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | CARRIZO (MARCELLUS) LLC | 185,110.00 | 46 | 0.00 | 0 | 0.00 | 0 |
2012 | CARRIZO (MARCELLUS) LLC | 1,441,231.00 | 345 | 0.00 | 0 | 0.00 | 0 |
2013 | CARRIZO (MARCELLUS) LLC | 997,624.00 | 353 | 0.00 | 0 | 0.00 | 0 |
2014 | CARRIZO (MARCELLUS) LLC | 686,138.13 | 277 | 0.00 | 0 | 0.00 | 0 |
2015 | CARRIZO (MARCELLUS) LLC | 532,939.09 | 218 | 0.00 | 0 | 0.00 | 0 |
2016 | CARRIZO (MARCELLUS) LLC | 728,250.65 | 293 | 0.00 | 0 | 0.00 | 0 |
2017 | CARRIZO (MARCELLUS) LLC | 785,304.18 | 347 | 0.00 | 0 | 0.00 | 0 |
2018 | BKV OPR LLC | 628,534.93 | 354 | 0.00 | 0 | 0.00 | 0 |
2019 | BKV OPR LLC | 660,288.99 | 363 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | CARRIZO (MARCELLUS) LLC | Drill Cuttings | 316.00 Tons | LANDFILL | NY STATE #32S11 |
2011 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 10,997.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | CARRIZO (MARCELLUS) LLC | Fracturing Fluid Waste | 18.49 Tons | LANDFILL | THR029 |
2012 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 6,263.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 1,463.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 173.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 55.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 703.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 23,800.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 27,020.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | CARRIZO (MARCELLUS) LLC | Basic Sediment | 60.03 Bbl | LANDFILL | THR029 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 850.54 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 587.44 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 324.01 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 986.23 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 2,504.28 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 261.55 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 62.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 205.21 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 495.99 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 109.21 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 267.59 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 311.39 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 562.18 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 1,939.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 87.45 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 367.34 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 389.43 Bbl | REUSE (AT WELL PAD) | |
2018 | BKV OPR LLC | Produced Fluid | 110.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2018 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 417.21 Bbl | REUSE (AT WELL PAD) | |
2018 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 2,128.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2019 | BKV OPR LLC | Produced Fluid | 105.63 Bbl | REUSE (AT WELL PAD) | |
2019 | BKV OPR LLC | Produced Fluid | 665.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2019 | BKV OPR LLC | Produced Fluid | 2,071.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1976928 | Primary Facility | 2011-05-26 | Drilling/Alteration | No Violations Noted | Falcon rig 14. Company man jeff Akers. Drilling depth 750'. Just set 13 3/8" casing to 733'. Bumped plug @ 22:45. float equipment failed - shut in with 250 lbs and let sit for min..8 hours. Ran triple combo log(caliper/resistivity/temp). Drillers log on site and up to date. Observed some residual oil on plastic near fuel tank and compressors - operator to keep area clean. Recommended holsters for fuel nozzles. |
1991591 | Primary Facility | 2011-07-28 | Follow-up Inspection | Viol(s) Noted & Immediately Corrected | HWD#2. On July 26th Emplyee sucking up fluid off containment. Employee shut valve on pump - had 37 gallons flowback through hose onto containment. Spill reported to DEP and cleaned up. Violation immediately corrected. Inspected site. Noted improvements necessary on solids handling. Operator will improve conditions. DEP will follow up. |
2365650 | Primary Facility | 2015-04-29 | Routine/Complete Inspection | No Violations Noted | |
2465388 | Primary Facility | 2016-03-16 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 10:55 a.m., the cellar was full of water with no bubbling noticed, the (9x5) vent pipe was open and venting to a tank, there was 829psi on the production casing and 740psi on the production line. I took a walk around the location and everything looked OK.
I left the site at 11:40 a.m. |
2528702 | Primary Facility | 2016-10-13 | Site Restoration | No Violations Noted | The Department was on site to conduct a Notice of Termination for the Bonnice well pad and impoundment. The wells associated with this site are as follows:
115-20487 115-20488 115-21488
There were no violations. If there are any issues please feel free to contact me. |
2548714 | Primary Facility | 2016-12-22 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 9:15a.m., the cellar was about three quarters full of water and ice with no bubbling noticed, the vent pipe was open and venting into the production tank. There was a 3000psi pressure gauge on the production casing with about 835psi on it, and there was a 2000psi pressure gauge on the production line with about 790psi on it. I took a walk around the location and there were no obvious concerns noticed.
I left the site at 9:55a.m. |
2636375 | Primary Facility | 2017-09-15 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. I took a walk around the location and there were no obvious concerns noticed. |
2744012 | Primary Facility | 2018-06-21 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. There was water 1.5' below grade in the cellar and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2840250 | Primary Facility | 2019-02-14 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. There was water and ice 2' below grade in the cellar and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1991591 | 616514 | 07/28/2011 | 2011-07-28 | 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. | Administrative | Reported spill of 37 gallons of fluid. Operator sucking up water/mud from cellar and containment as part of routine maintenance. Valve shut on vac and residual fluid in hose drained back onto containment. Spill reported and immediately cleaned up. |
For data sources see[7]