Well Details

Well ID: 37-115-20525
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Franklin Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 148544
Farm/Lease Name: HOLLENBECK 4H
License Status:
Spud Date:
Permit Date: 2011-03-02
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 41.917214
Longitude: -75.832653

For data sources see[1][2][3]

Well History

Date Event
2011-03-02 New Permit Application
2011-03-11 Performed Spud Operation
2011-05-08 Drilling Completion
2011-12-08 Perforation
2011-12-08 Performed Stimulation
2012-04-30 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-12-19 2011-12-19 5,751 3,856,121

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 GBW-30 Breaker Halliburton Energy Services Breaker Hemicellulase enzyme 9012-54-8 15.00 0.00017000
Carbohydrates 95.00 0.00109000
FR-66 Friction Reducer Halliburton Energy Services Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.01
Cla-Web Halliburton Energy Services Clay Control
Proprietary 60.00 0.02
BE-9M Halliburton Energy Services Biocide Tri-n-butyl tetradecyl phosphonium chloride 81741-28-8 10.00 0.00104000
Methanol 67-56-1 30.00 0.00311000
SP Breaker Halliburton Energy Services Breaker Sodium persulfate 7775-27-1 100.00 0.00115000
LP-65 Halliburton Energy Services Scale Inhibitor Ammonium chloride 12125-02-9 10.00 0.00375000
Water Carrier/Base Fluid Water 100.00 86.09
WG-36 Gelling Agent Halliburton Energy Services Gel Guar gum 9000-30-0 100.00 0.00165000
Sand- Silica Sand Halliburton Energy Services Proppant Quartz 14808-60-7 100.00 13.71
Hydrochloric Acid Halliburton Energy Services Acid Hydrochloric acid 7647-01-0 30.00 0.13

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2011-12-08 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 XPR RESOURCES LLC 0.00 0 0.00 0 0.00 0
2012 XPR RESOURCES LLC 229,546.54 208 0.00 0 0.00 0
2013 XPR RESOURCES LLC 390,860.44 349 0.00 0 0.00 0
2014 XPR RESOURCES LLC 309,980.69 364 0.00 0 0.00 0
2015 SWN PROD CO LLC 189,396.53 361 0.00 0 0.00 0
2016 SWN PROD CO LLC 268,499.00 366 0.00 0 0.00 0
2017 SWN PROD CO LLC 56,007.00 193 0.00 0 0.00 0
2018 SWN PROD CO LLC 154,273.00 352 0.00 0 0.00 0
2019 SWN PROD CO LLC 107,100.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 XPR RESOURCES LLC Drilling Fluid Waste 58.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2013 XPR RESOURCES LLC Produced Fluid 928.57 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2013 XPR RESOURCES LLC Produced Fluid 298.42 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2013 XPR RESOURCES LLC Produced Fluid 1,323.80 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013 XPR RESOURCES LLC Produced Fluid 1,341.36 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2013 XPR RESOURCES LLC Produced Fluid 918.30 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2013 XPR RESOURCES LLC Produced Fluid 539.61 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2013 XPR RESOURCES LLC Produced Fluid 659.63 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC010
2014 XPR RESOURCES LLC Produced Fluid 348.75 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2014 XPR RESOURCES LLC Produced Fluid 3,303.39 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2014 XPR RESOURCES LLC Produced Fluid 388.33 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014 XPR RESOURCES LLC Produced Fluid 991.35 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 SOUTHWESTERN ENERGY PROD CO Produced Fluid 3,754.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Produced Fluid 2,000.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016 SWN PROD CO LLC Produced Fluid 1,609.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWN PROD CO LLC Other Oil & Gas Wastes 13.75 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Produced Fluid 340.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWN PROD CO LLC Produced Fluid 2,193.25 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Produced Fluid 27.50 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Other Oil & Gas Wastes 40.00 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Produced Fluid 1,128.25 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Other Oil & Gas Wastes 50.36 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Produced Fluid 716.50 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Produced Fluid 415.75 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Other Oil & Gas Wastes 194.40 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 57.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC035
2019 SWN PROD CO LLC Produced Fluid 793.25 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 451.50 Bbl SURFACE IMPOUNDMENT 826342
2019 SWN PROD CO LLC Other Oil & Gas Wastes 5.44 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 30.00 Bbl REUSE (AT WELL PAD)

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1968897 Primary Facility 2011-04-27 Follow-up Inspection Violation(s) Noted H&P 272. Co. Man Glenn Jochum. DEP rec'd call that spill of 5 bbls SOBM onto plastic at approx. 4 am on site. hose over pressured and sprayed mud over top of sand trap below shakers. Rogers on site with vac truck and crews to clean up spill. On fill slope - significant sloughing of soil. Filter sock is overtopped in areas. observed silty runoff flowing into nearby cree. Crews on site with track hoe loading out mud from toe of slope and hauling off location. DEP WQS was Ryan Kelmish notified and will be visiting site later today.
1987347 Primary Facility 2011-07-07 Routine/Complete Inspection No Violations Noted
2005447 Primary Facility 2011-09-15 Routine/Complete Inspection No Violations Noted
2006740 Primary Facility 2011-09-22 Routine/Complete Inspection No Violations Noted
2007689 Primary Facility 2011-09-23 Follow-up Inspection No Violations Noted
2053522 Primary Facility 2012-03-20 Routine/Complete Inspection Pending Inspected current condition and status of well. Well has been completed and fracced. Well is not online yet. Observed minor bubbling on 9 x 13 3/8" annulus. Appears to be quarter size bubble every second. No other bubbling observed at time of this inspection. A Mercer service rig is on site and a small crew or workers. DEP will follow up with Operator on conditions of well.
2066939 Primary Facility 2012-05-10 Drilling/Alteration No Violations Noted At time of inspection, Service Rig on site - set up on 1H - preparing wells for production. Inspected cellar- intermittent bubbling observed outside 9 5/8" casing. ( about every 5 seconds - minor bubbling). Well shut in - no online yet. Pipeline crews working nearby at time of inspection.
2278324 Primary Facility 2014-06-12 Site Restoration Pending Well Site Restoration Report (8000-PM-OOGM0075) submitted with missing information.
2363000 Primary Facility 2015-04-20 Routine/Complete Inspection No Violations Noted
2433867 Primary Facility 2015-12-14 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 11:50 a.m., the cellar was full of gravel, the vent pipe was open and set up with a Taylor plug, there was no gas detected at the perimeter of the cellar, there was 442psi on the production casing and 413psi on the production line. I took a walk around the location and everything looked OK.
2508877 Primary Facility 2016-05-24 Routine/Complete Inspection No Violations Noted Inspection of the Hollenbeck well pad in conjunction with the Snake Creek Gathering Pipeline notice of termination inspection. There were no issues observed on the well pad at the time of the inspection.
2528989 Primary Facility 2016-10-18 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 13:35p.m., the cellar was full of gravel and there was no gas detected at the perimeter of the cellar. The vent pipe was open and set up with a Taylor plug to check for pressure, the valve on the vent line going to the tank was closed. There was 217psi on the production casing and 171psi on the production line. I took a walk around the location and there were no obvious concerns noticed.

I left the site at 14:15p.m.

2619624 Primary Facility 2017-07-25 Routine/Complete Inspection No Violations Noted
2726967 Primary Facility 2018-04-27 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was full of gravel and there was no gas detected at the perimeter of the cellar. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2825826 Primary Facility 2019-01-11 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was shut in at the GPU by a pneumatic valve. The cellar was full of gravel and I was unable to check for gas at the perimeter of the cellar do too the gravel being frozen. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2845372 Primary Facility 2019-02-27 Routine/Complete Inspection No Violations Noted I performed a site inspection of the Hollenbeck well pad on February 27, 2019. The weather was light snow and temperature in the mid 20s.

The well pad was compact and fenced in along the roadside. There was no activity on site during the inspection. The access driveway and well pad surface was frozen hard.

The slopes surrounding the site were all very well covered with last years vegetation in abundance. There were no noted areas of slope failure or slumping.

All wells were properly labeled.

There were no erosional issues noted.

There were no violations noted at the time of inspections.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1968897 609727 04/27/2011 2011-04-27 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. Environmental Health & Safety

For data sources see[9]