X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-115-20574

Well Details

Well ID: 37-115-20574
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: New Milford Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 148800
Farm/Lease Name: LYNCOTT CORPORATION GU 2H
License Status:
Spud Date:
Permit Date: 2011-07-13
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 41.854886
Longitude: -75.747625

For data sources see[1][2][3]

Well History

Date Event
2011-07-13 New Permit Application
2011-08-15 Performed Spud Operation
2011-09-14 Drilling Completion
2012-11-25 Perforation
2012-11-25 Performed Stimulation
2013-05-23 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-11-23 2012-11-23 6,506 4,727,394

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FRA-405 Clearwater International Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 27.50 0.02
Ammonium chloride 12125-02-9 5.00 0.00398000
Ethoxylated C12-16 alcohols 68551-12-2 5.00 0.00398000
Sodium chloride 7647-14-5 7.50 0.00598000
K Bec Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 20.00 0.00285000
Polyethylene glycol 25322-68-3 60.00 0.00856000
Southwestern Energy Water/Produced Water
AI-250 Clearwater International Acid Inhibitor Isopropanol 67-63-0 40.00 0.00079000
2-Butoxyethanol 111-76-2 40.00 0.00079000
Propargyl alcohol 107-19-7 40.00 0.00079000
Southwestern Energy Sand H2O + Disolved Salts 100.00 90.33
Quartz 14808-60-7 100.00 8.76
15 HCl Acid Hydrochloric acid 7647-01-0 15.00 0.11
SI-115 Clearwater International Scale Inhibitor Sodium chloride 7647-14-5 5.00 0.00057000
Phosphonic acid, [[(phosphonomethyl)imino]bis[2,1-ethanediylnitrilobis(methylene)]]tetrakis-,
sodium salt
22042-96-2 20.00 0.00230000

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2012-11-25 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 SOUTHWESTERN ENERGY PROD CO 0.00 0 0.00 0 0.00 0
2012 SOUTHWESTERN ENERGY PROD CO 9,269.00 6 0.00 0 0.00 0
2013 SOUTHWESTERN ENERGY PROD CO 1,317,111.00 362 0.00 0 0.00 0
2014 SOUTHWESTERN ENERGY PROD CO 660,997.00 266 0.00 0 0.00 0
2015 SWN PROD CO LLC 529,289.00 361 0.00 0 0.00 0
2016 SWN PROD CO LLC 340,658.00 366 0.00 0 0.00 0
2017 SWN PROD CO LLC 165,624.00 360 0.00 0 0.00 0
2018 SWN PROD CO LLC 172,723.00 362 0.00 0 0.00 0
2019 SWN PROD CO LLC 176,585.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 SOUTHWESTERN ENERGY PROD CO Drill Cuttings 18.00 Tons LANDFILL THR029
2013 SOUTHWESTERN ENERGY PROD CO Produced Fluid 4,711.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 SOUTHWESTERN ENERGY PROD CO Fracing Fluid Waste 515.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SOUTHWESTERN ENERGY PROD CO Produced Fluid 410.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SWN PROD CO LLC Produced Fluid 609.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Other Oil & Gas Wastes 80.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Produced Fluid 1.67 Bbl LANDFILL 101247
2016 SWN PROD CO LLC Produced Fluid 508.99 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWN PROD CO LLC Other Oil & Gas Wastes 47.28 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Produced Fluid 344.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWN PROD CO LLC Produced Fluid 1,571.72 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Unused Fracturing Fluid Waste 1.24 Tons LANDFILL THR029
2018 SWN PROD CO LLC Produced Fluid 386.55 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Produced Fluid 16.29 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Soil Contaminated by Oil & Gas Related Spills 0.14 Tons RESIDUAL WASTE PROCESSING FACILITY 301333
2018 SWN PROD CO LLC Soil Contaminated by Oil 0.14 Tons RESIDUAL WASTE PROCESSING FACILITY 301333
2018 SWN PROD CO LLC Produced Fluid 82.85 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Other Oil & Gas Wastes 139.97 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 181.28 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Other Oil & Gas Wastes 23.17 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 52.14 Bbl SURFACE IMPOUNDMENT 826342

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2023883 Primary Facility 2011-11-22 Administrative/File Review Violation(s) Noted Failure to submit completion report w/in 30 days of completion.
2030270 Primary Facility 2011-12-07 Routine/Complete Inspection Violation(s) Noted
2367564 Primary Facility 2015-05-01 Routine/Complete Inspection No Violations Noted
2463922 Primary Facility 2016-03-11 Routine/Complete Inspection No Violations Noted
2482550 Primary Facility 2016-05-10 Routine/Complete Inspection No Violations Noted
2485518 Primary Facility 2016-05-18 Routine/Complete Inspection No Violations Noted All wells listed on this inspection report have been drilled and stimulated and appear to be in production. Pad is stable. All slopes appear to be well vegetated and/or rock stabilized. No violations noted.
2497450 Primary Facility 2016-06-30 Routine/Complete Inspection No Violations Noted
2540081 Primary Facility 2016-11-22 Routine/Complete Inspection No Violations Noted On 11/22/16, the Department conducted an inspection of the SWN RU 18 Lyncott Corp Pad as part of an investigation into a complaint that a nearby water supply may have been affected by natural gas drilling operations. During the inspection it appeared as if all 7 wells (1H, 2H, 3H, 4H, 5H, 6H, and 7H) present were in production. The last well drilled and stimulated on this site is the 7H with drilling having been completed on 2/3/14 and stimulation having been completed on 5/31/14. In general, the pad appeared to be stable with no violations noted.
2576716 Primary Facility 2017-03-27 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 10:20a.m.

The cellar was full of water with no bubbling noticed and there was containment around the well, the containment appeared to be in good condition. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure with a Crystal pressure gauge, the valve going to the production tank was closed. There was 672psi on the production casing and 572psi on the production line. There was a 500bbl flow back tank on containment and the containment appeared to be in good condition. I took a walk around the location and there were no obvious concerns noticed. I left the site at 11:15a.m.

2669940 Primary Facility 2017-12-12 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was shut in at the main valve after the GPU where the line comes out and goes to the gas line. The (20x13) and (13x9) annuli were below the water level and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2771175 Primary Facility 2018-09-04 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water 3' below grade in the cellar with no bubbling noticed and there was no gas detected in the remainder of the cellar. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2023883 626042 11/22/2011 2011-11-22 212WELLRCD - Failure to submit well record within 30 days of completion of drilling Administrative
2030270 628137 12/07/2011 2011-12-07 205B - Drilling w/in 100 ft of surface water or wetland w/o variance Administrative Well site is within 100 ft of an UNT to Meylert Creek (HQ).
2030270 628138 12/07/2011 2011-12-07 102.4INADPLN - E&S Plan not adequate Administrative Plan does not incorporate ABACT for HQ watershed.
2030270 628139 12/07/2011 2011-12-07 102.4HQBMP - Failure to implement Special Protection BMPs for HQ or EV stream. Administrative No ABACT controls including a tirewash rack is incorporated into the E&S Plan nor installed.
2030270 628141 12/07/2011 2011-12-07 102.11 - Failure to design, implement or maintain BMPs to minimize the potential for accelerated erosion and sedimentation. Administrative Failed to incorporate and install ABACT controls in a HQ watershed.

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
626042 278004 NOV - Notice of Violation Administrative Close Out 2012-12-26

For data sources see[9]

References